Operation Manual / 4 Product description / A100-M axial
8
Disassembly and assembly
Page 77 / 113
© Copyright 2016 ABB. All rights reserved.
HZTL4033_EN
Revision A
July 2016
8.9
Installing the cartridge group
CAUTION
Clearance between blade tip and casing
Serious damage to machinery or property can result from the rubbing or
jamming of the blade tips on the casing.
Check that the blades do not rub on the turbine diffuser during disassem-
bly/assembly by rotating the rotor.
Figure 47: Installing the cartridge group 1
1. Fasten lifting gear to bearing casing and lift cartridge group slightly.
2. Remove support (90450).
3. Using two guide rods (90490), carefully move in cartridge group.
4. Remove guide rods (90490).