M ED I U M VO LTAG E P R O D U C T S
43
43
Instruction manual 504/05 |
VM1 Vacuum circuit-breaker 43
)
**
)
*
T
1
1
19
D
E
C
13.5
13.5
F
G
J
1) 4)
VM1
ABB
303
370
25
165
70.5
21.5
286 ±2
383
359.5
M
Q
4
50
200
320
18
76
280
310
W
0
-3
Z
Y
2)
3)
30
1) 4)
R
O
N
S
Stroke 8 -11mm
16
p
p
A
8
16
55
2)
Figure 10/5: Vacuum circuit-breaker on withdrawable part, type VM1
8)
- 12 kV, 3150
2)
/ 4000
7)
A, 25 / 31.5 kA
- 12 / 17.5 kV, 2000 / 2500 / 3150
2)
/ 4000
7)
A, 40 kA
- 17.5 kV, 3150
2)
/ 4000
7)
A, 20 / 25 / 31.5 kA
*)
Rail
**)
Front edge of bar
Table 1:
Panel type
p
N
O
Q
R
S
T
F1
G1
Powerbloc
275
694
688
698
688
118
110
144
230
UniGear-type ZS1
275
691±2
688
698
688±2
119
111±1
144±1
229±1
Table 2:
1)
Only fitted on withdrawable parts for SACE
2)
Heat sink only fitted for rated currents of 2500 A and above
3)
Remove the lifting lugs on both sides before commissioning
4)
Not fitted on withdrawable parts for Powerbloc
5)
Versions for 2000 A (with shrink sleeve)
6)
Versions for 2500 - 4000
7)
A (with heat sink, without shrinking sleeve)
7)
Breakers for 4000 A additionally with fan cooling
8)
See table page 40 and 41 (column Dimensional drawings)
Panel type
Parameters
p
A
C
D
E
J
M
W
Y
5)
Z
6)
UniGear-
type ZS1
Powerbloc
kV
A
kA
12
3150
2)
/ 4000
7)
25 / 31.5
275
850
812
836
853
844
149
109
-
x
12 / 17.5
2000 / 2500 /
3150
2)
/ 4000
7)
40
275
850
812
836
853
844
149
109
-
x
17.5
3150
2)
/ 4000
7)
20 / 25 / 31.5 275
850
812
836
853
844
149
109
-
x
BA 504-05 GB_29102012.indd 43
30.10.12 13:45
Panel type
Parameters
p
A
C
D
E
J
M
W
Y (
5
)
Z (
6
)
UniGear
type
ZS1
Powerbloc
kV
A
kA
12
31 50(
2
)/4000(
7
) 25/31 .5
275
850
81 2
836
853
844
14 9
10 9
-
x
1 2/17.5
2000/2500/
31 50(
2
)/4000(
7
)
40
275
850
81 2
836
853
844
14 9
10 9
-
x
17.5
31 50(
2
)/4000(
7
) 20/25/31 .5 275
850
81 2
836
853
844
14 9
10 9
-
x
Table 1:
Table 2:
anel type
p
N
O
Q
R
S
T
F
1
G
1
Powerbloc
275
694
688
698
688
11 8
110
14 4
23 0
UniGear
type
ZS1
275
691 ±2
688
698
688±2
11 9
111 ±1
1 44±1
229±1
Figure 10/5: Vacuum circuit breaker on withdrawable part, type VM1 (
8
)
- 12 kV, 3150 2) / 4000 7) A, 25 / 31.5 kA
- 12 / 17.5 kV, 2000 / 2500 / 3150 2) / 4000 7) A, 40 kA
- 17.5 kV, 3150 2) / 4000 7) A, 20 / 25 / 31.5 kA
(
1
) Only fitted on withdrawable parts for SACE
(
2
) Heat sink only fitted for rated currents of 2500 A and above
(
3
) Remove the lifting lugs on both sides before commissioning
(
4
) Not fitted on withdrawable parts for Powerbloc
(
5
) Versions for 2000 A (with shrink sleeve)
(
6
) Versions for 2500 - 4000 7) A (with heat sink, without shrinking sleeve)
(
7
) Breakers for 4000 A additionally with fan cooling
(
8
) See table page 40 and 41 (column Dimensional drawings)
Содержание VM1
Страница 51: ...MEDIUM VOLTAGE PRODUCTS 51 51...