2TLC172287M0201
Rev B
28
www.abb.com/jokabsafety
2015-09-17
Display
LED
OSSD
ON
LED
OSSD
OFF
LED
FIRST
(yellow)
LED
LAST
(yellow)
Condition
Alignment
status
OFF
ON
ON
ON
First
not OK
Last
not OK
Not aligned
OFF
ON
First
OK
Last
not OK
OFF
OFF
First
OK
Last
OK
Middle optics not OK
ON
OFF
OFF
OFF
Each beam is over the min. operating
light reception threshold and the
number of beams over the light
reception threshold is between 0 and
25%
MINIMUM
alignment
ON
OFF
OFF
OFF
Each beam is over the min. operating
light reception threshold and the
number of beams over the light
reception threshold is between 25 and
50%
ON
OFF
OFF
OFF
Each beam is over the min. operating
light reception threshold and the
number of beams over the light
reception threshold is between 50 and
75%
ON
OFF
OFF
OFF
Each beam is over the min. operating
light reception threshold and the
number of beams over the light
reception threshold is between 75 and
100%
MAXIMUM
alignment
1) Keep the receiver in a steady position and adjust the transmitter until the yellow LED (
FIRST) turns off. This
condition shows the alignment of the first synchronisation beam.
2) Rotate the transmitter, pivoting around the lower optics axis, until the yellow LED ( LAST) turns off.
NB: Make sure that the green LED (
) is on and steady.
3) Slightly turn both units both ways to find the limits of the area in which the green LED (
) is
steady and “4”
is displayed (Maximum alignment). Place both units in the centre of this area.
4) Fix the two units firmly using brackets.
Check that the green LED (
) on the receiver is on when the beams are not interrupted. Then check that
the red LED (
) turns on when one single beam is interrupted. This check shall be made with the special
cylindrical “Test Piece” having a suitable size for the resolution of the device used (see paragraph 3.3 –
“Checks after first installation”).
5) Switch the device off and on to normal operating mode.
The alignment level is also monitored during normal operating mode and visualized on the display (see
paragraph 8.2
Once the AOPD has been aligned and correctly fastened, the signal on the display is useful both to check the
alignment and to show a change in the environmental conditions (presence of dust, light disturbance and so on).
Содержание Orion1 Base
Страница 23: ...2TLC172287M0201 Rev B 23 www abb com jokabsafety 2015 09 17 Figure 19 Connection to a Pluto B20 Safety PLC...
Страница 25: ...2TLC172287M0201 Rev B 25 www abb com jokabsafety 2015 09 17 Figure 22 Time chart of the OSSD outputs...
Страница 41: ...2TLC172287M0201 Rev B 41 www abb com jokabsafety 2015 09 17 14 EC Declaration of conformity...