Operation Manual / TPL76-C
3 Commissioning / 3.1 Oil supply
© Copyright 2018 . All rights reserved.
HZTL2485_EN
Revision F
April 2018
Lubricating oil temperature at the inlet
CAUTION
Machine damage
If the oil temperature at the oil inlet exceeds the admissible range, this
may lead to engine damage.
u
Observe oil temperature at the oil inlet according to the following
table.
Status for operation
Oil temperature at the in-
let
T
oil,inlet
[°C]
Admissible
30 … 80
Temporarily admissible (< 1 h) -> alarm
> 80
Not admissible -> stop engine
> 85
Not admissible -> do not start engine
(before start: preheat oil)
< 30
Lubricating oil temperature at outlet
The oil temperature at the outlet is mainly dependant on:
¡
Lubricating oil temperature and pressure at the oil inlet
¡
Engine load and turbocharger speed
¡
Exhaust gas temperature
The maximum admissible oil temperature at the outlet is listed in the fol-
lowing table. The specified oil outlet temperature is to be considered as
alarm value for the turbocharger operation and must be monitored ac-
cording to the current regulations.
Status for operation
Oil temperature at outlet
T
oil,outlet
[°C]
Permissible
≤
130
Temporarily permissible -> alarm
> 130
Not permissible -> stop engine
> 150
If the turbocharger was operated for a longer period of time outside of
the admissible range, ABB Turbo Systems recommends to have the tur-
bocharger inspected by an ABB Turbocharging Service Station.
Page
30
/
133