![ABB G13 Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/abb/g13/g13_user-manual_3573096.webp)
2CMC489001M0201
92
G13
Revision: A
User Manual
JSON Communication
Response
•
200 Success
HTTP/1.1 200 OK
X-Frame-Options: sameorigin
X-Xss-Protection: 1; mode=block
Content-Type: text/html;charset=utf-8
Content-Length: 20
Connection: Keep-Alive
{"status":"success"}
• 400 Bad Request
HTTP/1.1 400 Bad Request
Server: embOS/IP
Accept-Ranges: bytes
Content-Length: 57
Content-Type: application/json
{
"status":"error",
"des":"missing name and key tag in JSON ."
}
•
500 Internal Server Error
HTTP/1.1 500 Internal Server Error
Server: embOS/IP
Accept-Ranges: bytes
Content-Length: 64
Content-Type: application/json
{
"status":"error",
"des":"received invalid response from COSEM."
}
6.3.28 GET /parametermapping
A GET call to /parametermapping returns the mapping list to be used as a refer-
ence for configuring parameters in other URIs like configuration of complex pa-
rameters.
Protected