1.3.2 Risks associated with live electric parts
Voltage related risks, general
Work on the electrical equipment of the robot must be performed by a qualified
electrician in accordance with electrical regulations.
Although troubleshooting may, on occasion, need to be carried out while the power
supply is turned on, the robot must be turned off (by setting the main switch to
OFF) when repairing faults, disconnecting electric leads, and disconnecting or
connecting units.
The main supply to the robot must be connected in such a way that it can be turned
off from outside the working space of the robot.
Make sure that no one else can turn on the power to the controller and robot while
you are working with the system. A good method is to always lock the main switch
on the controller cabinet with a safety lock.
The necessary protection for the electrical equipment and robot during installation,
commissioning, and maintenance is guaranteed if the valid regulations are followed.
Voltage related risks, IRC5 controller and spot welding cabinet
A danger of high voltage is associated with, for example, the following parts:
•
Be aware of stored electrical energy (weld timer in the spot welding cabinet,
DC link and Ultracapacitor bank unit) in the controller.
•
Units such as I/O modules, can be supplied with power from an external
source.
•
The main supply/main switch
•
The transformers
•
The power unit
•
The control power supply (230 VAC)
•
The rectifier unit (262/400-480 VAC and 400/700 VDC. Note: capacitors!)
•
The drive unit (400/700 VDC)
•
The drive system power supply (230 VAC)
•
The service outlets (115/230 VAC)
•
The customer power supply (230 VAC)
•
The power supply unit for additional tools, or special power supply units for
the machining process.
•
The external voltage connected to the controller remains live even when the
robot is disconnected from the mains.
•
Additional connections.
Voltage related risks, tools, material handling devices, etc.
Tools, material handling devices, etc., may be live even if the robot system is in
the OFF position. Power supply cables which are in motion during the working
process may be damaged.
16
Product manual - GWT C9
3HAA010198-001 Revision: A
© Copyright 2022 ABB. All rights reserved.
1 Safety
1.3.2 Risks associated with live electric parts
Содержание GWT C9
Страница 1: ...ROBOTICS Product manual GWT C9 ...
Страница 62: ...This page is intentionally left blank ...
Страница 124: ...This page is intentionally left blank ...
Страница 126: ......
Страница 127: ......