5 YEAR WARRANTY FOR: 

KM26 Magnetic Liquid Level Gauges; MagWave Dual Chamber System; LS Series Mechanical Level Switches (LS500, LS550, 
LS600, LS700, LS800 & LS900); EC External Chambers and ST95 Seal Pots.  
 

3 YEAR WARRANTY FOR: 

KCAP300 & KCAP400 capacitance switches. 
 

2 YEAR WARRANTY FOR: 

AT100, AT100S and AT200 series transmitters; VF20 and VF30 vibrating fork switches; RLT100 and RLT200 reed switch level  
transmitters;  TX, TS, TQ, IX and IM thermal dispersion switches; IR10 and PP10 External Relays; MT2000 radar level transmit-
ters; RI100 Repeat Indicator; KP paddle switches; A02, A75 & A77 RF capacitance level switches and A38 RF capacitance level 
transmitters; Buoyancy Level Switches (MS50, MS10, MS8D & MS8F); Magnetic Level Switches (MS30, MS40, MS41, PS35 & 
PS45). 
 

1 YEAR WARRANTY FOR: 

KM50 gauging device; AT500 and AT600 series transmitters; LaserMeter and SureShot series laser transmitters; LPM200 digital 
indicator; DPM100 digital indicators; APM100 analog indicators; KVIEW series digital indicators and controllers; SF50 and SF60 
vibrating fork switches, KB Electro-Mechanical Continuous Measuring Devices, KSONIK ultrasonic level switches, transmitters & 
transducers. 
 

SPECIAL WARRANTY CONSIDERATIONS:

 

K-TEK does not honor OEM warranties for items not manufactured by K-TEK (i.e. Palm Pilots).  These claims should be handled 
directly with the OEM. 
 
K-TEK will repair or replace, at K-TEK’s election, defective items which are returned to K-TEK by the original purchaser within the 
period specified above from the 

shipment  date 

of the item and which is found, upon examination by K-TEK, to its satisfaction, to 

contain defects in materials or workmanship which arose only under normal use and service and which were not the result of ei-
ther alterations, misuse, abuse, improper or inadequate adjustments, applications or servicing of the product.  

K-TEK’s  warranty 

does not include onsite repair or services.  

Field service rates can be supplied on request. 

 
If a product is believed to be defective, the original purchaser shall notify K-TEK and request a Returned Material Authorization 
before returning the material to K-TEK, with transportation 

prepaid

 by the purchaser.  (Request door to door delivery via New 

Orleans International Airport located in Louisiana, USA.)  The product, with repaired or replaced parts, shall be returned to the 
purchaser at any point in the world with transportation prepaid by K-TEK for best-way transportation only.  K-TEK is not responsi-
ble  for  expedited shipping  charges.    If  the  product  is  shipped  to  K-TEK  freight  collect,  then  it  will  be  returned  to  the  customer 
freight collect. 
 
If inspection by K-TEK does not disclose any defects in material or workmanship, K-TEK’s normal charges for repair and ship-
ment shall apply (minimum 250.00 USD). 
 
The materials of construction for all K-TEK products are clearly specified and it is the responsibility of the purchaser to determine 
the compatibility of the materials for the application.   
 
THE FOREGOING WARRANTY IS K-TEK'S SOLE WARRANTY AND ALL OTHER WARRANTIES EXPRESSED, IMPLIED, OR 
STATUTORY,  INCLUDING  ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY  OF  FITNESS  FOR  A  PARTICULAR  PUR-
POSE, ARE EXCLUDED AND NEGATED TO THE MAXIMUM EXTENT PERMITTED BY LAW.  NO PERSON OR REPRESEN-
TATIVE IS AUTHORIZED TO EXTEND ANY OTHER WARRANTY OR CREATE FOR K-TEK ANY OTHER LIABILITY IN CON-
NECTION WITH THE SALE OF K-TEK’S PRODUCTS.  THE REMEDIES SET FORTH IN THIS WARRANTY ARE EXCLUSIVE 
OF ALL OTHER REMEDIES  AGAINST K-TEK.  K-TEK SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, 
OR SPECIAL DAMAGES OF ANY KIND.  K-TEK’S SOLE OBLIGATION SHALL BE TO REPAIR OR REPLACE PARTS (FOUND 
TO BE DEFECTIVE IN MATERIALS OR WORKMANSHIP) WHICH ARE RETURNED BY THE PURCHASER TO K-TEK. 

