78
FEM610 |
PROCESSMASTER | OI/FEM610-EN REV. A
12 . . .Specification
ProcessMaster – Material load for process
connections
The limits for the permissible measuring medium
temperature (Tmedium) and permissible pressure
(Pmedium) are calculated on the basis of the lining and
flange material used in the device (refer to the name plate
on the device).
Minimum permissible operating pressure
The following tables show the minimum permissible
operating pressure (P
medium
) depending on measuring
medium temperature (T
medium
) and the liner materiall.
Liner approvals on request; please contact ABB.
Lining material
Nominal
diameter
P
medium
[mbar abs]
T
medium
ETFE
1-4“
(DN 25 ... 100)
100
< 266 °F (130 °C)