ABBRA INSTALLATION GUIDE Version.04 4/12/17 

29 

D4. Flood Zone 

A  flood  zone  is  permanently  active  (a  flood  alarm  is 
triggered  regardless  of  whether  the  system  is  armed  or 
disarmed).  Upon  detection  of  flood  leak,  the  event  is 
reported via the telephone line.  

D5. Gas Zone 

A gas zone is permanently active (a gas alarm is triggered 
regardless of whether the system is armed or disarmed). 
Upon detection of gas leak, the event is reported via the 

telephone line

D6. Interior Zone 

Interior  zone  is  a  zone  inside  the protected site. When an 
intruder  enters  to  such  a  zone  an  immediate  alarm  is 
initiated. 

D7. Interior Follower Zones 

A  non-entry/exit  zone, typically an interior zone located on 
an  entry/exit  path  that  is  treated  as  an  entry/exit  zone 
during an entry/exit time. 

D8. Non-Alarm Zones 

A non-alarm zone does not directly participate in the alarm 
system. Its main use is to perform auxiliary remote control 
tasks 

such 

as 

opening/closing 

gate, 

activating/deactivating 

courtesy 

light 

and 

similar 

applications.  No  alarm,  silent  or  otherwise,  is  associated 
with a non-alarm zone.  
For remote control of electrical devices, you can define the 
desired  number  of  non-alarm  zones  and  enroll  a  portable 
transmitter  or  a  wireless  device  (detector)  to  this  type  of 
zone.  Then,  you  must  ensure  that  these  zones  are 
permitted  to  control  the  PGM  output,  or  the  X-10  units  or 
both  (see  par.  4.7).  Next,  you  can  select  the  zones  (3  at 
most) that will control each output. The outputs, in turn, will 
control the external electrical devices.  

Note:

 A device control can also be carried out by holders 

of all keyfob transmitters, by pressing the AUX [

ϕ

] button.  

This  method  will  work provided that you programmed the 
[

ϕ

]  button  for  PGM/X-10  control  (see  Para.  4.4.17),  and 

that you programmed the PGM output and the X-10 units 
to be controlled by keyfob transmitters (see par. 4.7). 

D9. Perimeter Zones 

Perimeter  zones  rely  on  detectors  designed  to  protect 
doors, windows and walls. An immediate alarm is  initiated 
when such a zone is violated  by opening the door/window 
or by trying to break the wall. 

D10. Perimeter Follower Zones 

A non-entry/exit zone, typically a perimeter zone located on 
an  entry/exit  path,  that  is  treated  as  an  entry/exit  zone 
during an entry/exit time. 

D11. 24-Hour Zones 

24  hour  zones  are  mainly  used  for  PANIC  buttons, 
perimeter  detectors  and  anti-tamper  protection.  They 
therefore  trigger  an  alarm  in  both  armed  and  disarmed 
states.  

 

24  Hour  Zone  -  Silent.

  -  Upon  detection,  this  zone 

initiates  a  silent  alarm,  meaning  that  the  sirens  do  not 
function. Instead the Abbra dials telephone numbers and 
reports  the  event  to  central  stations  and/or  to  private 
telephones, as programmed. 

 

24  Hour  Zone  -  Audible.

  -  Upon  detection,  this  zone 

initiates  a  siren  alarm.  The  Abbra  also  dials  telephone 
numbers and  reports the event to central stations and/or 
to private telephones, as programmed. 

 

APPENDIX E. Abbra Compatible Devices 

E1. Abbra

 

Compatible Detectors 

Each detector compatible with the Abbra system is packed 
with  its  own  installation  instructions.  Read  them  carefully 
and install as indicated. 

A. PIR Motion Detectors 

The wireless passive infrared (PIR) motion detectors used 
in  the  system  are  of  the  PowerCode  type.  The  Abbra  is 
capable  of  “learning”  each  detector’s  identification  code 
and linking it to a specific zone (see par. 4.3 in this Guide). 
Some units are shown below:  

 

<Next>

®

  

K9-85 MCW

 

 

 MCPIR-3000 

or K-940 MCW

 

 

DISCOVERY 

K9-80/MCW

 

MCPIR-3000 is not UL-listed! 

Note:

 K-940 MCW,  Discovery K9-80/MCW and <Next>

®

 

K9-85 MCW are pet immune units. 

In  addition  to  its  unique  24-bit  identification  code,  each 
detector 

transmits 

message, 

containing 

status 

information: 

  The detector is in alarm (or not). 

  The detector is being tampered with (or not).  

  The battery voltage is low (or normal). 

  “This is a supervisory message”. 

If  any  of  these  detectors  detects  motion,  it  sends  out  a 
message to the alarm control panel. If the system is in the 
armed state, an alarm will be triggered. 

B. Magnetic Contact Transmitter

 

MCT-302  is  a  PowerCode  magnetic-
contact  transmitter  used  to  detect  the 
opening of a  door or a window.

 

The alarm 

contacts are closed as

 

long as  the door or 

window remains

 

closed. 

 

MCT-302

 

The  unit  has  an  extra  alarm  input  that  acts  as  if it were a 
separate wireless transmitter. It sends (or does not send) a 
“restored  to  normal“  message  to  the  alarm  system, 
depending on the setting of an on-board “DIP” switch. The 
“restore” message informs you, through the control panel’s 
display, whether the door or window is open or closed. 

C.  MCT-100  Wireless  Adapter  for  Wired 

Detectors

 

(not UL-Listed)

 MCT-100 is a PowerCode 

device  used  mainly  as  a  wireless  adapter 
for 2 regular magnetic switches installed on 
2  windows  in  the  same  room.  It  has  two 
inputs,  behaving  as  separate  wireless 
transmitters with different PowerCode IDs. 
Each  input  sends  (or  does  not  send)  a 
“restored“  message  to  the  alarm  system, 

 

Содержание Fully Supervised Wireless Alarm Control System

Страница 1: ...eliminary Guidance 11 4 4 2 Entry Delays 1 2 11 4 4 3 Exit Delay 11 4 4 4 Bell Time 11 4 4 5 Abort Time 11 4 4 6 Alarm Cancel 11 4 4 7 Quick Arm 12 4 4 8 Bypass 12 4 4 9 Exit Mode 12 4 4 10 Piezo Beeps 12 4 4 11 Trouble Beeps 12 4 4 12 Panic Alarm 12 4 4 13 Swinger Stop 12 4 4 14 Cross Zoning 12 4 4 15 Supervision 12 4 4 16 NOT READY 12 4 4 17 AUX Button 12 4 4 18 Jam Detect 12 4 4 19 Latchkey 12 ...

Страница 2: ...to the master user after testing the system Appendices A 1 and A 2 will help you prepare an installation plan Please take time to fill out the forms your job will become much easier and confusion will be prevented Filling out the forms will also help you create a list of detectors and transmitters that must be obtained for the particular application Compatible detectors and transmitters are listed...

Страница 3: ...arm in accordance with zone attributes Siren Signals Continuous intrusion 24 hours panic triple pulse pause triple pulse fire Siren bell Timeout Programmable 4 min by default Internal Sounder Output At least 85 dBA at 10 ft 3 m Supervision Programmable time frame for inactivity alert Special Functions Speech and sound control Powerline Carrier Device Control up to fifteen X 10 brand units by vario...

Страница 4: ... to Pager PIN No èAlarm Type èZone No 2 5 Physical Properties Operating Temp Range 32 F to 120 F 0 C to 49 C Storage Temp Range 4 F to 140 F 20 C to 60 C Humidity 85 relative humidity 30 C 86 F Size 10 13 16 x 8 x 2 1 8 in 275 x 203 x 55 mm Weight 990g 2 2 pounds without batteries Color Ivory and charcoal gray 3 INSTALLATION 3 1 Unpacking the Equipment Open the cardboard packing box and check whet...

Страница 5: ...INSTALLATION GUIDE Version 04 4 12 17 5 Figure 3 1 Backup Battery Installation Open cover 1 Keypad cover 2 Remove screw and open battery compatment Remove screw to release wall mount bracket Connect battery 3 ...

Страница 6: ...6 ABBRA INSTALLATION Figure 3 2 Mounting the Control Panel ...

Страница 7: ...eries has simple phone X 10 and AC power jacks pre installed No power or phone wiring is required simply plug the AC power cord into the AC power jack the phone cord into the telephone jack and the X 10 cord into the X 10 jack as applicable This schematic is provided for reference and for use in hard wiring sensors to zones 29 and 30 ...

Страница 8: ...o 1 3 8 Connecting Abbra to Computer The control panel can be equipped with an optional RS232 module for serial data interchange with a local computer If this module is not supplied a special plastic cap blocks the niche designed to accommodate the module RJ 45 or RJ 31X USA 1 Remove plastic cap Insert the RS 232 adapter into its male connector until a click is heard 2 Figure 3 4 Connecting the Ab...

