background image

30

1MRS755312

Connectivity Packages

User’s Guide

REF 541/543/545

REM 543/545

RET 541/543/545

COIND4

ESW

XSWI

130

Object indication 4, non-
controllable

COIND5

ESW

CSWI

131

Switch controller

COIND5

ESW

XSWI

131

Object indication 5, non-
controllable

COIND6

ESW

CSWI

132

Switch controller

COIND6

ESW

XSWI

132

Object indication 6, non-
controllable

COIND7

ESW

CSWI

133

Switch controller

COIND7

ESW

XSWI

133

Object indication 7, non-
controllable

COIND8

ESW

CSWI

134

Switch controller

COIND8

ESW

XSWI

134

Object indication 8, non-
controllable

COPFC

PFC

ARCO

143

Power factor controller

Condition Monitoring

CMBWEAR1

CBEW

GGIO

187

Circuit breaker electric wear 1

CMBWEAR2

CBEW

GGIO

188

Circuit breaker electric wear 2

CMCU3

SCC

GGIO

181

Supervision function of the 
energizing current input circuit

CMGAS1

-

SIMG

186

Gas density monitoring

CMGAS3

-

SIMG

194

Gas density monitoring of three 
poles

CMSHED

CHED

GGIO

189

Scheduled maintenance

CMSPRC1

SPRC

GGIO

190

Spring charging control 1

CMTCS1

TCS

GGIO

191

Trip circuit supervision 1

CMTCS2

TCS

GGIO

192

Trip circuit supervision 2

CMTIME1

T

GGIO

184

Operate time counter 1 for the used 
operate time (motors)

CMTIME2

T

GGIO

185

Operate time counter 2 for the used 
operate time (motors)

CMTRAV1

TRT

GGIO

193

Breaker travel time 1 supervision

CMVO3

SVC

GGIO

182

Supervision of the energizing 
voltage input circuit

Measurement

MEAI1

GM

GGIO

213

General measurement 1

MEAI2

GM

GGIO

214

General measurement 2

MEAI3

GM

GGIO

215

General measurement 3

MEAI4

GM

GGIO

216

General measurement 4

MEAI5

GM

GGIO

217

General measurement 5

MEAI6

GM

GGIO

218

General measurement 6

MEAI7

GM

GGIO

219

General measurement 7

MEAI8

GM

GGIO

220

General measurement 8

MECU1A

I

MMXU

201

Current measurement A

Table 5.-1 LN prefixes for RED500  (Continued)

Function Block 
Name

IEC 61850 Logical Node Name

Description

Logical Node Prefix Logical Node Class

Logical Node 

Instance

(Channel Number)

Содержание REF 541

Страница 1: ...Connectivity Packages for REF 541 543 545 REM 543 545 RET 541 543 545 User s Guide...

Страница 2: ......

Страница 3: ...conventions 7 1 6 Terminology 8 1 7 Abbreviations 9 1 8 Related documents 9 1 9 Document revisions 9 2 Installation and uninstallation 11 2 1 Installing connectivity packages 11 2 2 Uninstalling conne...

Страница 4: ......

Страница 5: ...license Copyright 2005 ABB Oy All rights reserved 1 2 Trademarks ABB is a registered trademark of ABB Group All other brand or product names mentioned in this document may be trademarks or registered...

Страница 6: ...nt and usage of connectivity packages This user s guide is divided into following sections Installation and uninstallation This chapter describes the installation and the uninstallation of the connect...

Страница 7: ...rd key that is not labeled on the keyboard For example the space bar comma key and so on Press CTRL C indicates that you must hold down the CTRL key while pressing the C key to copy a selected object...

Страница 8: ...sily with the latest versions of the IED specific information connectivity package Software package that provides device specific information about certain protection and control relay IED which provi...

Страница 9: ...ording to IEC 61850 standard LON A communication protocol developed by Echelon SCL Substation Configuration description Language SPA ABB proprietary communication protocol used in substation automatio...

Страница 10: ......

Страница 11: ...extracts the installation files to your local computer 3 After the connectivity package installation program starts click Next to proceed see Fig 2 1 1 With the Back button you can return to the previ...

Страница 12: ...y Packages User s Guide REF 541 543 545 REM 543 545 RET 541 543 545 A050308 Fig 2 1 1 REF 541 543 545 Connectivity Package installation program 4 Follow the instructions of the installation wizard to...

