Operation Manual / TPL65-A32 / -A33 / -A36 + TPL69-A32 / -A33
6 Troubleshooting / 6.4 Malfunctions when stopping
© Copyright 2019 . All rights reserved.
HZTL2498_EN
Rev.D
August 2019
6.4 Malfunctions when stopping
Noises during run-down
Possible causes
Elimination
Turbochar-
ger
Turbocharger contaminated
Clean it
Damaged bearing
Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
Run-down time too short
Possible causes
Elimination
Turbochar-
ger
Turbocharger contaminated
Clean it
Damaged bearing
Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
Page
72
/
118