Страница 9: ...ireless siren Before beginning gather all the devices that you intend to enroll and make sure they all have batteries installed Your control panel must recognize the unique identification code ID of each such device in order to supervise them receive their signals and respond accordingly Attention CodeSecure transmitters are mainly used for arming disarming and can not be enrolled to zones For enr...

Страница 10: ...nrolling action NEXT OK ENROL WL SIREN NEXT WL siren No 1 or 2 e g 2 SIREN No siren No 2 siren No 2 OK OK OFF TO DELETE Momentarily press the wireless siren self test button until a squawk is heard 1 sec approx TRANSMIT NOW Enrolling a wireless siren siren No 2 for next enrolling action NEXT Deleting a wireless siren siren No 2 A W A Y 2way kp No 2 Deleting a wireless keypad MKP 150 Press MKP 150 ...

Страница 11: ...olumns even before you start and proceed to program according to your own list Remember A delay zone is also a perimeter zone by definition Zone types are fully explained in Appendix D For UL installations hard wired zones are not intended to be used as FIRE zones Selectable Zone Names Dining room Downstairs Emergency Fire Front door Garage Garage door Guest room Hall Kitchen Laundry room Lving ro...

Страница 12: ...ring which the beeping rate increases Locations No 1 entry delay 1 and 2 entry delay 2 allow you to program the length of these delays Available options for each delay are 00s 15s 30s 45s 60s 3m and 4m In UL installations these delays must be 45 s max 4 4 3 Exit Delay fig 4 4 location 03 An exit delay allows the user to arm the system and leave the protected site via specific routes and doors with...

Страница 13: ...urs after having been bypassed if the system remains armed The available options are shut after 1 shut after 2 shut after 3 and no shutdown In UL installations No Shutdown must be selected 4 4 14 Cross Zoning fig 4 4 location 14 Do not use in UL installations Here you determine whether cross zoning will be active or inactive Cross zoning is a method used to counteract false alarms an alarm will no...

Страница 14: ...ated The available options are enable and disable 4 4 28 Disarm Option fig 4 4 location 28 Here you determine when it is possible to disarm the system A Any time B During entry delay by using the Abbra keypad or wireless device keyfob C During entry delay byusing a wirelessdevice keyfob only D During entry delay or by using the PowerMax keypad in AWAY mode Options any time on entry all on entry wi...

Страница 15: ... entry dly1 30 s entry dly1 45 s entry dly1 60 s entry dly1 3 m entry dly1 4 m abort time 00 s abort time 15 s abort time 30 s abort time 45 s abort time 60 s abort time 2 m abort time 3 m restart exit off by door normal NEXT OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK bell time 3 m NEXT NEXT abort time 4 m NEXT OK NEXT Note The currently saved options are displayed with dark box at t...

Страница 16: ...waits 5 seconds F 5 Not applicable in phone numbers To enter a series of digits use the following keys Numeric keypad to enter the number Next Item moves the cursor from left to right Back moves the cursor from right to left Off deletes everything after the cursor to the right 4 5 1 Autotest Time fig 4 5 location 01 Here you determine the time at which the telephone line will be tested and reporte...

Страница 17: ...the pager s address The paging company s computer needs this input for routing messages to the specific pager The PIN sequence precedes any digital message that the Abbra sends to the pager to report an event It may include digits pauses and special characters or Call the paging company to find out what the pager s PIN code should consist of Important In this location special characters can be ent...

Страница 18: ...stalled or not installed Available options are installed or not installed 4 6 2 1st 2nd 3rd 4th SMS Number Here you define the first second third and fourth SMS phone number including area code 16 digits maximum to which pre selected events types see next paragraph will be reported 4 6 3 Reporting to SMS Phone Number Here you determine the types of events that will be reported to the pre selected ...

Страница 19: ... 3 Defining INT STRB Here you determine if the INT output will be used for an internal siren or for a strobe 4 7 4 X 10 GENERAL DEF Not evaluated by UL For X 10 devices you can select the following actions n FLASH ON ALARM you can select no flash or all light flash to control X 10 lighting devices in alarm conditions n TRBL INDICATION you can select don t indicate or indicate for X 10 failure indi...

Страница 20: ...T PGM NEXT PGM NEXT Dxx BY ARM AWAY Dxx BY ARM HOME Dxx BY MEMORY OK ONE WAY UNIT PLEASE WAIT test fail test OK NEXT TWO WAY UNIT OK OK OK OK to Enroll enroll OK Enroll FAIL enroll fail HOME Exit X 10 Learn mode OK OK Exit Learn Mode PLEASE WAIT OK to test OFF to Delete if already enrolled Turn X 10 to Learn mode NEXT OK OK pulse time 2s pulse time 30s pulse time 4m pulse time 2m Dxx PULSE TIME PG...

Страница 21: ...ee fig 4 3 The recording process is shown below NEXT OK HOUSE IDENTITY 8 RECORD SPEECH see figure 4 1a USER 5 NAME NEXT USER 6 NAME NEXT USER 7 NAME NEXT USER 8 NAME RECORDING ENDED TALK NOW RECORD A MESSAGE e g John s house NEXT RECORD MESSAGE is displayed momentarily The dark square boxes slowly disappear one by one until end of recording time To check the recorded message press the key and list...

Страница 22: ...em does not recognize your installer code this indicates you must have programmed a user code that is identical with your installer code If so access the user menu and change the code that is identical with your installer code This will re validate your installer code 4 11 RETRIEVING FACTORY DEFAULTS If you want to reset the Abbra parameters to the factory default parameters you should enter the i...

Страница 23: ...roper function of all detectors in the system a comprehensive diagnostic test is required To perform this test refer to figure 4 9 5 3 Keyfob Transmitter Test Initiate transmission from each transmitter enrolled as a keyfob unit according to the list in Table A2 Appendix A Use each transmitter to arm the control panel AWAY and immediately disarm it Upon pressing the keyfob unit s AWAY key the ARM ...

Страница 24: ...ttery pack correct insertion and tightened battery compartment lid the TROUBLE indicator should extinguish However the MEMORY message will now blink in the display caused by the tamper alarm you triggered when opening the battery compartment lid Clear it by arming the system and immediately disarming 6 3 Fuse Replacement The Abbra has two internal fuses that have automatic reset Therefore there is...

Страница 25: ...Ψ 11 Gas Ψ 12 Flood Ψ 13 Interior Zone Locations Note down the intended location for each detector When programming you may select one of 26 available zone names plus 5 custom zone names that you can add see Figure 4 3 Define Zones Zones 29 30 only are hardwired zones A2 Keyfob Transmitter List Transmitter Data AUX button Assignments No Type Holder Status or Arming instant PGM Control X 10 Unit Co...

Страница 26: ...List Tx Transmitter Type Enrolled to Zone Name of holder Assignment 1 2 3 4 5 6 7 8 9 10 APPENDIX B X 10 Unit and PGM Output Assignments Unit Controlled ON ON ON ON ON ON ON by Timer ON by Zone No ON No Appliance by arm HOME by arm AWAY by disarm by Memory by Delay by Keyfob ON Time OFF Time a b c by line fail 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PGM ...

Страница 27: ...ood alarm restore FT Fire Detector Clean XR Sensor Battery Restore FJ Fire detector trouble XT Sensor Battery Trouble FR Fire Restore YR System Battery Restore GA Gas alarm YT System Battery Trouble Disconnection GR Gas alarm restore YX Service Required GT Gas trouble 4 2 Event Codes Note Wireless siren reports to central station on zone 31 or 32 GSM reports to central station on zone 33 Alarms Zo...

Страница 28: ...you choose to mute them Exit Delay The exit delay begins once the user arms the system It allows him to leave via interior zones and a doorway before arming actually takes effect When the exit delay starts the buzzer beeps slowly and maintains a slow beeping rate until the last 10 seconds during which it beeps rapidly The Abbra has two types of delay zones for which different delay times may be se...

Страница 29: ...s and anti tamper protection They therefore trigger an alarm in both armed and disarmed states 24 Hour Zone Silent Upon detection this zone initiates a silent alarm meaning that the sirens do not function Instead the Abbra dials telephone numbers and reports the event to central stations and or to private telephones as programmed 24 Hour Zone Audible Upon detection this zone initiates a siren alar...

Страница 30: ...Y and HOME together for 2 sec initiates PANIC alarm Pressing AWAY for 2 sec initiates Latchkey arming DISARM AWAY AUX HOME MCT 234 B MCT 231 201 N A in North America Single button pendant units The MCT 231 Code Secure and the MCT 201 PowerCode can be enrolled to perform functions as shown Both units look alike MCT 231 201 Not UL listed C MCT 134 104 N A in North America 4 button hand held units MC...

Страница 31: ...se to an incoming call In most but not all areas the sum of the RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to the line as determined by the total RENs contact the telephone company to determine the maximum REN for the calling area If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary ...

Отзывы: