Note
Action
xx2200000035
Disconnect the connectors.
•
MP6
•
FB6
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The MP6 connector is fitted in particular position.
Handle with cautions to not get it stuck.
2
xx2200000033
Remove the axis-6 cable bracket.
CAUTION
Be aware of the cablings that are attached to the
cable bracket! The bracket cannot be removed
completely until the cablings are removed from
the plate.
3
xx2200000034
Cut the cable straps.
4
Pulling out the cable package from axis 5
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Wrap the connectors with the masking tape.
2
Continues on next page
Product manual - IRB 1010
267
3HAC081964-001 Revision: B
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.5.3 Replacing the axis-5 motor
Continued
Содержание IRB 1010
Страница 1: ...ROBOTICS Product manual IRB 1010 ...
Страница 2: ...Trace back information Workspace 22D version a9 Checked in 2022 12 16 Skribenta version 5 5 019 ...
Страница 8: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 46: ...This page is intentionally left blank ...
Страница 80: ...This page is intentionally left blank ...
Страница 306: ...This page is intentionally left blank ...
Страница 312: ...This page is intentionally left blank ...
Страница 326: ...This page is intentionally left blank ...
Страница 328: ...This page is intentionally left blank ...
Страница 332: ......
Страница 333: ......