WaterMaster FET100
Electromagnetic floweter
|
Transmitter
3 Electrical Installation
OI/FET100–EN Rev. A
11
3.3 Cable Preparation (Remote Systems Only)
To prepare the cable for connection at the transmitter and sensor terminal blocks:
1.
Remove the outer cable insulation and Mylar
®
wrap.
2.
Ensure the drain wire is sleeved.
3.
Cut the cable connection wires to the lengths shown in Fig 3.5, page 12.
Fig. 3.4 Cable Gland / Conduit Entry (Remote Transmitter Shown)
AC/DC Power
Supply Terminal
Power Cable
Output Connections
External Earth
Output Connections
Sensor Cable
Output
Connections
Terminal
Sensor
Cable Terminal
Backplane
Internal Earth
(Alternative PE)
Internal Earth
(Alternative PE)
Test Points for
Output Connections