WARNING – Bodily injury

. These symbols, and the signal word "WARNING", indicate a 

potentially dangerous situation. Failure to observe this safety information could result in death 

or severe injury. The text may state the hazard, how to avoid the hazard, and the result if not 

followed. The bolt is for electrical warnings; the exclamation point is for general warnings. 

 

 

NOTICE – Equipment damage or loss of data or cybersecurity risk.

 This symbol 

indicates a potential for equipment damage, loss of data or another unintended outcome. 

Failure to observe this information may result in damage to or destruction of the product 

and / or other system components. 

 

 

IMPORTANT NOTE: 

This symbol indicates operator tips, particularly useful information, or 

important information about the product or its further uses. 

 

Potential safety hazards 

 

 

DANGER – Serious damage to health / risk to life

.

 Ensure that there are no hazardous or 

flammable gases present in the immediate area of the analyzer. Protected enclosures that rely 

upon air purge and pressurization will be jeopardized when the protected air is removed. During 

this non-purged time, a danger exists for fire, explosion, damage to property, and injury or death 

to plant personnel. 

 

 

WARNING – Bodily injury. high voltage safety:

  The DBDID uses a high voltage alternating 

current discharge to create a plasma. The system operates at a high voltage and a low current 

which is applied to the glass reactor tube at the round metal electrodes. This electrode should be 

covered with the plasma shield whenever the plasma is operating. 
Before performing any maintenance procedures or adjustments to the plasma cell, make sure the 

power is off. The best way to do this is to remove the power pack from the main line. This will 

ensure that the plasma cell is not at voltage. 
If the center rod of the plasma supply is not connected to ground, the center rod will have 

voltage on it (approx. 40 Volts) and 

it will shock maintenance personnel. 

It will also spark 

when connecting the ground wire to the center electrode; 

do not do this in a hazardous 

environment. 

ABB recommends turning the plasma power off, allowing a minimum of 20 

seconds for the DBDID to discharge and then connecting the center electrode to ground. If done 

in the proceeding manner, the center electrode will not spark. 

 

 

DANGER – Serious damage to health / risk to life

.

 Ensure there is no hazardous atmosphere 

present when performing maintenance on the unit. Do not separate components when energized. 

This applies to all connectors and connections, cabling and wiring.  

 

 

NOTICE – Equipment damage or loss of data.

 Printed circuit boards and other electronics are 

electrostatic discharge sensitive. Ensure that proper ESD measures are taken, as defined by 

location.  

 

 

 

!

Содержание PGC5000 Series

Страница 1: ...ABB MEASUREMENT ANALYTICS 892J009MNAE PGC5000 Gas Chromatograph Dielectric Barrier Discharge Ionization Detector DBDID SERVICE INSTRUCTION Measurement made easy...

Страница 2: ...Symptom Spikes 11 4 Specifications 12 4 1 Physical 12 4 2 Power 12 4 3 Modes of operation 12 4 4 Detector sensitivity 12 4 5 Gas consumption 12 5 Drawings 12 List of Figures Figure 1 1 Dielectric Bar...

Страница 3: ...d safety regulations concerning the construction and operation of electrical installations The regulation on technical working materials safety guidelines for tools The regulations and recommendations...

Страница 4: ...DBDID uses a high voltage alternating current discharge to create a plasma The system operates at a high voltage and a low current which is applied to the glass reactor tube at the round metal electr...

Страница 5: ...high voltage alternating current applied to a gas as it flows through a dielectric material The gas is typically helium or argon and the dielectric material is a quartz or Pyrex tube Two electrodes a...

Страница 6: ...injury High voltage present Make sure that power to the PGC5000 has been disconnected before removing the detector To remove the detector from the PGC5000 perform the following steps Disable the isoth...

Страница 7: ...t the coax cable item 1 in Figure 2 3 from the DBDID amplifier assembly Figure 2 3 DBDID amplifier assembly 1 On the DBDID power supply board unplug the high voltage power connector J2 item 3 the bias...

Страница 8: ...g the correct flow 1 Set flows by measuring the flow at the cell vent tube Refer to the data pack for correct flows The detector should automatically light when power is applied To verify remove the f...

Страница 9: ...ee the last page of this instruction for contact information Always include the information listed in Equipment Identifications and Configuration Identification in your request When ordering parts for...

Страница 10: ...a tube in a dark environment There should be a pink or almost white glow in the plasma tube If the tube is blue and the signal is low there is nitrogen in the plasma Verify that the correct reaction g...

Страница 11: ...system 3 6 Symptom Baseline drift Possible Cause Action s Poor pressure control Pressure controls not providing a consistent pulse free flow rate to the detector can cause detector drift Monitor the p...

Страница 12: ...ed Argon ionization mode AID In this mode the detector is not sensitive to fixed gases and methane but is sensitive to a wide range of organic and inorganic volatile components It is capable of ionizi...

Страница 13: ...to optional purge system 2 Reaction gas inlet plasma gas 3 Purge gas vent Detector assembly purge not used in most applications Flameproof breather must remain open or connected to optional purge syst...

Страница 14: ...14 DBDID 892J009MNAE Figure 5 3 Diagram flow PGC5000 air and carrier...

Страница 15: ...892J009MNAE DBDID 15 Figure 5 4 PGC5000 oven electronics internal connections diagram sheet 1...

Страница 16: ...16 DBDID 892J009MNAE Figure 5 5 PGC5000 oven electronics internal connections diagram sheet 2...

Страница 17: ...echnical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility whatsoever for...

Отзывы: