1-2   General Information

MN1950WEN

Product Notice

Only qualified personnel should attempt the start-up procedure or troubleshoot this equipment.
This equipment may be connected to other machines that have rotating parts or parts that are
controlled by this equipment. Improper use can cause serious or fatal injury.

Safety Notice

Intended use: Drives incorporating this product are intended for use in stationary ground based
applications in industrial power installations according to the standards EN60204 and VDE0160.
They are designed for machine applications that require variable speed controlled three-phase
brushless AC motors. These drives are not intended for use in applications such as:

Home appliances

Medical instrumentation

Mobile vehicles

Ships

Airplanes.

Unless otherwise specified, the drive is intended for installation in a suitable enclosure. The
enclosure must protect the drive from exposure to excessive or corrosive moisture, dust and dirt or
abnormal ambient temperatures. The installation, connection and control of drives is a skilled
operation, disassembly or repair must not be attempted. In the event that a drive fails to operate
correctly, contact the place of purchase for return instructions.

Precautions

Do not touch any circuit board, power device or electrical connection before you first
ensure that no high voltage is present at this equipment or other equipment to which it is
connected. Electrical shock can cause serious or fatal injury. Only qualified personnel
should attempt to start-up, program or troubleshoot this equipment.

MEDICAL DEVICE / PACEMAKER DANGER: Magnetic and electromagnetic fields in the
vicinity of current carrying conductors and industrial motors can result in a serious health
hazard to persons with cardiac pacemakers, internal cardiac defibrillators,
neurostimulators, metal implants, cochlear implants, hearing aids, and other medical
devices. To avoid risk, stay away from the area surrounding a motor and its current
carrying conductors.

Electrical components can be damaged by static electricity. Use ESD (electrostatic
discharge) procedures when handling this device.

To prevent equipment damage, be certain that input and output signals are powered and
referenced correctly.

To ensure reliable performance of this equipment, be certain that all signals are shielded
correctly.

WARNING

!

WARNING

!

CAUTION

!

CAUTION

!

CAUTION

!

Содержание MotiFlex e100 OPT-MF-005

Страница 1: ...MN1950 Digital I O Option ...

Страница 2: ......

Страница 3: ... General Information 2 Introduction 2 1 Digital I O option features 2 1 2 1 1 Installation 2 1 3 Input Output 3 1 Introduction 3 1 3 1 1 Slot selection and input output numbering 3 1 3 1 2 Digital inputs 3 3 3 1 3 Digital outputs 3 4 ...

Страница 4: ...ii Contents MN1950WEN ...

Страница 5: ...itness for any particular purpose The information in this document is subject to change without notice ABB assumes no responsibility for any errors that may appear in this document Mint is a registered trademark of Baldor a member of the ABB group Windows XP Windows Vista and Windows 7 are registered trademarks of the Microsoft Corporation UL and cUL are registered trademarks of Underwriters Labor...

Страница 6: ...repair must not be attempted In the event that a drive fails to operate correctly contact the place of purchase for return instructions Precautions Do not touch any circuit board power device or electrical connection before you first ensure that no high voltage is present at this equipment or other equipment to which it is connected Electrical shock can cause serious or fatal injury Only qualified...

Страница 7: ...on Before touching the option card be sure to discharge static electricity from your body and clothing by touching a grounded metal surface Alternatively wear an earth strap while handling the card 1 Choose carefully which of the option slots top or bottom to use The choice will often depend on the best route for the wiring that will lead to the option card 2 Pull off the drive s top or bottom fro...

Страница 8: ...icks into place The option card s external connector plate should finish approximately level with the 8 posts along the edge of the option slot 6 Insert the retaining screw and tighten If the screw will not locate in the threaded socket on the option card then check the position of the option card The screw must be fitted since it provides mechanical support and an electrical chassis connection fo...

Страница 9: ...lot 2 The numbering of bank 1 slot 1 inputs and outputs always starts at 32 since 0 31 are reserved by bank 0 even though only DIN0 DIN2 and DOUT0 DOUT1 are used by a standard MotiFlex e100 The numbering of bank 2 slot 2 inputs and outputs always starts at 64 since 0 31 are taken by bank 0 and 32 63 are taken by bank 1 This numbering system is summarized in the following table and in Figures 3 1 a...

Страница 10: ...32 7 DIN33 8 DIN34 9 DIN35 10 DIN36 11 DIN37 12 13 DOUT32 14 DOUT33 15 DOUT34 16 DOUT35 17 Shield 18 Shield 19 DIN32 20 DIN33 21 DIN34 22 DIN35 23 DIN36 24 DIN37 PCB this side DOUT64 1 DOUT65 2 DOUT66 3 DOUT67 4 Shield 5 Shield 6 DIN64 7 DIN65 8 DIN66 9 DIN67 10 DIN68 11 DIN69 12 13 DOUT64 14 DOUT65 15 DOUT66 16 DOUT67 17 Shield 18 Shield 19 DIN64 20 DIN65 21 DIN66 22 DIN67 23 DIN68 24 DIN69 PCB t...

Страница 11: ...int keywords including RESETINPUT ERRORINPUT and STOPINPUT can be used in the command window The state of these specially configured digital inputs can then be viewed using the Mint WorkBench Spy window s Axis tab The state of all digital inputs can also be viewed using the Spy window s I O tab See the Mint help file for details Figure 3 4 Digital input typical connection from an ABB NextMove e100...

Страница 12: ... is to protect the output from the back EMF generated by the relay coil when it is de energized The sense of the output can be configured in Mint WorkBench and its state is displayed in the Spy window Figure 3 5 DOUT32 64 digital output circuit When the MotiFlex e100 is connected to Mint WorkBench the active level of an output can be configured using the Digital I O tool Alternatively the Mint key...

Страница 13: ...l power consumption of the Digital I O option card is 0 5 W See the main MotiFlex e100 installation manual MN1943WEN for further details about the option slots power supply and derating information 13 1 8 9 TLP127 TLP280 DOUT32 64 DOUT32 64 DIN4 CREF1 100R 6k2 OPT MF 005 Digital I O User supply 24 V User supply GND NextMove e100 controller ...

Страница 14: ...3 6 Input Output MN1950WEN ...

Страница 15: ...MN1950WEN Input Output 3 7 ...

Страница 16: ...3 8 Input Output MN1950WEN ...

Страница 17: ...et us know Write your comments in the space provided below remove this page from the manual and mail it to Manuals ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol BS32 0BF United Kingdom Alternatively you can e mail your comments to manuals uk baldor com Comment continued ...

Страница 18: ...Comments MN1950WEN Thank you for taking the time to help us ...

Страница 19: ......

Страница 20: ...USA Telephone 262 785 3200 1 800 HELP 365 Fax 262 780 5135 www abb com drives ABB Beijing Drive Systems Co Ltd No 1 Block D A 10 Jiuxianqiao Beilu Chaoyang District Beijing P R China 100015 Telephone 86 10 5821 7788 Fax 86 10 5821 7618 www abb com drives ABB Ltd Motion Control 6 Bristol Distribution Park Hawkley Drive Bristol BS32 0BF United Kingdom Telephone 44 0 1454 850000 Fax 44 0 1454 859001 ...

Отзывы: