SAM600-MU - Parameter Setting
Group/ Pa
r
ame
t
er Name
I
I
E
D Va
l
ue
1
1--
---
----
-===========
"
SAM600-MU
v'
Paller system frequency
v'
Neutr
a
l phase
v'
D
i
g
i
tal inputs rated voltage
v'
Fuse fa
il
ure act
i
va
t
i
on
l
evel
v'
Test switch ac
t
i
vat
i
on level
v'
Open
I
RF contact on System Bus s
i
n
g
l
e redundancy
e,
v'
I
EEE 1588do
rna
i
n number
v'
Al
l
owed
I
naccuracy
v'
Time synch
r
on:isat
i
on mode
v'
I
E□ Configuration
v'
HW Configuration
v'
SAM600-VT 1
v'
Primary nom
i
nal transducer va
l
ue Ul
v'
Second,ary no
m
i
nal transducer va
l
ue Ul
v'
Primary nom
i
nal transducer value U2
v'
Second,ary no
m
i
na
l
transducer va
l
ue U2
v'
Primary nom
i
nal transducer va
l
ue U3
v'
Second,ary no
m
i
nal t
r
ansduce
r
va
l
ue U3
v'
Primary nom
i
nal transducer va
l
ue U4
v'
Second,ary no
m
i
na
l
transduce
r
va
l
ue U4
v'
Neutral phase
v'
D
i
g
i
tal inputs rated voltage
v'
Fuse fa
.
i
lure act
i
vat
i
on
l
eve
l
v'
Test sw
i
tch act
i
vat
i
on level
v'
SAM600-CT
1
v'
Primary no
m
i
nal transducer value IA
v'
Second,ary no
m
i
nal transducer va
l
ue IA
v'
Primary nom
i
nal transducer va
l
ue 1B
v'
Second,ary no
mi
nal t
r
ansduce
r
va
l
ue 1B
v'
Primary nom
i
nal t
r
ansduce
r
value IC
v'
Second,ary no
m
i
na
l
t
r
ansducer va
l
ue IC
v'
P
r
imary nom
i
nal transducer va
l
ue IN
v'
Second,ary no
m
i
nal t
r
ansduce
r
va
l
ue IN
v'
Neutral phase
(
I
PC Va
l
ue
I
Un
i
t
I
Min
I
Max
A
50
Hz
Ca
l
cu
l
ated
110
voe
Low poten
t
i
al
High potential
Fa
l
se
0
0
255
4
us
Free
r
unn
i
ng
-
110.00
kV
1.
00
1100
.
00
110
V
110.00
kV
1.
00
1100
.
00
110
V
110.00
kV
1.
00
1100
.
00
110
V
1
10.00
kV
1.
00
1100
.
00
110
V
Ca
l
cu
l
ated
110
voe
Low poten
t
i
al
High potent
i
al
1000
A
65000
A
1000
A
65000
A
1000
A
65000
A
1000
A
65000
A
Calcu
l
ated
�
Ill
•
IEC18000654 V1 EN-US
Figure 24: SAM600 System- Parameter Setting
5.1.1
SAM600 system parameters
GUID-CB5EA13C-6B99-45E1-A328-7ADBEAF1B649 v1
The organization of parameters in a tree structure is visible in the plant structure by expanding
the tree. For each function, parameters are organized in basic and advanced groups in which
the advanced settings are used for application optimization.
During the Common Write action, both basic and advanced settings are written
to a SAM600 system.
A SAM600 system supports up to three PTP access points. Each module
supports up to one PTP access point.
Section 5
1MRK 511 433-UEN B
SAM600 Engineering
26
SAM600 Process Bus I/O System
Engineering manual
© Copyright 2017 ABB. All rights reserved