1.4 Load diagrams
1.4.1 Introduction to load diagram
Information
WARNING
It is very important to always define correct actual load data and correct payload
of the robot. Incorrect definitions of load data can result in overloading of the
robot.
If incorrect load data and/or loads are outside load diagram is used the following
parts can be damaged due to overload:
•
ball screw spline unit
•
motors
•
gearboxes
•
mechanical structure
WARNING
In the robot system is the service routine LoadIdentify available, which allows
the user to make an automatic definition of the tool and load, to determine correct
load parameters. For detailed information, see
Operating manual - IRC5 with
FlexPendant
.
WARNING
Robots running with incorrect load data and/or with loads outside diagram, will
not be covered by robot warranty.
General
The load diagram includes a nominal pay load inertia, J
0
of 0.01 kgm
2
. At different
moment of inertia the load diagram will be changed. For robots that are allowed
tilted, wall or inverted mounted, the load diagrams as given are valid.
20
Product specification - IRB 910SC
3HAC056431-001 Revision: G
© Copyright 2016-2020 ABB. All rights reserved.
1 Description
1.4.1 Introduction to load diagram
Содержание IRB 910SC
Страница 1: ...ROBOTICS Product specification IRB 910SC ...
Страница 2: ...Trace back information Workspace 20C version a3 Checked in 2020 09 14 Skribenta version 5 3 075 ...
Страница 6: ...This page is intentionally left blank ...
Страница 50: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 54: ......
Страница 55: ......