  L A SER L E V EL T R A N SM I T T ER  |  C I/L LT 10 0 - EN R E V. A

3  Mounting

Install away from falling  

material for easiest  

configuration

For solids laser beam can  

be aimed at any angle 

 

Also typically applies to other 

scattering surfaces such as 

slurries  and some turbulent 

liquids

For typical liquid applications  

laser beam must be as 

perpendicular as possible,  

not exceeding 90° ± 5° to  

the surface

4  Easy setup

Rotate the housing: unscrew the stop tang-screw by 
approximately 1 rotation (do not pull it out) before removing 
the housing.  When the desired position is reached,  
re-tighten the stop tang-screw.

Connect the cables (15.5 to 42 V DC) to the LLT100 laser level 
transmitter – if using HART the minimum input voltage is 
21 V DC. 

Power on the transmitter.

Press the 

Right

 arrow key (

) on the display and select your 

access level using the 

Up

 and 

Down

 arrow keys ( ). 

Set the main parameters at the 

Easy Setup

 menu:

Select the required language.

Select the measurement mode:  
standard, clear liquid, positioning or dust/vapor.

Enter the vessel height (URP).

Set the sensor offset from the vessel top.

Select the primary variable (PV) for the 4 to 20 mA output: 
level, ullage, volume.

Choose the unit of the primary variable (PV):  
m, cm, mm, ft.

Set the value for vessel empty (LRV).

Set the value for vessel full (URV).

Enable or disable the filling rate.

Enter the Tag name.

Once the settings are completed, press 

Exit

 to return to the 

Distance view. 

Refer to Operating Instruction 

OI/LLT100-EN

 for detailed 

configuration / setup information.

Exit

Select

Easy Setup

Menu