![ABB Tropos 6410 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/abb/tropos-6410/tropos-6410_installation-manual_4606046.webp)
Chapter 3
Tropos Routers Installation Guide, Models 6410 and 6420
46
Remote mount the BBU on a metal pole
1.
Use the hose clamp to secure the pole bracket to the pole, as shown in
2.
Secure the BBU mounting bracket to the pole bracket. Secure with two each 10-32 screws
(
).
3.
Connect the PoE + LAN output cable from the BBU LAN output port to the MGT port on
the router.
4.
Attach the PoE input cable to the PoE input port.
Note
When the PS079001 is remotely mounted, the data and power out cable supplied with the unit must be
replaced with an outdoor-rated Ethernet cable of sufficient length.
FIGURE 19
Remote Mounting the BBU on a Metal Pole
BBU mounting
plate
BBU
PoE Input
from
Data and power
Data in
out (to 6420)
Pole bracket
PS079001