4.5 Function tests
4.5.1 Function test of emergency stop
Overview
Validate the function of the FlexPendant emergency stop device.
Note
Also perform the test for any additional emergency stop devices.
Performing the function test
Note
Action
If any damage is found on the emergency
stop device, it must be replaced.
Make a visual inspection of the emergency
stop device to make sure it is not physically
damaged.
1
Pull and rotate the emergency stop device
clockwise to verify that it is not pressed in.
2
Power on the robot.
3
The test is passed if the event message
10013 Emergency stop state
appears in
the event log.
Note
For collaborative robots, the event mes-
sage
90518 Safety controller Emergency
stop triggered
appears by default. The
message
10013 Emergency stop state
is
also available in the event log.
Press the emergency stop device on the
FlexPendant.
Note
If the event message
20223 Emergency
stop conflict
appears in the event log, or
the event message
10013 Emergency stop
state
(and
90518 Safety controller Emer-
gency stop triggered
for collaborative ro-
bots) does not appear, then the test has
failed and the root cause of the failure must
be found.
4
Release the emergency stop device to re-
set the emergency stop state.
5
212
Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
4 Maintenance
4.5.1 Function test of emergency stop
Содержание OmniCore C30
Страница 1: ...ROBOTICS Product manual OmniCore C30 ...
Страница 2: ...Trace back information Workspace 22B version a4 Checked in 2022 06 01 Skribenta version 5 5 019 ...
Страница 562: ...This page is intentionally left blank ...
Страница 566: ...This page is intentionally left blank ...
Страница 574: ...This page is intentionally left blank ...
Страница 604: ......
Страница 605: ......