11.5.7  Application - 1-button value transmitter, 2 objects 

At a press and release of the button the application makes it possible to send different, preset 
values via separate communication objects. 

The following communication objects are available: 

 

"Sx: switching (rising edge)“ 

 

"Sx: switching (falling edge)“ 

 

The application can differentiate between the press and the releasing of a button (rising/falling 
edge). The telegrams for the rising and falling edge can have different bit sizes. This, for 
example, allows a switching function and a floating point value to be sent. 

In each case, the application makes a separate set of parameters and communication objects 
available in function block x for both buttons. The second button of each function block can be 
occupied with an additional button function. 

 

 

Note 

The parameters for application "1-button value transmitter, 2 objects" can be 
called up via 

general parameters

 and 

extended parameters.

 

 
 
 

 

Note 

The number (S1 - Sx) of the object depends on the function block and the button 
number. 

 

 

 

Содержание tacteo KNX

Страница 1: ...2CKA001473B9488 27 03 2018 Product manual ABB tacteo ABB i bus KNX TA U3 x x xx Room outdoor sensor 3gang incl BAU ...

Страница 2: ... 17 4 2 3 Support rings 18 4 3 Functions 18 4 4 Scope of supply 19 4 5 Overview of types 19 5 Technical data 20 5 1 Technical data 20 5 2 Dimensional drawings 20 6 Connection installation mounting 21 6 1 Mounting 22 6 2 Electrical connection 25 7 Commissioning 26 7 1 Software 26 7 1 1 Preparation 26 7 1 2 Assigning a physical address 26 7 1 3 Assigning the group address es 27 7 1 4 Selecting the a...

Страница 3: ...ty status via object 49 11 3 3 Device enable Application 50 11 3 3 1 Enable with 50 11 3 3 2 After bus voltage recovery the device is 51 11 3 3 3 Use of automatic enable blockage 51 11 3 3 4 Automatic switchover time 51 11 3 3 5 Switchover time via object 52 11 3 3 6 Overwrite switchover time at download 52 11 3 3 7 Brightness of the LED during blockage 53 11 3 3 8 LED colour in a blocked state 53...

Страница 4: ...ng edge 86 11 5 7 3 Reaction on falling edge 87 11 5 7 4 Value 1 value 2 for rising edge 88 11 5 7 5 Value 1 value 2 for falling edge 89 11 5 8 Application 1 button step switch 90 11 5 8 1 Number of objects 90 11 5 8 2 Evaluation period 91 11 5 8 3 Duration of long operation 91 11 5 8 4 Sending of objects 91 11 5 8 5 Object values 92 11 5 8 6 Bit pattern of the object values 93 11 5 9 Application ...

Страница 5: ...bject type 121 11 5 15 2 Working mode of the buttons 122 11 5 15 3 Value 1 Value 2 123 11 5 16 Application 2 button value dimming sensor 124 11 5 16 1 Object type 124 11 5 16 2 Step size 125 11 5 16 3 Working mode of the buttons 125 11 5 17 Application 2 button step switch 126 11 5 17 1 Number of objects 126 11 5 17 2 Evaluation period 127 11 5 17 3 Working mode of the buttons 127 11 5 17 4 Sendin...

Страница 6: ...function 154 11 7 4 3 Number of input objects 154 11 7 4 4 Object type input x 154 11 7 4 5 Initial value input x 155 11 7 4 6 Logic input x 155 11 7 4 7 Object type output 156 11 7 4 8 Send output object 156 11 7 4 9 Value of the output object for logic true 157 11 7 4 10 Output default value true 157 11 7 4 11 Output default value true 157 11 7 4 12 Value of the output object for logic untrue 15...

Страница 7: ... 175 11 7 8 1 Channel name 175 11 7 8 2 Object type 176 11 7 8 3 Number of input objects 176 11 7 8 4 Output sends 177 11 7 8 5 Output object 177 11 7 9 Application Light scene actuator 178 11 7 9 1 Channel name 178 11 7 9 2 Number of scenes 178 11 7 9 3 Number of actuator groups 179 11 7 9 4 Duration of telegram delay 179 11 7 9 5 Overwrite scenes at download 179 11 7 9 6 Object type actuator gro...

Страница 8: ...nd damage to property and ensure both reliable operation and a long service life for the device Please keep this manual in a safe place If you pass the device on also pass on this manual along with it ABB accepts no liability for any failure to observe the instructions in this manual If you require additional information or have questions about the device please contact ABB or visit our Internet s...

Страница 9: ...on with the signal word Danger indicates an imminently threatening danger which leads to death or serious irreversible injuries Warning Serious damage to health The respective warning symbol in connection with the signal word Warning indicates a threatening danger which can lead to death or serious irreversible injuries Caution Damage to health The respective warning symbol in connection with the ...

Страница 10: ...ction of a KNX bus line The devices are available in a standard configuration or they can be individually designed via a web configurator Only components that are specific to a selected country are displayed via the web configurator Depending on the device type and configuration different functions result The standard devices are available in the e catalogue under ABB tacteo The devices are config...

Страница 11: ...ns provided The electrical installer must adhere to the valid national regulations in his her country governing the installation functional test repair and maintenance of electrical products The electrical installer must be familiar with and correctly apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth a...

Страница 12: ... its accessories Keep the device away from water and wet surroundings Danger Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and ...

Страница 13: ... high quality safety glass Yet breakage cannot be excluded Avoid force being applied to the glass plate Never reach into a broken glass with you bare hands Caution Risk of damaging the device due to external factors Moisture and contamination can damage the device Protect the device against humidity dirt and damage during transport storage and operation ...

Страница 14: ...se of the device at the appropriate collecting depot All packaging materials and devices bear the markings and test seals for proper disposal Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies The products meet the legal requirements in particular the laws governing electronic and electrical devices and the...

Страница 15: ...nd already pre mounted Additional product features LEDs as light for orientation status indication 4 1 Configurable devices The devices can be configured prior to delivery The following sectors for example can be configured according to requirement Button icons Colour of the buttons Additional text for the buttons Number of buttons up to the maximum possible for the respective size of glass plate ...

Страница 16: ...CKA001473B9488 16 4 2 Device overview 4 2 1 Overview 1 4 2 3 Fig 1 Product overview 1 Support ring 1 2 Flush mounted insert with control element 2 firmly installed unit 3 Clamps of removal protection 3 optional 4 Removal tool 4 optional ...

Страница 17: ... via the ABB tacteo configurator The buttons can be additionally fitted with text if required The functionality method of operation and installation dismantling is identical for all models 1 2 3 bell privacy service Fig 2 Models of control elements examples 1 Status indication for 3gang control elements Configurable icon and text 2 Status indication for 3gang control elements Configurable icon and...

Страница 18: ...4 3 Functions The following table provides an overview of the possible functions and applications of the device Special features Function Orientation illumination primary function Configurable covers Configurable icons and or text Function illumination Freely programmable LED colour concept Proximity function Day night switchover of the LEDs Integrated temperature sensor Comprehensive application ...

Страница 19: ...tection 3 optional Removal tool 4 optional Note Additional information about possible device versions is available in the electronic catalogue www busch jaeger catalogue com 4 5 Overview of types Models of control elements preconfigured or freely configurable Article no Product name TA U3 x x xx Room outdoor sensor 3gang incl BAU Square Vertical Horizontal Table 2 Models of control elements precon...

Страница 20: ...NX connection Bus connecting terminal screwless Line type Wire stripping 0 6 0 8 mm J Y St Y 2 x 2 x 0 8 mm 5 6 mm Bus subscribers 1 12 mA Temperature range 5 C to 45 C Storage temperature 20 C to 70 C Protection type IP 20 Table 3 Technical data 5 2 Dimensional drawings 115 86 86 33 7 30 7 86 115 Fig 5 Dimensions all dimensions are in mm ...

Страница 21: ... Disconnect 2 Secure against being re connected 3 Ensure there is no voltage 4 Connect to earth and short circuit 5 Cover or barricade adjacent live parts Use suitable personal protective clothing Use only suitable tools and measuring devices Check the type of supply network TN system IT system TT system to secure the following power supply conditions classic connection to ground protective earthi...

Страница 22: ...boxes according to DIN 49073 1 Part 1 or suitable surface mounted housings Different installation standards apply in other countries These are to be taken into account when used in connection with a different support ring and flush mounted box To install the device perform the following steps 1 Option 1 Installing the removal protection Push the removal protection into position by hand The removal...

Страница 23: ...nual 2CKA001473B9488 23 1 3 Pull the bus line out of the flush mounted box and connect the line to the bus connection terminal 1 see chapter 6 2 Electrical connection on page 25 Check that the polarity is correct Fig 8 Connection of the bus line ...

Страница 24: ...Commissioning on page 26 Programming is carried out via the programming button 1 on the rear of the device Press the programming button 1 All LEDs 2 light up red Fig 9 Programming button 5 Installing the device Snap the device into the support ring by hand The device is now mounted Fig 10 Mounting devices 1 2 ...

Страница 25: ...nnection installation mounting Product manual 2CKA001473B9488 25 6 2 Electrical connection Bus 24 V DC Carry out the electrical connection according to the circuit diagram Fig 11 Connection of bus coupler ...

Страница 26: ...KNX guidelines Detailed expert knowledge by means of KNX training sessions for a better understanding is assumed 7 1 1 Preparation 1 Connect a PC to the KNX bus line via the KNX interface e g via the commissioning interface commissioning adapter 6149 21 500 The Engineering Tool Software must be installed on the PC native application from ETS 4 0 2 Switch on the bus voltage 7 1 2 Assigning a physic...

Страница 27: ...lication program Please contact our Internet support unit www BUSCH JAEGER com The application is loaded into the device via the ETS 7 1 5 Differentiating the application program Various functions can be implemented via the ETS Detailed description of parameters see chapter 11 Description of application and parameters on page 31 only in languages DE EN ES FR IT and NL ...

Страница 28: ...ons A firmware update is carried out via the KNX bus by means of the ETS app KNX Bus Update NOTE The description of the update process can be downloaded via the electronic catalogue www busch jaeger catalogue com It is stored on the device page under category Software ...

Страница 29: ...on is carried out by touching the individual operating fields The function is specified via the assigned application function and their parameter settings Extensive functions are available for the operating fields Range of applications see chapter 11 Description of application and parameters on page 31 in languages DE EN ES FR IT NL PL and RU 9 1 Colour concept Fig 13 Models of control elements ex...

Страница 30: ...peration testing inspection maintenance and repairs according to DIN VDE 0100 520 10 2 Cleaning Caution Glass breakage The breakage of a glass plate could lead to the risk of injury Thr glass plate consists of high quality safety glass Yet breakage cannot be excluded Avoid force being applied to the glass plate Never reach into a broken glass with you bare hands Clean dirty devices with a soft dry...

Страница 31: ... element xgang 1 The application program for the control elements contains the following applications Parameter area KNX application Device settings Buzzer application Proximity application Enable application Object during operation Primary function 1 button switching Function block x 1 button switching 1 button dimming 1 button blind 1 button short long operation 1 button value transmitter 1 butt...

Страница 32: ...on button 1 button 2 Temperature Temperature sensor General functions Cyclic telegrams Priority Logic gate Gate Staircase lighting Delay Min max value transducer Light scene actuator Depending on the application selected the Engineering Tool Software ETS shows different parameters and communication objects ...

Страница 33: ...00 10 18 00 00 hh mm ss Brightness of the LED during blockage Off dark bright LED colour in a blocked state Yellow white Internal proximity status via object Deactivated activated Device settings Device enabling Enable application Enable with On off telegram After bus voltage recovery the device is Disabled enabled Use of automatic enable blockage No automatic enable automatic blockage Automatic s...

Страница 34: ... 100 Value for slats position down 0 100 Value for slats position down 0 100 Function block x 1 button short long operation Object type 1 bit 1 byte 0 100 1 byte 0 255 2 byte float 2 byte signed 2 byte unsigned 4 byte float 4 byte signed 4 byte unsigned Reaction on short operation No reaction value 1 value 2 alternating value 1 value 2 Reaction on long operation No reaction value 1 value 2 alterna...

Страница 35: ...lue 2 for falling edge Setting dependent on object type Function block x 1 button step switch Number of objects 1 5 Evaluation period 02 000 05 000 ss fff Duration of long operation 00 300 02 500 ss fff Sending of objects At operation at value change Object values Normal inverse Bit pattern of the object values x off n 1 off n Function block x 1 button multiple operation Number of objects or opera...

Страница 36: ...hing 1st button on 2nd button off 1st button off 2nd button on alternating on off Working mode of the buttons for dimming 1st button brighter 2nd button darker 1st button darker 2nd button brighter Dimming stop telegram Dimming stop is not sent dimming stop is sent Cyclic sending of the dimming telegrams Deactivated activated Duration of telegram repetition 00 100 05 000 ss fff Function block x 2 ...

Страница 37: ... type for status object 1 bit 1 byte 0 100 Brightness of the colours Dark bright Colour for Off Off yellow white Colour for On Off yellow white Colour for Zone 1 corresponds to 0 Off yellow white Colour for Zone 2 starting at 1 Off yellow white Threshold between Zone 2 and 3 1 98 Colour for Zone 3 Off yellow white Threshold between Zone 3 and 4 2 99 Colour for Zone 4 up to 99 Off yellow white Colo...

Страница 38: ...R XOR XNOR NAND NOR Number of input objects 1 10 Object type input x 1 bit 1 byte Initial value input x Initialised with 0 Initialised with 1 Logic input x Normal inverse Object type output 1 bit 1 byte Send output object At each incoming telegram at each change of output object Value of the output object for logic true Output is set on 1 defined via output default value true Output default value ...

Страница 39: ...ed Switch off pre warning Deactivated activated Time for switch off pre warning s 1 5400 Value for switch off prewarning 1 100 Overwrite at switch off delay and switch off prewarning time during download Deactivated activated General functions channel x Delay Channel name Name Object type 1 bit switching 1 bit moving 1 bit stop adjusting 1 byte 0 100 1 byte 0 255 2 byte float 2 byte signed 2 byte ...

Страница 40: ...sumes the smallest input value assumes the input average General functions channel x Light scene actuator Channel name Name Number of scenes 1 8 Number of actuator groups 1 8 Duration of telegram delay 00 100 10 000 ss fff Overwrite scenes at download Deactivated activated Object type actuator group x Light scene number 1 bit switching 1 bit blind 1 byte 0 100 temperature Scene number 1 64 Scene c...

Страница 41: ...cts are available BUZ object activation of acoustic feedback signal BUZ triggering an alarm BUZ time for automatic deactivation of the alarm The communication objects are enabled via the associated parameters Note The following parameters can only be adjusted when the function Acoustic feedback signal is set on Buzzer application The parameters for application Acoustic feedback signal can be calle...

Страница 42: ...d with this parameter The further differentiation is carried out via the parameter that is available after enabling 11 3 1 3 Activation of the acoustic feedback signal with Options On telegram Off telegram ON telegram Activation via On telegram Off telegram Activation via Off telegram The parameter is used to specify whether the acoustic feedback signal is activated via the input object at the rec...

Страница 43: ...ated If deactivated has been selected the Acoustic feedback signal via object does not start after bus voltage recovery Note The parameter can only be set when parameter Acoustic feedback signal via object is activated 11 3 1 5 Acoustic alarm via object Options Deactivated Activated Deactivated The communication object is not enabled Activated The communication object is enabled A 1 byte communica...

Страница 44: ...edback signal is activated via the input object at the receipt of an On or an Off telegram Note The parameter can only be set when parameter Acoustic feedback signal via object or parameter Acoustic alarm via object is activated 11 3 1 7 Alarm via the button Options Deactivated Activated Deactivated The pending alarm can not be deactivated with a press of the button Activated The pending alarm can...

Страница 45: ...rameter Time for automatic ending of the alarm The further differentiation is carried out via the parameter that is available after enabling Note The parameter can only be set when parameter Acoustic alarm via object is activated 11 3 1 9 Time for automatic ending of the alarm Options Setting option from 00 00 10 to 18 00 00 hh mm ss The set value defines the time for the automatic ending of the p...

Страница 46: ...ers Acoustic alarm via object and Ending the alarm automatically are activated 11 3 1 11 Time for automatic ending at overwrite download Options Deactivated Activated Deactivated Time for automatic ending is not overwritten during a download of the application Activated Time for automatic ending is overwritten during a download of the application The parameter can be used to specify whether the da...

Страница 47: ...ailable NARX proximity NARX internal proximity status The communication objects are enabled via the associated parameters Note The following parameters can only be adjusted when the function Proximity is set on Proximity application The parameters for application Proximity can be called up via general parameters 11 3 2 1 External proximity via object Options Deactivated Activated Deactivated The c...

Страница 48: ...utomatic switchover time In this way for example the display stays switched on for a while longer although the user has just moved away from the device Note The parameter can only be set when parameter External proximity via object is deactivated 11 3 2 3 Brightness of the LED during blockage Options Off Dark Bright Off The LED does not light up at blockage Dark The LED lights up dark at blockage ...

Страница 49: ...LED lights up in when the device is blocked Note The parameter is only adjustable if the Brightness of LED during blockage parameter is set on dark or bright 11 3 2 5 Internal proximity status via object Options Deactivated Activated Deactivated The communication object is not enabled Activated The communication object is enabled A 1 bit communication object NARX internal proximity status can be e...

Страница 50: ...legram The following communication objects are available EF enable EF automatic switchover time The communication objects are enabled via the associated parameters Note The following parameters can only be adjusted when the function Device enable is set on Enable application The parameters for application Device enable can be called up via general parameters 11 3 3 1 Enable with Options On telegra...

Страница 51: ...enable or blockage of the device Automatic enable Function Automatic enable is active Automatic blockage Function Automatic blockage ia active The parameter can be used to automatically enable or automatically block the device 11 3 3 4 Automatic switchover time Options Setting option from 00 00 10 to 18 00 00 hh mm ss The switching on or switchover always occurs immediately the user has approached...

Страница 52: ...f automatic enable blockage parameter is set on Automatic enable or Automatic blockage 11 3 3 6 Overwrite switchover time at download Options Deactivated Activated Deactivated The switchover time is not overwritten during a download of the application Activated The switchover time is overwritten during a download of the application The parameter can be used to specify whether the data changed via ...

Страница 53: ...t at blockage The parameter is used to specify whether or in which brightness the LED lights up when the device is blocked 11 3 3 8 LED colour in a blocked state Options Yellow Orange Red Violet Blue Green White Yellow white The LED lights up in the specified colour during blockage The parameter is used to specify the colour the LED lights up in when the device is blocked Note The parameter is onl...

Страница 54: ...nication object is available HB output Note The following parameters can only be adjusted when the function Function during operation is set on Object during operation The parameters for application Function during operation can be called up via general parameters 11 3 4 1 Cycle time Options Setting option from 00 00 55 to 01 30 00 hh mm ss The telegrams of the object during operation are sent cyc...

Страница 55: ...is the first function of the device that is carried out when the user presses button 1 or 2 The primary function should be a function that the user would use when entering the room for example e g switching the ceiling light When the application is active a switching telegram is sent when the button is pressed or released The following communication object is available PF switching Note The follow...

Страница 56: ...0 255 The value is sent as 1 byte value without a sign Any value 0 255 Light scene number 1 64 Value is sent as scene number or scene control 1 64 RTC operating mode switchover 1 byte Value is sent as 1 byte value for the RTC operating mode switchover e g auto comfort ECO when the room temperature controller has been linked The 1 button value switching application makes communication object PF swi...

Страница 57: ...at the press of the button Application 1 button value switching can differentiate between the press and the releasing of the button A press is defined as Rising edge and the releasing as Falling edge The parameter is used to specify whether a telegram with value 1 or value 2 is sent on the bus at a rising edge via communication object PF switching A further option can be specified as to whether th...

Страница 58: ...ue 1 or value 2 is sent on the bus at a falling edge via communication object PF switching A further option can be specified as to whether the telegrams are sent alternately This means that after value 1 has been sent value 2 is sent at a renewed release of the button After it is released again value 1 is again sent out Note Parameter Value 1 and Value 2 is used to specify the values that are to b...

Страница 59: ...n from 0 to 100 Options for selection 1 byte 0 255 Options Setting option from 0 to 255 Options for selection Light scene number 1 64 Options Setting option from 1 to 64 Options for selection RTC operating mode switchover 1 byte Options Auto Comfort Standby ECO Frost heat protection The parameter is used to set value 1 that is sent at a press of the button Note Parameter can only be set if the Rea...

Страница 60: ...om 0 to 100 Options for selection 1 byte 0 255 Options Setting option from 0 to 255 Options for selection Light scene number 1 64 Options Setting option from 1 to 64 Options for selection RTC operating mode switchover 1 byte Options Auto Comfort Standby ECO Frost heat protection The parameter is used to set value 2 that is sent at a press of the button Note Parameter can only be set if the Reactio...

Страница 61: ...applications Options 1 button switching 1 button dimming 1 button blind 1 button short long operation 1 button value transmitter 1 button value transmitter 2 objects 1 button step switch 1 button multiple operation 1 button light scene extension unit with memory function 1 button operating mode Adjust RTC 2 button switching 2 button dimming 2 button blind 2 button value transmitter 2 button value ...

Страница 62: ...sent for each single and multiple press of the button Additional information See Application 1 button multiple operation on page 94 1 button light scene extension unit with memory function The application can be used to call up and save one of 64 possible light scenes with a press of the button Additional information See Application 1 button light scene extension unit with memory function on page ...

Страница 63: ...88 63 2 button step switch Up to five switching levels can be activated for a button pair via the application One button is used to switch the steps up and the other button to switch them down Additional information See Application 2 button step switch on page 126 Inactive No applications are enabled ...

Страница 64: ...ber S1 Sx of the object depends on the function block and the button number 11 5 2 1 Reaction on rising edge Options Deactivated Off On Alternating on off Deactivated No telegram is sent at the press of the button Off The Off telegram is sent at the press of the button at rising edge On The On telegram is sent at the press of the button at rising edge Alternating on off On and Off are sent alterna...

Страница 65: ... and Off are sent alternately when the button is released Application 1 button value switching can differentiate between the press and the releasing of the button A press is defined as Rising edge and the releasing as Falling edge The parameter is used to specify whether an On or Off telegram is sent on the bus at a falling edge via the 1 bit communication object Sx switching A further option can ...

Страница 66: ...rs for application 1 button dimming can be called up via general parameters Note The number S1 Sx of the object depends on the function block and the button number 11 5 3 1 Duration of long operation Options Setting option from 00 300 to 03 000 ss fff The application can differentiate between a short and a long press of the button With a short press of the button the next level forward is switched...

Страница 67: ...fter On is sent Off is sent at a renewed press of the button After it is pressed again On is sent 11 5 3 3 Working mode of the buttons for dimming Options Darker Brighter Alternating brighter darker Darker The Dim darker command is sent at a long press of the button Brighter The Dim brighter command is sent at a long press of the button Alternating brighter darker Dim darker and Dim brighter are s...

Страница 68: ...and A short press of the button triggers a command to adjust the slats Roller blinds Movement and stop commands are sent to linked roller blind actuators with long and short button operations A long press of the button triggers a move command A short press of the button triggers a stop command Blinds and roller blinds The sensor stores the last command carried out with the button that is occupied ...

Страница 69: ... the press of the button The command is also sent if the button is pressed long and a Adjust slats command is sent due to the long operation This causes a short jerking of the blind since the first slats adjustment command is always interpreted by a blind actuator as a stop command 11 5 4 2 Cycle time of the telegram repetition Options Setting option from 00 100 to 05 000 ss fff Telegrams are sent...

Страница 70: ...ith 1 byte position objects of the blind actuators Also desired positions of the blind can be preset under Extended parameters Example Button 1 always moves the blind down to 50 with the slats closed at 50 Button 1 always moves the blind down to 80 with the slats closed at 100 Note The parameter can only be set if the Blind roller blind function switchover parameter is set on Blind 11 5 4 4 Functi...

Страница 71: ...The parameter can only be set if the Blind roller blind switchover function parameter is set on Blind and the Object type parameter is set on 1 byte 0 100 11 5 4 6 Value for position up Options Setting option from 0 to 100 The parameter is used to set the position to which a linked blind is to be raised The associated 1 byte communication object Sx position must hereby be connected with a 1 byte p...

Страница 72: ...e parameter can only be set if the Blind roller blind switchover function parameter is set on Blind and the Object type parameter is set on 1 byte 0 100 11 5 4 8 Value for slats position down Options Setting option from 0 to 100 The parameter is used to set the position to which the slats of the linked blind are to close The associated 1 byte Sx slat position communication object must hereby be co...

Страница 73: ...The two objects can take on different sizes 1 bit 4 byte depending on the object type selected In each case the application makes a separate set of parameters and communication objects available in function block x for both buttons The second button of each function block can be occupied with an additional button function Note The parameters for application 1 button short long operation can be cal...

Страница 74: ...oating point value 671088 6 670760 9 e g temperature or moisture value 2 byte signed The value is sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float The value is sent as 4 byte floating point value physical values e g luminosity electric power pr...

Страница 75: ...ort press of the button Alternating value 1 value 2 Value 1 and value 2 are sent alternately at a short press of the button The parameter is used to specify whether value 1 or value 2 is sent on the bus at a short press of the button A further option can be specified as to whether the telegrams are sent alternately This means that after value 1 has been sent value 2 is sent at a renewed press of t...

Страница 76: ...the telegrams are sent alternately This means that after value 1 has been sent value 2 is sent at a renewed press of the button After it is pressed again value 1 is again sent out Note Parameter Value x for long operation is used to specify the values that are to be sent 11 5 5 4 Duration of long operation Options Setting option from 00 300 to 03 000 ss fff The application can differentiate betwee...

Страница 77: ... option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 2147483647 Options for selection 4 byte unsigned Options Setting option from 0 to 4294967295 The parameter is used to set value 1 or va...

Страница 78: ...ng option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 2147483647 Options for selection 4 byte unsigned Options Setting option from 0 to 4294967295 The parameter is used to set value 1 or ...

Страница 79: ...can differentiate between the press and the releasing of a button rising falling edge All telegrams have the same bit size In each case the application makes a separate set of parameters and communication objects available in function block x for both buttons The second button of each function block can be occupied with an additional button function Note The parameters for application 1 button val...

Страница 80: ...he value is sent as floating point value 671088 6 670760 9 e g temperature or moisture value 2 byte signed The value is sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float The value is sent as 4 byte floating point value physical values e g lumino...

Страница 81: ...lication 1 button value transmitter can differentiate between the press and the releasing of the button A press is defined as Rising edge and the releasing as Falling edge Only one communication object is available for both edges The parameter is used to specify whether a telegram with value 1 or value 2 is sent on the bus at a rising edge via communication object Sx switching A further option can...

Страница 82: ...pplication 1 button value transmitter can differentiate between the press and the releasing of a button A press is defined as Rising edge and the releasing as Falling edge Only one communication object is available for both edges The parameter is used to specify whether a telegram with value 1 or value 2 is sent on the bus at a falling edge via communication object Sx switching A further option ca...

Страница 83: ...255 Options for selection 2 byte float Options Setting option from 671088 64 to 670760 96 Options for selection 2 byte signed Options Setting option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 21474836...

Страница 84: ...the releasing of a button rising falling edge The telegrams for the rising and falling edge can have different bit sizes This for example allows a switching function and a floating point value to be sent In each case the application makes a separate set of parameters and communication objects available in function block x for both buttons The second button of each function block can be occupied wi...

Страница 85: ...ating point value 671088 6 670760 9 e g temperature or moisture value 2 byte signed The value is sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float The value is sent as 4 byte floating point value physical values e g luminosity electric power pre...

Страница 86: ...ferentiate between the press and the releasing of a button A press is defined as Rising edge and the releasing as Falling edge The application makes two separate communication objects available for the rising and falling edge of a button The parameter is used to specify whether a telegram with value 1 or value 2 is sent on the bus at a rising edge via communication object Sx switching rising edge ...

Страница 87: ...ferentiate between the press and the releasing of a button A press is defined as Rising edge and the releasing as Falling edge The application makes two separate communication objects available for the rising and falling edge of a button The parameter is used to specify whether a telegram with value 1 or value 2 is sent on the bus at a falling edge via communication object Sx switching falling edg...

Страница 88: ...Setting option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 2147483647 Options for selection 4 byte unsigned Options Setting option from 0 to 4294967295 The parameter is used to set value ...

Страница 89: ...tting option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 2147483647 Options for selection 4 byte unsigned Options Setting option from 0 to 4294967295 The parameter is used to set value 1 ...

Страница 90: ...n 1st button 1st press 1st step switches lamp 1 on 1st button 2nd press 2nd step switches lamp 1 off and lamp 2 on 1st button 3rd press 3rd step switches lamp 2 off and lamp 3 on 2nd button 1st press 2nd step switches lamp 3 off and lamp 2 on 2nd button 2nd press 1st step switches lamp 2 off and lamp 1 on In each case the application makes a separate set of parameters and communication objects ava...

Страница 91: ...nd a long press of the button With a short press of the button the next level forward is switched to With a long press of the button the first level is activated Thus with a long press of the button a jump back from every level to the first level is possible without having to run through the remaining levels The parameter is used to specify the time from which a long press of the button is recogni...

Страница 92: ...mal Values of the individual switching levels are not sent inverted Inverse Values of the individual switching levels are sent inverted The parameter is used to specify whether values of the 1 bit communication objects Sx switching step x are sent normal or inverted Example five objects x of n The object value 10000 is sent inverted as object value 01111 ...

Страница 93: ...or the bit pattern x off n 1 object 2 objects 3 objects 4 objects 5 objects Level 0 0 00 000 0000 00000 Level 1 1 10 100 1000 10000 Level 2 11 110 1100 11000 Level 3 111 1110 11100 Level 4 1111 11110 Level 5 11111 Object values for the bit pattern 1 off n 1 object 2 objects 3 objects 4 objects 5 objects Level 0 0 00 000 0000 00000 Level 1 1 10 100 1000 10000 Level 2 01 010 0100 01000 Level 3 001 0...

Страница 94: ...r both buttons The second button of each function block can be occupied with an additional button function Note The parameters for application 1 button multiple actuation can be called up via general parameters and extended parameters Note The number S1 Sx of the object depends on the function block and the button number 11 5 9 1 Number of objects or operations Options Setting option from 1 to 5 T...

Страница 95: ...egrams are sent parallel via the activated communication objects For the device to recognize a multiple operation the button operation must be carried out within a defined time period evaluation period The time is started after the first actuation and continues for the set evaluation period A typical value for the evaluation period is 3 seconds Example five objects The five objects Sx switching x ...

Страница 96: ...e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float The value is sent as 4 byte floating point value physical values e g luminosity electric power pressure 4 byte signed The value is sent as 4 byte value with a sign 2147483648 2147483647 e g counting impulse time difference 4 byte unsigned T...

Страница 97: ...sent Alternating on off On and Off are sent alternately at the press of the button The parameter is used to specify whether an On or an Off telegram is sent via 1 bit communication object Sx switching x actuation s when the button is pressed A further option can be specified as to whether the switching telegrams are sent alternately This means that after On is sent Off is sent at a renewed press o...

Страница 98: ...tion from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 2147483647 Options for selection 4 byte unsigned Options Setting option from 0 to 4294967295 The parameter is used to set the value that i...

Страница 99: ...tons The second button of each function block can be occupied with an additional button function Note The parameters for application 1 button light scene extension unit with memory function can be called up via general parameters Note The number S1 Sx of the object depends on the function block and the button number 11 5 10 1 Duration of long operation Options Setting option from 00 300 to 10 000 ...

Страница 100: ... sent to all connected actuators that answer with their current object values The answers are saved by the light scene module and are sent out at every new receipt of the light scene number 11 5 10 3 Number of light scene Options Setting option from 1 to 64 The parameter is used to specify the light scene number which is sent via the 1 byte communication object Sx light scene number at the press o...

Страница 101: ...g room temperature controllers that have a 1 byte object for the switchover of the KNX operating modes The following operating modes and object values can be set via the application Auto value 0 Comfort value 1 Standby value 2 Eco value 3 Frost protection heat protection value 4 The function can be temporarily blocked via 1 bit object Sx enable In each case the application makes a separate set of ...

Страница 102: ...with 1 bit communication objects for operating mode switchover 1 byte Object type for the control of RTC with 1 byte communication objects for KNX operating mode switchover The parameter us used to fix the size of object Sx operating mode For setting 1 byte the following values are sent dependent on the setting of the Operating mode parameter 0 auto 1 comfort 2 standby 3 night 4 frost heat protect...

Страница 103: ...bject and a linked RTC switches over into comfort mode Standby Switching signal On is sent via the 1 bit object and a linked RTC switches over into standby mode ECO Switching signal On is sent via the 1 bit object and a linked RTC switches over into ECO mode Frost heat protection Switching signal On is sent via the 1 bit object and a linked RTC switches over into frost heat protection mode The par...

Страница 104: ...sed to switch over to the standard operating mode object Comfort Value 1 is sent via the 1 byte object and a linked RTC switches over into comfort mode Standby Value 2 is sent via the 1 byte object and a linked RTC switches over into standby mode ECO Value 3 is sent via the 1 byte object and a linked RTC switches over into ECO mode Frost heat protection Value 4 is sent via the 1 byte object and a ...

Страница 105: ...object Sx operating mode Note If the Enable object parameter is activated the following parameters can be set Object value enable object Enable object after return of voltage 11 5 11 4 Object value enable object Options Normal Inverse Normal If an On telegram value 1 is received via communication object Sx enable local switchover of operating modes is possible An Off telegram value 0 deactivates t...

Страница 106: ...tivated No telegram is sent via object Sx comfort operating mode at the press of the operating mode switchover button Activated A telegram is sent via object Sx comfort operating mode at the press of the operating mode switchover button The telegram that is sent always has the inverted value of the value sent last This means that 0 or 1 is sent toggle mode alternately via object Sx comfort operati...

Страница 107: ...te The parameter can only be set if the Object type for output parameter is set on 1 bit and the Operating mode parameter is set on Standby or ECO 11 5 11 8 Send frost object Options Deactivated Activated Deactivated No telegram is sent via object Sx frost operating mode at the press of the operating mode switchover button Activated A telegram is sent via object Sx frost operating mode at the pres...

Страница 108: ...on 2nd button off When the first button is pressed the On command is sent and the Off command when the second button is pressed 1st Button off 2nd button on When the first button is pressed the Off command is sent and the On command when the second button is pressed Alternating on off On and Off are sent alternately at the press of the first or second button The parameter is used to specify for ex...

Страница 109: ...whether the light is dimmed with a short or long press of the button The application makes a joint set of parameters and communication objects available in function block x for both buttons Note The parameters for application 2 button dimming can be called up via general parameters and extended parameters Note The number S1 Sx of the object depends on the function block and the button number 11 5 ...

Страница 110: ...t Stop dimming two 3 bit telegrams for dimming are sent At a press of the button the first telegram with the command Dim 100 brighter or Dim 100 darker is sent to the linked dimming actuator When the button is released the second telegram with the command Stop dimming is sent Hence a connected dimming actuator can be halted at any time during the dimming phase For step wise dimming a defined value...

Страница 111: ...alue of 70 With a press of the button the command Dim brighter by 12 5 is sent After receiving the dimming command the dimming actuator increases the brightness value to 82 5 Note If step wise dimming is used to evenly dim multiple dimming actuators in different lines a low step size should be selected e g 3 13 At the same time the cyclical sending of the dimming telegrams should be activated This...

Страница 112: ...ress of the button Short operation switching long operation dimming The switching telegram is sent at a short press of the button The dimming telegram is sent at a long press of the button The application can differentiate between a short and a long press of the button The parameter is used to specify whether a switching telegram or a dimming telegram is sent on the bus at a short or long press of...

Страница 113: ...he two buttons After one of the two buttons is pressed again On is sent again This also applies for values that are received via the associated 1 bit communication object Sx switching This means that when an Off command is received after an On command was sent via object Sx switching an On command is sent after the button is pressed again It must be ensured here that the S flag writing of the comm...

Страница 114: ...ise dimming and parameter Dimming function is set on Short operation switching long operation dimming 11 5 13 8 Cyclic sending of the dimming telegrams Options Deactivated Activated Deactivated No dimming telegrams are sent cyclic as long as the button is pressed Activated Telegrams are sent cyclic as long as the button is pressed The parameter is used to specify whether dimming telegrams are sent...

Страница 115: ...a communication object Sx relative dimming as long as the button is pressed The parameter is used to set time intervals between the telegrams The default setting is 1 second Note The parameter is available only via the following settings Parameter Manner of dimming is set on Step wise dimming and Parameter Dimming function is set on Short operation switching long operation dimming and Parameter Cy...

Страница 116: ...mmands are sent to linked blind actuators with long and short button operations A long press of the button triggers a move command A short press of the button triggers a command to adjust the slats The sensor stores the last command carried out with the button that is occupied with the application This means for example if a blind was lowered and halted at half height via a short press of the butt...

Страница 117: ...nt if the button is pressed long and a Adjust position slats command is sent due to the long operation This causes a short jerking of the blind since the first slats adjustment command is always interpreted by a blind actuator as a stop command 11 5 14 2 Object type Options 1 bit 1 byte 0 100 1 bit The value is sent as 1 bit switching commands up down or adjustment 1 byte 0 100 The value is sent a...

Страница 118: ... position to which a linked blind is to be lowered The associated 1 byte communication object Sx position must hereby be connected with a 1 byte position object of the blind actuator Percentage values can be set in steps of 1 Meaning of the percentage values 0 blind completely raised 100 blind completely lowered Note The parameter is only adjustable if the object type parameter is set to 1 byte 0 ...

Страница 119: ...tage values 0 slats completely open 100 slats completely closed Note The parameter is only adjustable if the object type parameter is set to 1 byte 0 100 11 5 14 7 Value for slats position down Options Setting option from 0 to 100 The parameter is used to set the position to which the slats of the linked blind are to close The associated 1 byte Sx slat position communication object must hereby be ...

Страница 120: ...ith the press of the first button A telegram with value 2 is sent with the second button Both values have the same bit size and are sent on the bus via the Sx switching value communication object The bit size is specified via the Object type parameter The application makes a joint set of parameters and communication objects available in function block x for both buttons Note The parameters for app...

Страница 121: ... sent as floating point value 671088 6 670760 9 e g temperature or moisture value 2 byte signed The value is sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float The value is sent as 4 byte floating point value physical values e g luminosity electr...

Страница 122: ...he press of the first or second button The parameter is used to specify the value that is sent on the bus via communication object Sx switching at a press of the first or second button A further option can be specified as to whether the values are sent alternately independent from the button pressed This means that after value 1 is sent value 2 is sent at a renewed press of one the two buttons Aft...

Страница 123: ...r selection 2 byte float Options Setting option from 671088 64 to 670760 96 Options for selection 2 byte signed Options Setting option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 21474836...

Страница 124: ...of parameters and communication objects available in function block x for both buttons Note The parameters for application 2 button value dimming sensor can be called up via general parameters Note The number S1 Sx of the object depends on the function block and the button number 11 5 16 1 Object type Options 1 byte 0 100 1 byte 0 255 1 byte 0 100 The value is sent as 1 byte value without a sign p...

Страница 125: ...t type 1 byte 0 255 The current value is raised or lowered by the set absolute value with a press of a button Example The current value of the dimming actuator is 100 If the parameter is set on step size 20 the current value is raised from 100 to 120 or lowered to 80 with a press of the button 11 5 16 3 Working mode of the buttons Options 1st button brighter 2nd button darker 1st button darker 2nd...

Страница 126: ...Example 1st button up 2nd button down 1st button 1st press 1st step switches lamp 1 on 1st button 2nd press 2nd step switches lamp 1 off and lamp 2 on 1st button 3rd press 3rd step switches lamp 2 off and lamp 3 on 2nd button 1st press 2nd step switches lamp 3 off and lamp 2 on 2nd button 2nd press 1st step switches lamp 2 off and lamp 1 on The application makes a joint set of parameters and commu...

Страница 127: ...on up 2nd button down 1st button down 2nd button up When the first button is pressed the Step down command is sent and the Step up command when the second button is pressed 1st button up 2nd button down When the first button is pressed the Step up command is sent and the Step down command when the second button is pressed The parameter is used to specify whether the first or second button triggers...

Страница 128: ... of n The object value 10000 is sent inverted as object value 01111 11 5 17 6 Bit pattern of the object values Options x of n 1 of n The levels can be switched in two different bit patterns Object values for the bit pattern x off n 1 object 2 objects 3 objects 4 objects 5 objects Level 0 0 00 000 0000 00000 Level 1 1 10 100 1000 10000 Level 2 11 110 1100 11000 Level 3 111 1110 11100 Level 4 1111 1...

Страница 129: ...function can be called up in each function block via general parameters and extended parameters Note The number S1 Sx of the object depends on the function block and the button number 11 5 18 1 Operating mode Options Status illumination Function illumination Status illumination The LED displays the device status with different colours Function illumination The LED displays the device functions wit...

Страница 130: ...is stored in the Colour for On parameter If an OFF telegram is received via the object the LED lights up in the colour that is stored in the Colour for Off parameter The LED can also be switched off For selection 1 byte 0 100 the 1 byte object Sx status LED is available If a value telegram is received via the object the LED lights up in the colour that is set in the Colour for zone parameter The L...

Страница 131: ...stable if the Day night mode parameter is set on deactivated 11 5 18 4 Colour for Off Options Off Yellow Red orange Red Violet Blue Green White Off The button LEDs are switched off Yellow white The button LEDs light up in the fixed colour at switching signal Off The parameter is used to specify the colour the button LED lights up in when the device receives an Off telegram via the 1 bit communicat...

Страница 132: ...ow white The LED lights up in the fixed colour at switching signal On The parameter is used to specify the colour the button LED lights up in when the device receives an On telegram via the 1 bit communication object Lx status LED The default setting is red Note The parameter can only be set if the Operating mode parameter and is set on Status illumination and the Object type for status object par...

Страница 133: ... Yellow white The LED lights up in the fixed colour at value telegrams for zone 1 The parameter is used to specify the colour the LED lights up in when a telegram with value 0 is received via the 1 byte communication object Lx status LED The default setting is green Note The parameter can only be set if the Operating mode parameter and is set on Status illumination and the Object type for status o...

Страница 134: ...t setting is yellow The threshold value S1 is set via the parameter Threshold between Zone 2 and 3 Note The parameter can only be set if the Operating mode parameter and is set on Status illumination and the Object type for status object parameter is set on 1 byte 0 100 11 5 18 8 Threshold between Zone 2 and 3 Options Setting option from 1 to 98 The parameter is used to set the threshold value S1 ...

Страница 135: ...lds S1 and S2 are specified via the parameters Threshold between zone 2 and 3 and Threshold between zone 3 and 4 Note The parameter can only be set if the Operating mode parameter and is set on Status illumination and the Object type for status object parameter is set on 1 byte 0 100 11 5 18 10 Threshold between Zone 3 and 4 Options Setting option from 2 to 99 The parameter is used to set the thre...

Страница 136: ...e 4 The parameter is used to specify the colour the LED lights up in when a telegram with a value is received via the 1 byte communication object Lx status LED which meets the following conditions Value is S2 and Value is 99 The default setting is red orange The threshold value S2 is set via the parameter Threshold between Zone 3 and 4 Note The parameter can only be set if the Operating mode param...

Страница 137: ...f Yellow white The LED lights up in the fixed colour at value telegrams for zone 5 The parameter is used to specify the colour the LED lights up in when a telegram with value 100 is received via the 1 byte communication object Lx status LED The default setting is red Note The parameter can only be set if the Operating mode parameter and is set on Status illumination and the Object type for status ...

Страница 138: ...tched off Yellow white The LED lights up in the selected colour The parameter is used to specify the colour the associated function icon of the device lights up in The LED additionally serves for orientation this means that the buttons can be recognized in the dark Alternatively the LED can also be switched off such as when the device is in a sleeping area Note The parameter is only adjustable if ...

Страница 139: ... switches a lamp group The LED of the button is set on Status illumination and a colour If the Lx day night mode object is additionally connected with the status response object of the switching actuator via a group address or action and the light is switched on the LED lights up bright When the light is switched off the LED lights up dark Note The parameter is available via the following settings...

Страница 140: ... illumination If object Lx Day night mode is enabled the LED flashes either bright or dark Note The parameter is available via the following settings The parameter is set on Status illumination and Parameter Object type for status object is set on 1 bit and Parameter Colour for Off is set on a colour and not on Off and Parameter Colour for On is set on a colour and not on Off The parameter is avai...

Страница 141: ... The alarm function can for example display a wind alarm or an open door when the user wants to lower a blind or a roller blind Note The parameter is available via the following settings The parameter is set on Status illumination and Parameter Object type for status object is set on 1 bit and Parameter Colour for Off is set on a colour and not on Off and Parameter Colour for On is set on a colour...

Страница 142: ...ature sensor is the slave device and the RTC the master device Slave devices must be linked with the master device via the appropriately labelled communication objects The slave device operates the RTC functions of the master device Note The following parameters can only be adjusted when the function Temperature is set on Temperature sensor The parameters for Temperature can be called up via gener...

Страница 143: ...lue from which the actual temperature is sent during the cycle time setting value x 0 1 Kelvin T Note The cycle time for sending the actual temperature starts anew after the actual temperature has been sent due to an exceeding of the set temperature difference Note The parameter is only adjustable if the Send measured value parameter is set on Cyclic and at value change 11 6 1 4 Offset of the temp...

Страница 144: ... The offset adjusted via parameter Offset of the temperature sensor x 0 1 C is not overwritten Yes The set offset is overwritten with communication object TS actual temperature for temperature compensation With selection Yes an actual temperature value can be sent to the device without opening the ETS application which overwrites the parameterised offset ...

Страница 145: ...ceived via communication object GFx switch input are transferred to object GFx output depending on the state of the GFx input priority object Additional information See Application Priority on page 152 Logic gate The application is used to specify the logic gate the communication objects GFx input 1 GFx input 2 and GFx output are to be linked with Additional information See Application Logic gate ...

Страница 146: ...tion See Application Min max value transducer on page 175 Light scene actuator With the application it is possible to call up scenes that are stored in the device via the receipt of a scene number on the 1 byte communication object GFx scene call up Additional information See Application Light scene actuator on page 178 Note The following parameters can only be adjusted when the corresponding appl...

Страница 147: ...egram on object GFx input a telegram with the same content is sent cyclic via the application on the bus via object GFx output The object types for GFx input and GFx output can be collectively parameterised for the different applications The times for cyclic sending via GFx output object are adjustable An additional GFx enable object provides the option of temporarily blocking the function Note Th...

Страница 148: ...lue is sent as 1 byte value without a sign Any value 0 255 2 byte float The value is sent as floating point value 671088 6 670760 9 e g temperature or moisture value 2 byte signed The value is sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float Th...

Страница 149: ...ication object GFx enable can be enabled with this parameter Note If the Enable object parameter is activated the following parameters can be set Object value enable object Enable object after return of voltage 11 7 2 5 Object value enable object Options Normal Inverse Normal If an Off telegram is received via the object GFx enable the function Cyclic telegram is blocked An On telegram deactivates...

Страница 150: ...of bus voltage Note This parameter can only be set if the Enable object parameter is set on activated 11 7 2 7 Cyclic sending Options Always activated Activated at a specified value Activated except at a specified value Always activated Telegrams that are received on object GFx input are transferred directly to object GFx output and there sent cyclic Activated at a specified value This value is se...

Страница 151: ...64 to 670760 96 Options for selection 2 byte signed Options Setting option from 32768 to 32767 Options for selection 2 byte unsigned Options Setting option from 0 to 65535 Options for selection 2 byte temperature Options Setting option from 273 to 500 Options for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 21...

Страница 152: ...t has no meaning The GFx output object is switched on positively driven and has the value 1 GFx priority input has the value 2 The value that is present on GFx switch input has no meaning The GFx output object is switched off positively driven and has the value 0 GFx priority input has the value 1 or 0 The GFx output object is not positively driven The GFx switch input is linked to the status bit ...

Страница 153: ...At the receipt of new telegrams at the inputs they are switched according to the selected function The inputs can also be individually inverted The result determined from the inputs is sent via the output object The default value that is to be sent at a positive result can be adjusted Note The parameters for application Logic gate can be called via general parameters parameter input x and output p...

Страница 154: ... objects are to be linked with 11 7 4 3 Number of input objects Options Setting option from 1 to 10 The parameter is used to set the number of input objects that are to be linked in the logic function Note If the parameter is set on 1 the logic function parameter is specified on NOT 11 7 4 4 Object type input x Options 1 bit 1 byte 1 bit The input object can take on value 0 or 1 1 byte The input o...

Страница 155: ...he logical value 1 The parameter is used to specify the value the input is to have after initial commissioning and after the return of voltage Thus no undefined states can arise 11 7 4 6 Logic input x Options Normal Inverse Normal The input signal of the channel is not inverted Inverse The input signal of the channel is inverted The parameter is used to invert the input signal of the channel Note ...

Страница 156: ...for the output object 11 7 4 8 Send output object Options With each input telegram With a change of the output object With each input telegram When a telegram is received via the input object the communication object always sends the value of the output object on the bus This also happens if the value of the output object has not changed With a change of the output object The communication object ...

Страница 157: ... True 0 When a logic has been met value 0 is present at communication object GFx output True 1 When a logic has been met value 1 is present at communication object GFx output The parameter is used to specify the value that is sent via the 1 bit communication object GFx output when a condition true has been met Note The parameter can only be set if the Object type output parameter is set on 1 bit a...

Страница 158: ...1 Untrue 0 When a logic has not been met value 0 is present at communication object GFx output Untrue 1 When a logic has not been met value 1 is present at communication object GFx output The parameter is used to specify the value that is sent via the 1 bit communication object GFx output when a condition untrue has been not been met Note The parameter can only be set if the Object type output par...

Страница 159: ...tput or also from Output to input provided the control input allows this Enabling via the control input can take place via an On telegram or an Off telegram If for example the Control input setting is set on ON telegram only telegrams from the input are transmitted to the output The condition is that the control input has received an On telegram It is also possible to block signals via the Filter ...

Страница 160: ...g travel up or down 1 bit stop adjust The value is sent as 1 bit switching commands e g travel stop adjust slats 2 bit priority The value is sent as 2 bit switching commands with priority 4 bit relative dimming The value is sent as 4 bit brightness step 1 byte 0 100 The value is sent as 1 byte value without a sign percentage value 0 0 255 100 1 byte 0 255 The value is sent as 1 byte value without ...

Страница 161: ...e bit size can be freely allocated This means that the first internal or external group address or action that is assigned and already connected to an other communication object will specify the size The set option fixes the bit size of the input and output object 11 7 5 3 Filter function Options Deactivated On filter out Off filter out Deactivated No telegrams are filtered out On filter out On te...

Страница 162: ...rections Telegrams are transferred in both directions The parameter is used to specify the direction in which the signal is to be transferred 11 7 5 5 Enable object Options Deactivated Activated Deactivated Object GFx control input is not enabled Activated Object GFx control input is enabled The function can be temporarily blocked via object Sx control input The 1 bit communication object GFx cont...

Страница 163: ...function Gate is blocked temporarily at the receipt of an On or Off telegram Note This parameter can only be set if the Enable object parameter is set on activated 11 7 5 7 Enable object after return of voltage Options Blocked Enabled Blocked The enable object is not activated after bus voltage recovery The blocking function is deactivated Enabled If the enable object was activated prior to bus vo...

Страница 164: ... phase The parameter is used to specify whether input signals are saved during the blocking phase The further behaviour depends on the setting of the Data flow direction parameter For example Data flow direction Input towards the output If the setting activated has been selected the output sends its value after the blocking phase if a telegram has been received on the input during the blocking pha...

Страница 165: ...te object GFx switch off prewarning time 2 byte object GFx output The objects GFx input and GFx output can take on size 1 bit or 1 byte depending on the object type selected Note The parameters for application staircase lighting can be called up via general parameters and extended parameters Note The number of the object GF1 GFx depends on the channel used 11 7 6 1 Channel name Entry Name The para...

Страница 166: ...legram 1 bit Two 1 byte objects for input and output When a value telegram is received via the GFx input object an adjustable switch off delay is started At the same time a telegram with the same value of the telegram 1 byte received on the input is sent via object GFx output After expiration of the switch off delay the GFx output object sends a telegram with value 0 1 byte The parameter is used t...

Страница 167: ...delay for movement detectors This always resets the switch off delay as long as movement is detected If telegrams with different values are received during the retriggering phase only the last value received is always sent via the GFx output object after expiration of the delay time 11 7 6 5 Switch off pre warning Options Deactivated Activated Deactivated The staircase lighting goes out without fl...

Страница 168: ...laced by the original output value after approximately one second Note This parameter can only be set if the Object type number parameter is set on Two 1 byte objects for input and output and parameter Switch off prewarning is set on activated 11 7 6 8 Overwrite switch off delay and switch off prewarning time during download Options Deactivated Activated Deactivated The switch off delay and switch...

Страница 169: ...bjects GFx input and GFx output can take on different sizes 1 bit 4 byte depending on the object type selected The bit sizes of objects GFx input and GFx output can be collectively adjusted for the different applications Note The parameters for application Delay can be called up via general parameters and extended parameters Note The number of the object GF1 GFx depends on the channel used 11 7 7 ...

Страница 170: ...ntage value 0 0 255 100 1 byte 0 255 The value is sent as 1 byte value without a sign Any value 0 255 2 byte float The value is sent as floating point value 671088 6 670760 9 e g temperature or moisture value 2 byte signed The value is sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e...

Страница 171: ... restarted when a telegram is received via the GFx input object The parameter is used to specify whether the switch off delay is restarted when a further telegram is received via object GFx input This behaviour is called retriggering For example a retriggering makes sense for a switch off delay for movement detectors This always resets the switch off delay as long as movement is detected If telegr...

Страница 172: ...d Filter value is sent direct others are sent delayed Only the filter value is sent direct All other values are sent delayed Filter value is suppressed other are delayed Only the filter value is blocked All other values are sent delayed The parameter can be used to specify a condition for the sending of filter values compared to all other values Note The parameter is only adjustable if the Filter ...

Страница 173: ...ons for selection 4 byte float Options Setting option from 4000000 to 4000000 Options for selection 4 byte signed Options Setting option from 2147483648 to 2147483647 Options for selection 4 byte unsigned Options Setting option from 0 to 4294967295 The value that is to be specifically observed is specified via the parameter The bit size depends on parameter Object type The connected Filter functio...

Страница 174: ...ivated The delay time will be overwritten when the device is reprogrammed A telegram with a new delay time s can be received via the 2 byte communication object GFx delay time The received 2 byte value is written to the memory of the device and is retained even after a power failure The parameter is used to specify whether the received storage value is to be retained for a reprogramming of the dev...

Страница 175: ...x output can be collectively adjusted for the different applications The application can send either the largest input value the smallest input value or the average of all input values via the output object The values are sent either at each input assignment or when the output object is changed Note The parameters for application Min max value transducer can be called up via general parameters Not...

Страница 176: ...s sent as 2 byte value with a sign 32768 32767 e g time difference or percentage difference 2 byte unsigned The value is sent as 2 byte value without a sign 0 65535 e g time or brightness value 4 byte float The value is sent as 4 byte floating point value physical values e g luminosity electric power pressure 4 byte signed The value is sent as 4 byte value with a sign 2147483648 2147483647 e g cou...

Страница 177: ... 8 5 Output object Options Adopts the largest value of the inputs Adopts the smallest value of the inputs Adopts the average value of the inputs Adopts the largest value of the inputs The largest value of all input telegrams is sent via the output object Adopts the smallest value of the inputs The smallest value of all input telegrams is sent via the output object Adopts the average value of the i...

Страница 178: ...For triggering different actuators the size of objects GFx actuator group x can be set via parameter Object type actuator group The user has the option of saving the scenes A corresponding save telegram must be received for this Note The parameters for the Light scene actuator application can be called up via general parameters configuration of actuator objects and configuration of scene x Note Th...

Страница 179: ...t consecutively via communication objects GFx actuator group x The sequence is strictly specified First the telegram of actuator group A is sent out then the telegram of actuator group B etc The parameter is used to set the delay time between the individual telegrams 11 7 9 5 Overwrite scenes at download Options Deactivated Activated Deactivated The scene values saved by the user remain in the dev...

Страница 180: ...led blocked true untrue 1 bit blind The value is sent as 1 bit switching commands e g travel up or down 1 byte 0 100 The value is sent as 1 byte value without a sign percentage value 0 0 255 100 Temperature The value is sent as 2 byte floating point value 671088 6 670760 9 The parameter is used to set the bit size of communication object GFx actuator group x for different applications 11 7 9 7 Sce...

Страница 181: ...et for the communication objects of the connected actuators these will send their current values to the device via an answer telegram The values are stored in the memory and overwrite the previous values These are also not lost in the event of a power failure 11 7 9 9 Actuator group x Options Deactivated Activated Deactivated The value of actuator group x is not sent at the call up of the scene Ac...

Страница 182: ...on 1 bit switching 11 7 9 12 Value Options Up Down Adjustable options when parameter Object type actuator group x is set on 1 bit blind 11 7 9 13 Value Options Setting option from 0 to 100 Setting option if parameter Object type actuator group x is set on 1 byte 0 100 11 7 9 14 Temperature Options Setting option from 33 5 to 93 5 Setting option if parameter Object type actuator group x is set on T...

Страница 183: ...Notes Product manual 2CKA001473B9488 183 12 Notes ...

Страница 184: ...ect values 93 128 Brightness of the colours 131 Brightness of the LED during blockage 48 53 C Channel name 147 152 153 159 165 169 175 178 Channel x Application 145 Cleaning 30 Colour concept 29 Colour for Off 131 Colour for On 132 Colour for Zone 1 corresponds to 0 133 Colour for Zone 2 starting at 1 134 Colour for Zone 3 135 Colour for Zone 4 up to 99 136 Colour for Zone 5 corresponds to 100 137...

Страница 185: ...3 129 Operation 29 Output default value true 157 Output default value untrue 158 Output object 177 Output sends 177 Overview 16 Overview of types 19 Overwrite scenes at download 179 Overwrite switchover time at download 52 Overwriting internal object 144 P Primary function Application 55 Proximity Application 47 Q Qualification of personnel 11 R Reaction on falling edge 58 65 82 87 Reaction on lon...

Страница 186: ...position down 71 118 Value for position up 71 118 Value for slats position down 72 119 Value for switch off prewarning 168 Value of the output object for logic true 157 Value of the output object for logic untrue 158 Value x for long operation 78 Value x for short operation 77 Versions 17 W Working mode of the buttons 118 122 125 127 Working mode of the buttons for dimming 67 113 Working mode of t...

Страница 187: ...ntents of this document without prior notice The detailed specifications agreed upon apply for orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or extracts thereof must not be reproduced transmitted or reused by third parties without pri...

Отзывы: