1-1/8
9/16
5/32
13/16
1-5/8
1-1/8
2-1/4
C
L OF DOOR
DRILL 1-1/8" D. TO INTERSECT 2-1/8" D HOLE
(2) #8 F.H.W.S. OR 8-32 F.H.M.S.
L
C
L
C
2-1/8" D. DR. THRU
1/2 DOOR
EDGE OF STOP
(OR SILENCER)
CL OF
1/32
9/16
2-1/8
1
2-1/8
2-3/4
9/16
1-1/8
1-5/16
5/64
3/8
1/4
1/4
3/8
3/32
3-1/4
4-3/4
4-1/8
1"
4-1/8
4-7/8
3-3/8
1-1/2
15/16
1/32
(2) TAP
(2) DRILL FOR
#8 SCREW
1-1/4
1-1/4
2-1/2
LATCH
1-7/16
DOOR PREP
1. Install door
2. Locate horizontal centerline on door
3. Verify backset (2-3/4", 3-3/4", 5"or 7").
FRAME PREP
1. Mark centerline of latch bolt on frame
2. Center strike and mark screw positions
3. Mortise to required strike and box depth
ASA STRIKE & BOX
STANDARD STRIKE & BOX
#12-24
THICKNESS
BACKSET
REVISED 09-16-14
6100-2-07.DWG
R
O
www.abhmfg.com
E-mail: [email protected]
Architectural Builders Hardware Mfg., Inc.
1222 Ardmore Ave., Itasca, IL 60143
630.875.9900; FAX 800.9FAXABH (932.9224)
c 2014 ABH Mfg., Inc.
printed in USA
FINISHED FLOOR
ADA
RECOMMENDED
HEIGHT 44" FROM
FINISHED FLOOR
-OR-
CHECK LOCAL ORDINANCE
FOR PROPER HEIGHT
PAGE 2 OF 2
6100
OF
DEPTH
BACK SET
3-3/4"
2-3/4"
5"
7"
8-5/8"
6-5/8"
4-3/8"
5-3/8"
BORE