background image

6.1 

Electrical Connection

§

The stove is equipped with the power supply cable that needs to 
be connected to the mains 230V/50Hz

§

The average power consumption is ± 20W during operation and 
300 W in the ignition phase for about 10 minutes.

§

The power cable must be laid so to avoid contact with the hot 
stove surfaces.

6.2 

Combustion Air

6.3 

Supply of fresh air for combustion

§

The stove structure has a connection on the back side

§

The fresh air supply pipes may be made of steel or aluminium. 
The minimum diameter amounts to 50 mm.

§

The maximum pipe length shall not exceed 4 m in order to ensure 
adequate supply of fresh air. The pipes must not have too many 
elbows.

§

A failure to provide some of the specified conditions may result in 
poor combustion and vacuum generation in a room

Safety distances from the stove

§

The distance between the flammable objects and front part of the 
stove must be up to 800mm, while the distance between the stove 
side walls and flammable objects must be up to 200mm

§

The distance between the non-flammable objects and front part of 
the stove must be up to 400mm, while the distance between the 
stove side walls and non-flammable objects must be up to 100mm

7

      Every combustion process requires oxygen or air. The air taken 
from the room must be compensated. The loss of oxygen may occur 
in modern houses with high insulation efficiency and perfectly sealed 
windows and doors. Unless the stove is connected to fresh air intake, 
the room in which the stove is installed must be more frequently 
ventilated.

Содержание 9kW LILLY

Страница 1: ...USER MANUAL 9kW LILLYPELLETSTOVE...

Страница 2: ...Speci cation 5 5 Technology 6 6 Installation 6 7 Function Operations 8 8 User Menu 10 9 Maintenance and Cleaning 12 10 Environmental Protection 15 11 Appendix 16 Table of Contents ABC PROIZVOD D O O M...

Страница 3: ...1 OVERVIEW OF STOVE PARTS 1...

Страница 4: ...ssembly of sheets behind the rebox Hoper Top rebox outlet Bottom rebox outlet Top burner outlet Top outlet Ribbed outlet Stove door Burner holder Burner Front vermiculite plate left Back vermiculite p...

Страница 5: ...Characteristics Thermal power kWh kg Length mm Diameter mm Humidity Ash 3 Speci c weight kg dm Flue pipe diameter mm Pellet consumption min max Electricity consumption Ignition phase W Operation phas...

Страница 6: ...and explosive materials in the same room when the stove is operating When operating the stove must be connected to the mains voltage 230V Should unexpected power failures occur install the UPS that w...

Страница 7: ...d standards for pellet quality are NORM DIN Plus or ENplus A1 Speci cation of wooden pellets in accordance with En plus A1 5 Parameter Diameter Length Bulk density Calori c value Water content Ash res...

Страница 8: ...on of hazardous substances into atmosphere The top quality cast parts such as burner resistant up to 1300 and doors ensure long and safe operation 6 INSTALLATION Remove all accessories from the stove...

Страница 9: ...ws A failure to provide some of the speci ed conditions may result in poor combustion and vacuum generation in a room Safety distances from the stove The distance between the ammable objects and front...

Страница 10: ...ed lampice P1 P2 P3 P4 Buttons Function ON OFF alarm reset exit from the menu Menu data storage chrono option activation Visualisation increased parameter values Visualisation decreased parameter valu...

Страница 11: ...s Shutting down due to the high temperature of exhaust gases Pellet safety thermostat Encoder error in case that P25 1ili2 Encoder error failed fan control Date and time are not up to date due the pow...

Страница 12: ...of pellet power 8 2 Chrono The Chrono option is used to activate and set time for the system start and shutdown 8 3 Time ON OFF Settings Chrono Select a day of the week and set the ON OFF time in the...

Страница 13: ...to if the set pellet power is 4 This procedure results in the pellet power between 4 and 5 If you increase the Auger calibration set the Fun calibration to the same degree 8 5 Remote controler Button...

Страница 14: ...stove operation 9 CLEANING AND MAINTENANCE 9 1 Basic Information The stove must be off and completely cooled before starting any cleaning and maintenance activity The stove cleaning and maintenance i...

Страница 15: ...with a wet cloth without applying chemical agents containing corrosive acids given the fact that there is a risk of damaging glass surface 9 4 Firebox cleaning The ue ducts located on the left and rig...

Страница 16: ...for cleaning 2 Vacuum clean accumulated dust from the fan case taking care not to damage the propellers 3 Return all parts in place in a reverse order 9 6 Cleaning of ue pipes It is necessary to peri...

Страница 17: ...condary raw materials The adequate storage of this product will prevent the potential adverse impacts on environment and health of people which could otherwise be caused by inappropriate waste handlin...

Страница 18: ...ts Directive 89 106 EEC as well as the following harmonized standard EN 14785 In 2007 ABC PROIZVOD doo U ice implemented the quality management system SRPS ISO 9001 2008 which is maintained and improv...

Страница 19: ......

Отзывы: