6.1
Electrical Connection
§
The stove is equipped with the power supply cable that needs to
be connected to the mains 230V/50Hz
§
The average power consumption is ± 20W during operation and
300 W in the ignition phase for about 10 minutes.
§
The power cable must be laid so to avoid contact with the hot
stove surfaces.
6.2
Combustion Air
6.3
Supply of fresh air for combustion
§
The stove structure has a connection on the back side
§
The fresh air supply pipes may be made of steel or aluminium.
The minimum diameter amounts to 50 mm.
§
The maximum pipe length shall not exceed 4 m in order to ensure
adequate supply of fresh air. The pipes must not have too many
elbows.
§
A failure to provide some of the specified conditions may result in
poor combustion and vacuum generation in a room
Safety distances from the stove
§
The distance between the flammable objects and front part of the
stove must be up to 800mm, while the distance between the stove
side walls and flammable objects must be up to 200mm
§
The distance between the non-flammable objects and front part of
the stove must be up to 400mm, while the distance between the
stove side walls and non-flammable objects must be up to 100mm
7
Every combustion process requires oxygen or air. The air taken
from the room must be compensated. The loss of oxygen may occur
in modern houses with high insulation efficiency and perfectly sealed
windows and doors. Unless the stove is connected to fresh air intake,
the room in which the stove is installed must be more frequently
ventilated.