13 Transmitter LED Information
Normal operation
#
LED indication
Name of LED
Colour
1
Green
2
Yellow
3
Green
4 Not used
Red
5
Yellow
1
2
3
4
5
Description
1
Normal operation, long range selected
2
Normal operation, short range selected
Error conditions
#
LED indication
Name of LED
Colour
1
Green
2
Yellow
3
Green
4 Not used
Red
5
Yellow
1
2
3
4
5
Description of error
Corrective action
1
Low voltage
Check power supply (24 VDC ± 20%)
2
º º
Control logic fault
Check that change-over switch bank 1
and bank 2 are equal.
Remove and reapply power. If error is
still present, contact your local ABB AB
JOKAB SAFETY distributor.
3
º
Error on range selection
Check the setting of the switches for the
range selection