5 - Installation
4. AMPHENOL H4 quick-fit connectors
Installation of Amphenol H4 connectors requires crimping to be carried
out with suitable equipment.
- Strip the cable to which you want to apply the connector (after verifying
that it complies with the connector limits).
- Apply the terminal to the conductor using the designated pliers.
Amphenol H4TC0002
- Insert the cable with the terminal into the connector, until you hear the
click indicating that the terminal is locked inside the connector.
Click
- Firmly tighten the cable gland using the relevant tool to finish the oper
-
ation.
2.6÷2.9 Nm
Amphenol
H4TW0001
7mm
4...6mm
7.6...9.3mm
2