62
LMT10 0 A N D LMT 20 0 |
M AG N E TOS T R I C T I V E L E V EL T R A N SM I T T ER S | FF O I/L M T 10 0/ 2 0 0/FF - EN R E V. A
Menu: Device Info (continued)
Menu/Parameter
Value Range
Description
Device Info/Serial Number
Serial Number
14 digit Alphanumeric value 3K78
Indicates specific device identification number
Device Info/Device Configuration
Device Configuration
1 Level
1 Level + Temperature
2 Levels
2 Temperature
Default: 1 Level
Defines the application use of the device, users
can change the measurement from single level to
two levels However, if the device is not equipped
with an RTD, then the temperature option will not
be available
Device Info/Mount Orientation
Mount Orientation
Top, Bottom Default: Top
Physical mounting position of housing to probe
Device Info/Sensor
Sensor ID
ABB FE01
Type
Magnetostrictive
Device technology
Probe Length
0-3500 cm
SW Version
xx xx xx
HW Version
xx xx xx
FPGA Version
xx xx xx
Sensor Low Limit
-0.2 * probe length
Default: -700.0 cm
Sensor High Limit
1.2 * probe length
Default: 4200.0 cm
Sensor Offset
Default: 0.0 cm
Device Info/Electronics
SW Version
xx xx xx
HW Version
xx xx xx
Device Info/Display
SW Version
xx xx xx
HW Version
xx xx xx