3 Maintenance
3.3.10. Inspection, additional mechanical stops
117
3HAC027151-001 Revision: B
©
Co
py
rig
h
t 200
6-
200
8 ABB. All righ
ts reser
v
ed.
Inspection, mechanical stops
The procedure below details how to inspect the additional mechanical stops on axes 1and 3.
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and pneumatic
pressure supplies to the robot!
2. Check the
additional stops
on axes 1 and 3 for
damage.
Shown in the figure
.
3. Make sure the stops are properly attached.
Correct tightening torque, mechanical stop axis 1:
120 Nm.
4. If any damage is detected, the
mechanical stops
must be replaced!
Correct attachment screws (lubricated with Molycote
1000):
•
Axis 1: M12 x 40
•
Axis 3: M6 x 16
Art. no. is specified in
.