Страница 13: ...dd or Remove Programs dialog from the Windows Control Panel 2 Select the relevant connectivity package and click Remove see Fig 2 2 1 You can check that you are uninstalling the right connectivity pac...

Страница 14: ......

Страница 15: ...orted applications and tools refer to Section 1 3 General and Section 1 8 Related documents A Connectivity Package Manager window shows the installed applications and tools as well as the installed co...

Страница 16: ...mouse or keyboard s arrow keys You can expand and collaps the nodes by clicking the and icons or pressing left and right arrow keys You can also use the commands from the View menu to expand and colla...

Страница 17: ...ng latest versions to unactive nodes If the connectivity package version has information about supported IEDs this information is shown in the text box under Supported IEDs see Fig 3 2 1 3 With this i...

Страница 18: ...ackage A050314 Fig 3 2 2 2 Adding connectivity package 2 Select a relevant connectivity package installer file msi 3 Click Open The installation program starts to install the selected connectivity pac...

Страница 19: ...e usage of connectivity packages in different products For more information on how to use connectivity packages in applications and tools refer to documentation related to each product Communication G...

Страница 20: ......

Страница 21: ...ee different parts LN prefix LN class and LN instance number LN prefix is an ABB specific string with less than five characters see the table below The LN class is the name of the logical node class d...

Страница 22: ...age DEF2High DEF RBRF 41 Circuit breaker failure protection of directional earth fault protection function high set stage DEF2Inst DEF PTOC 42 Directional earth fault protection function instantaneous...

Страница 23: ...n stage 1 Freq1St2 T1 PTOF 73 Overfrequency protection stage 2 timer 1 Freq1St2 T1 PTUF 73 Underfrequency protection stage 2 timer 1 Freq1St2_1 T2 PTOF 73 Overfrequency protection stage 2 timer 2 Freq...

Страница 24: ...earth fault protection function high set stage NEF1High EF RBRF 39 Circuit breaker failure protection of non directional earth fault protection function high set stage NEF1Inst EF PTOC 90 Non directi...

Страница 25: ...rotection stage 1 NUC3St1 PH RBRF 88 Circuit breaker failure protection of three phase non directional undercurrent protection stage 1 NUC3St2 PH PTUC 89 Three phase non directional undercurrent prote...

Страница 26: ...oltage PSV3St1_1 PS PTOV 112 Positive phase sequence overvoltage PSV3St2 NS PTOV 113 Negative phase sequence overvoltage PSV3St2 PS PTUV 113 Positive phase sequence undervoltage PSV3St2_1 PS PTOV 113...

Страница 27: ...ion low set stage UPOW6St1 PH PDIR 95 Three phase underpower or reverse power stage 1 UPOW6St1 PH PDUP 95 Directional underpower UPOW6St1 PH RBRF 95 Circuit breaker failure of three phase underpower o...

Страница 28: ...eaker failure protection of stabilized restricted earth fault protection low voltage side Diff6T GEN PDIF 106 Stabilized three phase differential protection for transformers Diff6T GEN RBRF 106 Circui...

Страница 29: ...nnector 2 switch control CODC2 DCO XSWI 123 Disconnector 2 disconnector information CODC3 DCO CILO 124 Disconnector 3 interlocking CODC3 DCO CSWI 124 Disconnector 3 switch control CODC3 DCO XSWI 124 D...

Страница 30: ...ensity monitoring of three poles CMSHED CHED GGIO 189 Scheduled maintenance CMSPRC1 SPRC GGIO 190 Spring charging control 1 CMTCS1 TCS GGIO 191 Trip circuit supervision 1 CMTCS2 TCS GGIO 192 Trip circ...

Страница 31: ...P MMXU 207 Three phase power metering MEVO1A U MMXU 205 Voltage measurement A MEVO1B U MMXU 226 Voltage measurement B MEVO3A U MMXU 204 Three phase voltage measurement A MEVO3B U MMXU 206 Three phase...

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...ABB Oy Substation Automation Products P O Box 699 FI 65101 Vaasa FINLAND Tel 358 10 22 11 Fax 358 10 224 1094 www abb com substationautomation 1MRS755312 EN 05 2005...

Отзывы: