Output power in function of output voltage
0
10
20
30
40
0
200
400
600
800
1000
5
15
25
35
45
P
[
kW
]
V [V]
CCS 2 (200A)
11.16.2
DC output specifications (Terra Mobile 54HV)
Parameter
Specification
DC output voltage range
200-920 V
Minimum DC output current
54 A
Connection standard
CCS (IEC 61851-23:2014 , IEC62196-1:
2014, IEC 62196-3: 2014)
DC output power on one EV charge cable Maximum 50 kW
DC output power on two EV charge ca-
bles
Maximum 50 kW
Simultaneous DC on 2 outlets
No. Only subsequent operation of the
outputs available.
Maximum DC output current
125 A
Charger Capacity
Voltage [V]
Current [A]
Power [kW]
150
125
19
200
125
25
300
125
38
400
125
50
500
100
50
600
83
50
700
71
50
800
63
50
Technical data
62