![ABB UNO-DM-3.3-TL-PLUS Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/abb/uno-dm-3-3-tl-plus/uno-dm-3-3-tl-plus_product-manual_3698585024.webp)
- 24 -
000680AG
2 - Characteristics
UNO-DM-3.3-TL-PLUS
UNO-DM-4.0-TL-PLUS
Communication
Embedded Communication Interface
Wireless
(5)
Optional Communication Interface
RS485, Ethernet, Zigbee
(6)
Embedded Communication Protocol
ModBus TCP (SunSpec)
Optional Communication protocol
ModBus RTU (SunSpec) , Aurora Protocol
Commissioning tool
Web User Interface, Display, Aurora Manger Lite
Firmware Update Capabilities
Locally and remotely
Monitoring
Plant Portfolio Manager, Plant Viewer,
Plant Viewer for Mobile
(7)
Environmental
Ambient temperature range
-25...+60°C /-13...140°F
with derating above 50°C/122°F
Relative humidity
0...100 % condensing
Acoustic noise emission level
50 dBA @ 1 m
Maximum operating altitude without derating
2000 m / 6560 ft
Physical
Environmental protection rating
IP 65
Cooling
Natural
Dimension (H x W x D)
553mm x 418mm x 175mm / 21.8” x 16.5” x 6.9”
Weight
15 kg / 33 lb
Mounting system
Wall bracket
Safety
Isolation level
Transformerless
Marking
CE, RCM
Safety and EMC standard
IEC/EN 62109-1,
IEC/EN 62109-2,
AS/NZS 4777.2,
EN 61000-6-1,
EN 61000-6-2,
EN 61000-6-3,
EN 61000-6-4,
EN 61000-3-2,
EN 61000-3-3
IEC/EN 62109-1,
IEC/EN 62109-2,
AS/NZS 4777.2,
EN 61000-6-1,
EN 61000-6-2,
EN 61000-6-3,
EN 61000-6-4,
EN 61000-3-11,
EN 61000-3-12
Grid standard
(9)
(check your sales channel for availability)
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105,
G83/2, G59/3, RD 413, ITC-BT-40, AS/NZS 4777.2,
IEC 61727, IEC 62116
1. Refer to the document “String inverter – Product Manual appendix” available at www.abb.com/solarinverters to know the brand
and the model of the quick fit connector.
2. For UK G83/2 grid standard, maximum output current limited to 16A up to a maximum output Pacr of 3600W and maximum ap-
parent power of 3600 VA.
3. The AC voltage range may vary depending on specific country grid standard
4. The Frequency range may vary depending on specific country grid standard
5. As per IEEE 802.11 b/g/n standard
6. Availble for custom version only
7. Plant Viewer for Mobile availble remotely only, not for local commissioning
8. Pacr = 4200 W @ 45°C/113°F
9. Further grid standard will be added, please refer to ABB Solar page for further details.
Note. Features not specifically listed in the present data sheet are not included in the product