background image

1.3.3 

Related documentation

Name of the document

Document ID

Application Engineering Guide

1MRS757394

Engineering Manual

1MRS757184

IEC 61850 Communication Protocol Manual

1MRS757260

Operation Manual

1MRS757183

Technical Manual

1MRS757256

Download the latest documents from the ABB Web site

http://www.abb.com/relion

.

1.4 

Symbols and conventions

1.4.1 

Symbols

The caution icon indicates important information or warning related
to the concept discussed in the text. It might indicate the presence of
a hazard which could result in corruption of software or damage to
equipment or property.

The information icon alerts the reader of important facts and
conditions.

The tip icon indicates advice on, for example, how to design your
project or how to use a certain function.

Although warning hazards are related to personal injury, it is necessary to understand
that under certain operational conditions, operation of damaged equipment may result
in degraded process performance leading to personal injury or death. Therefore,
comply fully with all warning and caution notices.

1.4.2 

Document conventions

A particular convention may not be used in this manual.

1MRS757261 E

Section 1

Introduction

PML630/Compact Load-Shedding Solution

5

Point List Manual

Содержание Relion 630 Series

Страница 1: ...RELION 630 SERIES Power Management PML630 Compact Load Shedding Solution IEC 61850 Point List Manual...

Страница 2: ......

Страница 3: ...Document ID 1MRS757261 Issued 2019 08 12 Revision E Product version 1 2 1 Copyright 2019 ABB All rights reserved...

Страница 4: ...bed in this document is furnished under a license and may be used copied or disclosed only in accordance with the terms of such license Trademarks ABB and Relion are registered trademarks of the ABB G...

Страница 5: ...ted and communicate data and information via a network interface which should be connected to a secure network It is the sole responsibility of the person or entity responsible for network administrat...

Страница 6: ...concerning electrical equipment for use within specified voltage limits Low voltage directive 2014 35 EU This conformity is the result of tests conducted by ABB in accordance with the product standar...

Страница 7: ...and symbols 6 Section 2 Logical node list 9 Logical nodes 9 Section 3 Logical node extensions 11 New logical nodes 11 LSCACLS 11 PSACLS 12 LSCCCLS 13 SNWLRCLS 13 SNWARCLS 14 LSCRCLS 15 Extended logic...

Страница 8: ...DCSWI 25 LDMMXU 25 PPLSGGIO 26 SPGGIO 27 DRRDRE 27 DPGGIO 28 MAPGAPC 28 CNTGGIO Revision 1 28 MVGGIO 29 SPVNZBAT 30 Section 4 Glossary 31 Table of contents 2 PML630 Compact Load Shedding Solution Poin...

Страница 9: ...anual addresses the communication system engineer or system integrator responsible for pre engineering and engineering the communication setup in a substation from a device s perspective The system en...

Страница 10: ...on for installation and commissioning manuals The PML630 documentation set includes only application engineering guide engineering manual IEC 61850 communication protocol manual IEC 61850 point list m...

Страница 11: ...esult in corruption of software or damage to equipment or property The information icon alerts the reader of important facts and conditions The tip icon indicates advice on for example how to design y...

Страница 12: ...r output signal name in the function block symbol given for a function indicates that the signal must be connected to another function block in the application configuration to achieve a valid applica...

Страница 13: ...n DPGGIO1 Multipurpose analog protection MAPGAPC1 Station communication GOOSE Binary receive GOOSEBINRCV Double point receive GOOSEDPRCV Integer receive GOOSEINTRCV Measured value receive GOOSEMVRCV S...

Страница 14: ...8...

Страница 15: ...ders L System logical nodes LPHD Physical device information LLN0 Logical node zero P Logical nodes for protection functions PTRC Load shedding trip command G Logical nodes for generic references GAPC...

Страница 16: ...10...

Страница 17: ...ding LN Prefix SubNetWork Load shed information RCLS SNWA SNWARCLS LN Class R for Load shedding Related function C for Contingency based LS for Load shedding LN Prefix SubNetWork Accumulated load powe...

Страница 18: ...E ACLS class ACLS Contingency load shedding Fast LS M Data Common logical node information Mod ABB_c_dINC Mode load shed function Enable Disable Test command status M Beh ABB_a_dINS Behaviour reflect...

Страница 19: ...load shedding related subnetwork information M Data Common logical node information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_b_dLPL Name plate M Measured...

Страница 20: ...shed priority E LSPrioRcd2 ABB_c_dSPS Record 2 subnetwork shed priority E LSPrioRcd3 ABB_c_dSPS Record 3 subnetwork shed priority E NgPwrBalSt ABB_c_dSPS Negative power balance status E 3 1 5 SNWARCL...

Страница 21: ...umulated load against priority 18 O ALodPrio19 ABB_c_dMV Accumulated load against priority 19 O Status information ManPrioSet ABB_b_dINS Manual load shed priority setting E 3 1 6 LSCRCLS Table 9 LSCRC...

Страница 22: ...CB5 E NtwNumCB6 ABB_b_dINS Subnetwork number of network CB6 E NtwNumCB7 ABB_b_dINS Subnetwork number of network CB7 E NtwNumCB8 ABB_b_dINS Subnetwork number of network CB8 E NtwNumCB9 ABB_b_dINS Subne...

Страница 23: ...rce MMTR PS PSMMTR Maximum demand and energy calculation for power source PTOC PS PSPTOC Power source over current function for load shed trigger initiation MMXU NP NPMMXU Power measurement for networ...

Страница 24: ...circuit breaker and power information Data Common Logical Node Information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_b_dLPL Name plate M 3 2 3 LSLLN0 Table...

Страница 25: ...etwork circuit breaker information Data Common Logical Node Information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_b_dLPL Name plate M 3 2 6 LSCLLN0 Table 1...

Страница 26: ...LLN0 LN0 for function information of data exchange between adjacent network area IED Data Common logical node information Mod ABB_a_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M Na...

Страница 27: ...iour M Health ABB_c_dINS Health M NamPlt ABB_b_dLPL Name plate M Status information Tr ABB_C_dACT Trip M 3 2 11 PSCSWI Table 21 PSCSWI Attribute name DATA type Explanation M O E CSWI class CSWI Power...

Страница 28: ...e above which demand shed started E OvLodPwr ABB_v2_dMV Overload amount E SLSMaxPwr ABB_v2_dMV Maximum power during slow load shed trigger E Status information GovModVal ABB_v1_dINS Generator governor...

Страница 29: ...nt based slow load shed of power source Data Common logical node information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_b_dLPL Name plate M Control Rs ABB_v...

Страница 30: ...16 NCBDCSWI Table 26 NCBDCSWI Attribute name DATA type Explanation M O E CSWI class CSWI Network circuit breaker data Data Common logical node information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviou...

Страница 31: ...e DATA type Explanation M O E CSWI class CSWI Load feeder Circuit Breaker position Data Common logical node information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamP...

Страница 32: ...node information Mod ABB_c_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_b_dLPL Name plate M Measurements RxLSPwr ABB_v2_dMV Received load shed power E RxSpRsvPwr ABB_v...

Страница 33: ...ATA type Explanation M O E RDRE class RDRE Load Shedding disturbance records Data Common logical node information Mod ABB_a_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB...

Страница 34: ...on M O E GAPC class GAPC Multipurpose analogue protection function M Data Common Logical Node Information Mod ABB_a_dINC Mode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_d_dLPL...

Страница 35: ...3 E Data type for counter value is INT32 INT128 is not supported Cnt4 ABB_v1_dBCR Output of counter 4 E Data type for counter value is INT32 INT128 is not supported Cnt5 ABB_v1_dBCR Output of counter...

Страница 36: ...ode M Beh ABB_a_dINS Behaviour M Health ABB_c_dINS Health M NamPlt ABB_a_dLPL Name plate M Status Vol ABB_b_dMV Battery voltage M BatHi ABB_a_dSPS Battery high voltage or charge overcharge O BatLo ABB...

Страница 37: ...bstation communication and modeling IED Intelligent electronic device LD0 Logical device zero 0 LHMI Local human machine interface LLN0 Logical node zero 0 LN Logical node M Mandatory data according t...

Страница 38: ...32...

Страница 39: ...33...

Страница 40: ...BB Distribution Solutions Distribution Automation P O Box 699 FI 65101 VAASA Finland Phone 358 10 22 11 www abb com mediumvoltage www abb com relion Copyright 2019 ABB All rights reserved 1MRS757261 E...

Отзывы: