background image

1-1/8

9/16

5/32

13/16

1-5/8

1-1/8

2-1/4

C

L OF DOOR

DRILL 1-1/8" D. TO INTERSECT  2-1/8" D HOLE

(2) #8 F.H.W.S. OR 8-32 F.H.M.S.

L

C

L

C

2-1/8" D. DR. THRU

1/2 DOOR

EDGE OF STOP

(OR SILENCER)

CL OF

1/32

9/16

2-1/8

1

2-1/8

2-3/4

9/16

1-1/8

1-5/16

5/64

3/8

1/4

1/4

3/8

3/32

3-1/4

4-3/4

4-1/8

1"

4-1/8

4-7/8

3-3/8

1-1/2

15/16

1/32

(2) TAP

(2) DRILL FOR

#8 SCREW

1-1/4

1-1/4

2-1/2

LATCH

1-7/16

DOOR PREP

1. Install door

2. Locate horizontal centerline on door
3. Verify backset (2-3/4", 3-3/4", 5"or 7"). 

FRAME PREP

1. Mark centerline of latch bolt on frame

2. Center strike and mark screw positions
3. Mortise to required strike and box depth

ASA STRIKE & BOX

STANDARD STRIKE & BOX

#12-24

THICKNESS

BACKSET

REVISED  09-16-14

6100-2-07.DWG

R

O

www.abhmfg.com

E-mail:  [email protected]

Architectural Builders Hardware Mfg., Inc.

1222 Ardmore Ave., Itasca, IL 60143

630.875.9900;  FAX 800.9FAXABH  (932.9224)

c  2014 ABH Mfg., Inc.
printed in USA

FINISHED FLOOR

ADA

RECOMMENDED

HEIGHT 44" FROM

FINISHED FLOOR

-OR-

CHECK LOCAL ORDINANCE

FOR PROPER HEIGHT

PAGE 2 OF 2

6100

OF

DEPTH

BACK SET

3-3/4"

2-3/4"

5"
7"

8-5/8"

6-5/8"

4-3/8"
5-3/8"

BORE