EN - 17
ABIPLAS
®
WELD 250 MT
9 Maintenance and cleaning
9.1 Torch body
1
Remove gas nozzle.
2
Remove welding spatter.
3
Check wear parts for visible damage and replace them, if required.
4
Unscrew back cap and remove tungsten electrode.
5
Sharpen tungsten electrode as follows:
Sharpening the tungsten electrode depends on wear and must therefore be
carried out when required.
To sharpen the tungsten electrode, use a sharpening device with a diamond
wheel and the following functional principles:
• The point is sharpened longitudinally through the center axis.
• Automatic regulation of the tungsten electrode drive by gravity.
• Can be set for all electrode diameters.
• Offers continuous adjustment of the angle.
9.2 Cable assembly
Clean the cable assembly by proceeding as follows:
1
Check screwings and plug-type connections for visible damage and tight fit
and replace them, if necessary.
NOTE
• Replace the centering ceramics as soon as deposits become visible on
the surface. Deposits may result in a catastrophic high-voltage arc,
destroying the torch body.
Fig. 8
Sharpening the tungsten electrode