Operation Manual / A130-H.. - A140-H..
9 Dismantling and fitting / 9.15 Installing the compressor casing
© Copyright 2021 ABB. All rights reserved.
HZTL4030_EN
Rev.G
July 2021
Installing the compressor casing
Fig. 54: Installing the compressor casing
*) In some installations a special graphite cord sealing (42126) is fitted instead of the O-
ring (42012) (see also chapter
).
Product
Size
Tightening torque [Nm]
A130
M8
35
A135
M10
70
A140
M12
105
Table 41: Tightening torque (72011)
1. Fit a new, high temperature-resisting O-ring (42012, red or green) (see chapter
customer spare part set (97070)
).
2. Thoroughly clean the fastening strips (72012) before assembly.
3. Attach swivel lifting eyes (01) to the compressor casing (72000) and lifting gear.
4. Install the compressor casing (72000).
5. Install the fastening strips (72012) with screws (72011).