                CAUTION - Minor injuries

                 

Only qualified and authorized personnel are to be tasked 

with the installation, electrical connection, commissioning and 
maintenance of the transmitter. Qualified personnel are those 
individuals who have experience in the installation, electrical con-
nection, commissioning and operation of the transmitter or simi-
lar devices and hold the necessary qualifications. These qualifica-
tions include:

— Training or instruction – authorization to operate and maintain 
devices or systems according to safety engineering standards for 
electrical circuits, high pressures and aggressive media

— Training or instruction in accordance with safety engineering 
standards regarding maintenance and use of adequate safety 
systems.

For reasons of safety, ABB recommends that only sufficiently 
insulated tools, conforming to IEC EN 60900, be used.

Since the transmitter may form a link within a safety chain, it is 
recommended that the device be replaced immediately if defects 
are detected. In the event of use in a hazardous area, only non-
sparking tools shall be used.

2.2 Safety information for electrical installation 

                  WARNING – Bodily Injury. 

                  Electrical  connections  may  only  be  established  by  

authorized personnel in accordance with the electri-

cal  circuit  diagrams.  The  electrical  connection  information  in 
the  manual  must  be  observed;  otherwise,  the  application 
protection  type  may  be  affected.  Ground  the  measurement 
system according to requirements.

2.3 Safety information for inspection and maintenance

Corrective maintenance work may be performed only by trained 
personnel.

Before removing the device, depressurize the vessel and any 
adjacent lines or containers.

Check whether hazardous materials have been used as measured 
materials before opening the device. Residual amounts of haz-
ardous substances may still be present in the device and could 
escape when the device is removed from the vessel

Within the scope of operator responsibility, check the following 
as part of a regular inspection: 

Pressure-bearing walls/lining of the level device 

Measurement-related function 

Leak-tightness 

Wear (corrosion)

2.4 Operator liability

In instances where corrosive and / or abrasive materials are be-

ing measured, the user must check the level of resistance of all 

parts that are coming into contact with these materials. ABB 

offers guidance in the selection of material but does not accept 

liability in performing this service. The user must strictly observe 

the applicable national regulations with regards to installing, 

functional testing, repairing and maintaining electrical devices.

2.5 Qualified personnel

Installing, commissioning and maintaining the device may be per-
formed only by trained personnel who are authorized by the plant 
operator. These trained personnel must have read and understood 
this manual and must comply with its instructions

2.6 Mounting

Read the following installation instructions carefully before pro-
ceeding. Failure to observe the warnings and instructions may 
cause a malfunction or personal hazard. Before installing the trans-
mitter, ensure the device design meets the requirements of the 
measurement point from both a measure technology and safety 
point of view.

This applies in respect to:

Explosion-protection certification

Measuring range

Pressure

Temperature

Operating voltage

Check the suitability of the materials in regards to their resistance 
to the media. This applies to the:

Gasket

Process connection and seals

Probe

End connection

In addition, the relevant directives, regulations, standards and acci-
dent prevention regulations must be observed. Measurement ac-
curacy is largely dependent on the correct installation of the level 
transmitter and, if applicable, mounting arrangement. In instances 
where it is possible, the measuring setup should be free from criti-
cal ambient conditions such as large variations in temperature, 
vibrations or shocks.

2.7 Certification nameplates

Please refer to the 3.0

 

of this manual for details.

                 IMPORTANT 

                 Read  this  manual  thoroughly  before  using  this  equip-
ment. If you do  not  understand  the content of this  manual,  con-
tact ABB service personnel.

Содержание MT series

Страница 1: ...information Overview Electrical installation and ratings Explosive atmosphere markings Special conditions of use Routine maintenance tests Installation drawings EU declaration of conformity Certification for SIL 3 Capable State of the art loop powered 4 20 mA output guided wave radar transmitter for liquid level applications K TEK Products ...

Страница 2: ...sive Atmosphere markings 6 3 1 IECEx IS markings 6 3 2 IECEx Flameproof markings 6 3 3 FM US HazLoc markings 7 3 4 CSA Canada HazLoc markings 7 4 Safety informa on for inspec on and maintenance 8 4 1 Personnel qualifica ons 8 4 2 MT5X00 Alarm Levels and Dangerous Undetected Failure Rates Calcula on 8 4 3 Alarm Levels to be Programmed in Logic Solver 8 4 4 Use of Cri cally Restricted CR Mode for Saf...

Страница 3: ...ctrical systems and the relevant standards regulations and guidelines concerning explo sion protection 1 4 Information on WEEE Directive 2002 96 EC Waste Electrical and Electronic Equipment This product solution is not subject to the WEEE Directive 2002 96 EC or corresponding national laws e g the ElektroG Electrical and Electronic Equipment Act Germany Dispose of the product solution at a special...

Страница 4: ...lowing as part of a regular inspection Pressure bearing walls lining of the level device Measurement related function Leak tightness Wear corrosion 2 4 Operator liability In instances where corrosive and or abrasive materials are be ing measured the user must check the level of resistance of all parts that are coming into contact with these materials ABB offers guidance in the selection of materia...

Страница 5: ...ive environments 2 12 General guidelines WARNING Make sure all circuits are de energized prior to installation The MT series has been evaluated as an Installation Over voltage Category 1 Pollution Degree 2 apparatus per IEC 61010 The maximum altitude of operation is 6560 feet 2000 me ters The MT series is designed with both internal and external protective earth ground terminals All field wiring c...

Страница 6: ...ll be fitted to the input terminals Refer to ABB Instruction docu ment The cable entry device shall comply with the requirements of IEC 60079 0 and maintain IP 54 or better b Conditions of Manufacture Equipment with ic ia intrinsic safety shall be fitted with the MT Series Hermetic Seal Adapter Conditions of Certification a Special Conditions for safe use When EPL Ga or Da is required for example ...

Страница 7: ...e electrical equipment produced complies with the documentation Conditions of Certification a Special Conditions for safe use For explosion proof and Division 2 models with the symbol Ex ia and the words Associated Equipment always open circuit before removing covers For Intrinsically Safe models with the symbol Ex ia and the words INTRINSICALLY SAFE installations shall comply with the installatio...

Страница 8: ... by setting of diagnostic bits in HART protocol output 4 All MT5000 FMEDA analysis is based on using a safety accuracy of 2 5 The internal diagnostics are designed to achieve a Safe Failure Fraction of 90 minimum 6 The target average probability of failure on demand is less than 1 5 x 10 3 7 MT5000 transmitters are qualified for use in a SIS only when the output used for the safety function is the...

Страница 9: ...or remove it from service based on an LCD failure 4 7 3 Output Checkout The MT5000 can be equipped to provide level indication through the 4 20mA output HART communications and Foundation Fieldbus Only transmitters that are specified to output 4 20mA may be used in a Safety Implemented System The HART communication capabil ity of the 4 20mA transmitter will only be used for configuration and proof...

Страница 10: ...cement 4 8 Verify Proper Power up of the Transmitter Use a mA meter to measure the output current When power is applied the output should go to 4 00 mA for at least 1 second and then to either the measured level or an alarm condition out put If this does not happen the transmitter may not be receiv ing enough power or the main electronic is defective Excessive current above 21 mA is also an indica...

Страница 11: ... can be found on the web site at https library abb com and searching for certificate Exida SIL ABB 16 12 C118 C001 MT5000 Series IMPORTANT NOTE The user is responsible of verifying that current failure rates shown on the certificate meet the Safety Instrumented Function SIF ...

Страница 12: ...12 7 Typical Wiring Drawing ...

Страница 13: ...13 8 Installation Drawings for Intrinsic Safety Standard Wiring Reference ABB drawing ELE9021 MT5000 Series Intrinsically Safe Electrical Interconnection Diagram ...

Страница 14: ...14 8 Installation Drawings for Intrinsic Safety Standard Wiring Reference ABB drawing ELE1034 MT5000 Series FM CSA Intrinsically Safe Electrical Interconnection Diagram ...

Страница 15: ...make technical changes or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure...

Отзывы: