4
3D
Reinstall the terminal block with the wires attached. Secure the
cable to the meter run pipe with the plastic tie-wraps. Do not
wrap the cable around the meter run pipe.
Supplying Power
The user has two powering options with the µFLO
G4
: Battery/Solar or
External. Steps 4 and 5 detail the Battery/Solar option. Step 6 details the
external scenario.
Step 4
Battery Pack
A battery pack provides the µFLO
G4
with its operating power. The battery
is packed and shipped separately. Before installation, inspect the power
cables where they terminate on the battery pack and the connectors for
breakage.
4A
Open the µFLO
G4
’s hinged door. Insert the battery pack into
the compartment. Ensure that the battery terminals are not
touching either the keeper lip on the shelf or any metal surface
inside of the unit.
4B
Connect the battery pack connector to the µFLO
G4
board’s
battery connection, J15. Verify that the jumper at J16 is across
pins 1 & 2 (default). Observe the LCD. Verify the LCD is on