Содержание K-TEK AccuTrak AT500

Страница 1: ...AT500 0200 1b 10 2010 DCN0528 ...

Страница 2: ...tting 4 2 4 1 Setting ALARM to 3 6 mA Low Alarm 5 2 4 2 Setting ALARM to 21 mA High Alarm 5 2 5 4 mA 20 mA DAC Trim 5 2 5 1 Setting 4 0 mA DAC Trim 5 2 5 2 Setting 20 0 mA DAC Trim 5 3 TROUBLESHOOTING INFORMATION 7 3 1 Proper Powerup 7 3 2 Output Stability 7 3 3 Conversion from AT500 to AT600 or AT600 to AT500 7 4 APPENDIX A 8 4 1 Installation Drawings 8 5 APPENDIX B 10 5 1 FMEDA Certificate 10 6 ...

Страница 3: ...ff of the magnet assembly within the float riding on the sensor tube 2 INSTALLATION AND STARTUP WARNING When fitted with a compression fitting the sensor tube is shipped with a set of TEFLON ferrules and a set of STAINLESS STEEL ferrules in a separate bag The TEFLON ferrules are only in tended for low pressure applications for higher operating pressures and or permanent installation replace the TE...

Страница 4: ...d 2 3 Reversing Action If required transmitter output can be reversed by following these steps Note this reverses the 4 20 mA output Bring the level to 50 or 10 Enter the calibration mode by placing Magnet at position X for 2 seconds Slide magnet from position X to position Z to temporarily set the ZERO 4 00mA setpoint this step is verified by checking that the output is now at 4 00 mA Bring the l...

Страница 5: ...equired the unit s 4 ma and 20 ma outputs can be trimmed as follows 2 5 1 Setting 4 0 mA DAC Trim Enter the 4 mA DAC TRIM MODE by applying power to the unit while Magnet is at position Z Magnet at position Z will decrease the output at 0 01 mA intervals Moving the magnet to position S will increase the output at 0 01 mA intervals Continue to Increase Decrease the output until the output is at 4 00...

Страница 6: ...NT DAC 01 mA SW Z DECREMENT DAC 01 mA POWER UP SW Z ENTER 4 0 mA DAC TRIM MODE SW S INCREMENT DAC 01 mA SW Z DECREMENT DAC 01 mA POWER UP SW X ENTER ALARM MODE SETUP SW S SET 21 mA ALARM SW Z SET 3 6 mA ALARM POWER UP SW X 2 sec ENTER CALIBRATION MODE SW S SET 20 mA 100 POINT SW Z SET 4 mA 0 POINT NORMAL OPERATION Magnetic switchpoints are located on lines S X Z at points 90 degrees from the condu...

Страница 7: ...ted a loss of signal no float detected problem with the configuration or a malfunc tion will cause the output to be set to the alarm condition of 3 6 mA 3 2 Output Stability If the current output occasionally jumps up or down but not to an alarm condition This can be an indication of noise or grounding problem Field wiring should be run with an individually shielded cable Insure that the transmitt...

Страница 8: ...AT500 0200 1b 10 2010 DCN0528 8 4 APPENDIX A 4 1 Installation Drawings ...

Страница 9: ...AT500 0200 1b 10 2010 DCN0528 9 4 1 Installation Drawings continued ...

Страница 10: ...AT500 0200 1b 10 2010 DCN0528 10 5 APPENDIX B 5 1 ...

Страница 11: ...er alterations misuse abuse improper or inadequate adjustments applications or servicing of the product K TEK s warranty does not include onsite repair or services Field service rates can be supplied on request If a product is believed to be defective the original purchaser shall notify K TEK and request a Returned Material Authorization before returning the material to K TEK with transportation p...

Страница 12: ...AT500 0200 1b 10 2010 DCN0528 12 6 2 RMA Form ...

Страница 13: ...AT500 0200 1b 10 2010 DCN0528 13 6 3 EU Declaration of Conformity ...

Страница 14: ...AT500 0200 1b 10 2010 DCN0528 14 ...

Отзывы: