Operation Manual / 4 Product description / A100-M axial
6
Periodic maintenance
Page 38 / 113
© Copyright 2016 ABB. All rights reserved.
HZTL4033_EN
Revision A
July 2016
6.2
Cleaning the filter silencer
Figure 20: Cleaning the filter silencer (1)
81135 Filter silencer body
81266 Cover grid
81136 Absorption segment
81269 Connecting rods
81137 Sheet-metal covering
81272 Screw
81265 Filter ring (if present)
81273 Lock nut
E
Insert unit = absorption s sheet-metal covering
NOTICE
Disassembly and assembly
The disassembly and assembly of the filter silencer is described in chapter
Disassembly and assembly.
Cleaning the filter ring (if present)
Remove filter ring (81265).
Clean filter ring (81265) as required or every 500 hours of operation and replace after the
fifth cleaning process at the latest.
Contamination of the filter ring depends on the degree of purity of the sucked-in air.
Rinse the filter ring (81265) with water and mild detergent or, in the case of heavy contam-
ination, soak and carefully push through. Rinse in cold water. Avoid high mechanical loads
(water jet).
Let the filter ring dry completely before assembling.
Dirty water and mild detergent must be disposed of in compliance with locally applicable
regulations.