![ABB FSE-31 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/abb/fse-31/fse-31_user-manual_2725030.webp)
30 Diagnostics
LEDs
The FSE-31 module has three diagnostic LEDs.
Safety encoder fault reaction
The FSE-31 module indicates the internal faults of the safety
encoder as cabling faults.
The fault reaction depends on the FSO-21 module parameter
settings. For more information, see
FSO-21 safety functions
module user's manual
(3AXD50000015614 [English]).
FSE-31 module replacement
For instructions about replacing the FSE-31 module, see
FSO-21
safety functions module user's manual
(3AXD50000015614
[English]).
Name
Color
Description
PWR
Green
The module is powered up.
ENC STATUS
Green
The encoder is in normal operation.
Off
An encoder fault is active.
STATUS
Green
The module is in normal operation.
Green flashing
The module is initializing.
Off
A module fault is active.