EN - 7
ABIMIG
®
WT
4 Putting into operation
Equip the torch neck according to the following figure:
1
Screw the replaceable tip adaptor
(refers to
ABIMIG
®
240D/401D/501D WT).
The following steps refer to all torch types.
2
Screw gas diffuser
3
Screw the contact tip
into the tip adaptor
and tighten contact tip
using a multiple wrench.
4
Slide the gas nozzle
on the torch neck rotating it slightly clockwise.
4.2 Mounting the wire guide
4.2.1 Liner
To be used for steel wires.
1
Unscrew torch neck from handle.
2
Disconnect cable assembly on machine side and lay it down straight.
1
Gas nozzle
2
Contact tip
3
Gas diffuser
4
Tip adaptor
5
Torch neck
Fig. 1
Equipping the torch
ABIMIG
®
401/501 WT/240/401/501 D WT
1
2
3
4
5
ABIMIG
®
401/501 WT
ABIMIG
®
240/401/
501D WT
NOTICE
• Only use gas-tight, plastic-insulated wire guides to ensure a secure
shielding gas cover and a defined current contact.
• Bare liners give rise to a loss of shielding gas.
NOTICE
• New still unused spiral liners or PA liners have to be shortened to the
actual length of the hose assembly.
• To install the wire guide with a little preload, excess length required.