Operation Manual / TPS44-F.. - TPS61-F..
Troubleshooting
6
Malfunctions during operation
6.3
Page 81
Apr
il 20
15
H
ZT
L24
12_
EN
R
ev
is
ion E
Charge air pressure too low
Engine output and engine speed unchanged, air intake condition normal
Possible causes
Elimination
Engine
Air receiver leaky
Repair it.
Gas line between engine and
turbine leaky
Maladjusted injection system
Correct it.
Maladjusted valve control
Turbo-
charger
Manometer display wrong
Replace manometer.
Line to manometer leaky
Repair it.
Dirty filter silencer, causing
excessive loss of pressure
Clean it.
Dirty compressor / turbine
Damaged compressor / turbine Contact ABB Turbocharging
service station.
Exhaust counterpressure too
high
Clean or repair boiler or exhaust
silencer.
Charge-air pressure too high
Engine performance and engine speed unchanged, suction condition
normal
Possible causes
Remedy
Engine
Malfunction in the injection
system
Repair or contact manufacturer
Injection misaligned
Set correctly
Engine performance higher than
expected
Check engine performance
Turbo-
charger
Manometer display defective
Replace manometer
© Copyright 2015 ABB. All rights reserved.