© Copyright 2022 ABB. All rights reserved.
OTB103.9 has pitch equal to 5.08mm.
6.2.3
Installing cage clamp terminal block 0TB103.91
Insert a screwdriver into the cage clamp terminals
➀
and secure the conductors with wire end
sleeves in the terminal contacts
➁
as shown in the figure below. Close the terminal contact by
removing the screwdriver.
When wiring, pay attention to the pinout of the power supply connection on the device!
6.2.4
Connecting the power supply to a TGP
DANGER
The entire power supply to the TGP must be interrupted. Before connecting
the power cable, it must be checked whether it has been disconnected from
the voltage source (e.g. power supply).
1.
Carry out electrostatic discharge on the housing or at the ground connection.
2.
Connect the power supply connector to the B&R device and tighten the mounting screws (max.
tightening torque 0.5 Nm).
Connecting the power supply connector to a TGP