Removing the air suction branch
Disconnect all air lines according to the instructions of the enginebuilder.
Dismantle insulation as far as necessary.
Figure 27: Removing / installing the air suction branch
1. Loop lifting gear around air suction branch.
2. Loosen and remove the nuts (72027) with washers (72028).
Remove and put down the air suction branch.
Installing the air suction branch
The installation of the air suction branch is carried out in reverse order.
Tighten nuts (72027) to the specified tightening torque.
Part number
A170-M
A175-M
27027
M18
170 Nm
M20
220 Nm
Table 31: Tightening torque (27027)