![ABB JSHD4 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/abb/jshd4/jshd4_original-instructions-manual_2734009.webp)
2TLC172072M0201, rev. F
9
www.abb.com/jokabsafety
2018-06-01
Electrical connections
– AD
Note: 8-pin M12 male connector with internal connection suitable for safety relays in the RT series and Pluto safety
PLC. A jumper must be connected between pins 14-16 on 2 x 8 Molex connectors if no anti-cheat-board is used.
Electrical connections
– AE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
Male pin in 2 x
8 Molex male
8-pin M12 male
connector
Bottom part
– AD:
8-pin M12 male connector
1 ) S2
– Common
2 ) S1, S3, S4
– Common*
3 ) S3
– Enabled
4 ) S4
– Enabled
5 ) S1
– Enabled
Anti-cheat
– Common
6 ) S2
– Enabled
7 ) 0 VDC (anti-cheat, LED 1, LED 2)
8 ) Anti-cheat
– Operator detected
Extra jumper.
Required if no anti-
cheat-board is used
M12 8-pin male
connector seen
from the cable side
M12 8-pin male
connector seen
from the cable side
* Note: The COM signal must be +24 VDC to allow the LEDs
and anti-cheat-board to function properly.
1
2
3
4
5
6
7
8
9
10
11
12
14
13
15
16
1
2
3
4
5
6
7
8
Male pin in 2 x
8 Molex male
8-pin M12 male
connector
Bottom part
– AE:
8-pin M12 male connector
1 ) S2
– Common
2 ) S1
– Common*
3 ) S2
– Enabled
0 VDC (LED 1, LED 2)
4 ) S1
– Enabled
5 ) E1 (Emergency stop, channel 1)
6 ) E1 (Emergency stop, channel 1)
7 ) E2 (Emergency stop, channel 2)
8 ) E2 (Emergency stop, channel 2)
M12 8-pin male
connector seen
from the cable side
M12 8-pin male
connector seen
from the cable side
* Note: The COM signal must be
+24 VDC to allow the LEDs to
function properly.
5
7
8
6
13
15
14
16
13
15
14
16
Emergency stop
Note: Connect the
cables from the
emergency stop to the
connector on the top
part.