6.5.4
Wet cleaning of turbine and nozzle ring
Prerequisites
The following operating state and the following prerequisites have been tested and ap-
proved by ABB Turbo Systems for cleaning operations:
u
Set the engine load between 20 … 50 % so that the turbine inlet temperature is between
380 … 430 °C.
Fig. 23: Turbine and nozzle ring cleaning cycle
u
Once the turbine inlet temperature is stable and has dropped below 430 °C, wait at least
another 10 minutes to allow the turbine-end turbocharger parts to cool down.
u
Start the cleaning cycle according to the following description Wet cleaning procedure.
Procedure
Fig. 24: Procedure Wet cleaning of turbine and nozzle ring
The prerequisites and the operating state must be fulfilled prior to cleaning.
u
Make sure that the water supply (01) is connected, switched on and safeguarded.
u
Switch the 3-way valve (04) from scavenging air mode to water supply.