3.1 Technical Data
Welding
- 10 °C to + 40 ° C
Transport and storage
- 25 °C to + 55 ° C
Relative humidity
Up to 90 % at 20 ° C
Tab. 1
Ambient conditions during operation
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN ISO 14175)
CO
2
and mixed gas M21
Wire types
Commercially available round wires
Voltage rating
113 V peak value
Protection type of the machine side
connections (EN 60 529)
IP3X
Type of use
Manual
Control device in handle
For 42 V and 0.1 to 1 A
Tab. 2
General torch data according to EN 60 974-7
Type
Type of
cooling
Load
1
ED
Wire
Gas flow
Cooling
Flow
pressure
Double
circuit
CO
2
M21
Max. supply
temp.
Min.
flow
min. max.
ABIMIG
®
GRIP W
A
A
%
mm
l/min
°C
l/min
bar
bar
555 D
liquid
550
500
100 0.8 - 1.6
10 - 20
40
1.15
2.5
3.5
555
liquid
575
525
100 0.8 - 1.6
10 - 20
40
1.15
2.5
3.5
605 D
liquid
600
550
100 1.0 - 1.6
10 - 20
40
1.15
2.5
3.5
605 C
liquid
600
550
100 1.0 - 1.6
10 - 20
40
1.15
2.5
3.5
605
liquid
625
575
100 1.0 - 1.6
10 - 20
40
1.15
2.5
3.5
Tab. 3
Product-specific torch data (EN 60 974-7)
ABIMIG
®
GRIP W
1For puls arcs, the load data are reduced by up to 30%
Standard length L
3.00 m, 4.00 m, 5.00 m
Coolant connection
Plug-in nipple NW 5
Cooling unit power
Min. 800 W
Control lead
2-wire
Tab. 4
Cable assembly