Note
Equipment, etc.
For spare part number, see
Spare Parts - Serial
measurement unit
.
Battery pack
The contents are defined in section
.
Standard toolkit
These procedures include references to the
tools required.
Other tools and procedures may be re-
quired. See references to these proced-
ures in the step-by-step instructions be-
low.
Replacement, battery pack
The procedure below details how to replace the battery pack in the serial
measurement unit.
Info/Illustration
Action
Step
xx0200000023
1
WARNING
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 32
Set the robot to the MOTORS OFF operating mode.
2
This way the robot does not need to be calibrated
after the battery change.
Shown in the figure
Remove the
rear cover plate
from the base.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
3
Loosen the battery terminals from the serial measur-
ing board and cut the clasps that keep the battery
pack in place.
4
Remove the old battery pack.
5
Fit a new
battery pack
with two clasps and connect
the terminals to the serial measuring board.
6
110
Product manual - IRB 4400
3HAC022032-001 Revision: Q
© Copyright 2004-2018 ABB. All rights reserved.
3 Maintenance
3.5.1 Replacing the SMB battery
Continued
Содержание IRB 4400/60
Страница 1: ...ROBOTICS Product manual IRB 4400 ...
Страница 2: ...Trace back information Workspace R18 1 version a9 Checked in 2018 03 22 Skribenta version 5 2 025 ...
Страница 8: ...This page is intentionally left blank ...
Страница 94: ...This page is intentionally left blank ...
Страница 282: ...This page is intentionally left blank ...
Страница 294: ...This page is intentionally left blank ...
Страница 296: ...This page is intentionally left blank ...
Страница 302: ......
Страница 303: ......