Endura AZ40 | Oxygen and carbon monoxide equivalent (COe) analyzer |

COM/AZ40/MOD–EN Rev. A

7

3 Communication level

The 

Communication

 level is accessed from the 

Advanced

 

access level. To access the communication level and the 
configuration parameters for the communications module 
fitted:

1.

Press the 

 key (below the 

 icon on any 

Operator

 

page).

The 

Operator 

menu is displayed:

2.

Press the 

 key to scroll to 

Enter Configuration

 and 

press the 

 key.

The 

Access Level

 page is displayed:

3.

Use the 

 key to scroll to 

Advanced

 and press the 

 

key (below the 

Select

 prompt).

4.

Use the 

 and 

 keys to scroll to the 

Communication

 

level: 

5.

Press the 

 key (below the 

Select

 prompt).

The 

Communication

 page appropriate to the 

communication module fitted is displayed:

MODBUS – refer to Section 4, page 8.

IMPORTANT (NOTE)

 

Communication

 level menus are 

enabled only if an optional communications module is 
fitted and the parameters displayed are specific to the 
type of module fitted. For example, if a MODBUS 
module is fitted, MODBUS parameters are enabled, but 
Ethernet parameters are neither enabled nor displayed.

25.0

0.06

97

0.0

CAL

2015-04-09

14:33:12

°C

%

%

%

AZ40

Oxygen

Combustibles

Outlet Temp.

Efficiency

25.0

0.06

97

0.0

CAL

2015-04-09

14:33:12

°C

%

%

%

Operator Pages

Data Views
Logs
Alarm Acknowledge
Autoscroll
Enter Configuration

AZ40

Oxygen

Combustibles

ency

Access Level

Back

Select

Read Only

Calibrate
Advanced
Service

Menu

Communication

Exit

Select

Communication

MODBUS

Back

Select

Содержание Endura AZ40

Страница 1: ...s together with MODBUS reference tables for the Endura AZ40 analyzer For more information Further publications for the Endura AZ40 analyzer are available for free download from www abb com analytical...

Страница 2: ...f specification alarms 10 A 1 6 Transmitter and sensor diagnostic maintenance alarms 10 A 1 7 Media card diagnostics 11 A 1 8 Relay state diagnostics 11 A 1 9 Alarm state diagnostics 11 A 2 Digital ou...

Страница 3: ...re injury WARNING Bodily injury High temperature This symbol in conjunction with the signal word WARNING indicates a potentially dangerous situation Failure to observe this safety information may resu...

Страница 4: ...tested half mask conforming to EN140 or equivalent with a level 3 particulate filter conforming to EN 143 or equivalent Disposable protective coveralls in accordance with Type 5 ISO 13982 1 2004 or e...

Страница 5: ...btained from the Company together with servicing and spares information WARNING Bodily injury The transmitter weighs 7 6 kg 17 lb and must be mounted in accordance with the information supplied in the...

Страница 6: ...c disposal systems after 12 August 2005 To conform to European local and national regulations EU Directive 2002 96 EC European electrical equipment users must now return old or end of life equipment t...

Страница 7: ...below the Select prompt The Communication page appropriate to the communication module fitted is displayed MODBUS refer to Section 4 page 8 IMPORTANT NOTE Communication level menus are enabled only if...

Страница 8: ...transmitter on a MODBUS link RS485 Setup Mode Select the MODBUS serial communication serial link type 2 Wire 4 Wire or Off 4 Wire Baud Rate Select a communication transfer rate 1200 2400 4800 9600 19...

Страница 9: ...tions Make connections to the MODBUS serial board as shown in Fig 4 1 On systems with multiple slaves make connections to two or four wire link configurations in parallel as shown in Fig 4 2 When conn...

Страница 10: ...ocouple failed 6 28 Sensor non volatile memory failed 7 29 Processor board non volatile memory failed 8 30 Main board non volatile memory failed 9 31 Reserved 10 32 Reserved 11 33 Comms board non vola...

Страница 11: ...15 Acknowledge alarm 8 MODBUS address Description 30000 Oxygen concentration value 30002 COe concentration value 30004 Inlet temperature value 30006 Outlet temperature value 30008 Outlet Inlet tempera...

Страница 12: ...rature MODBUS address Description 30100 Calibration progress completion MODBUS address Description 30102 Analog output value mA AOUT1 30104 Analog output value mA AOUT2 30106 Analog output value mA AO...

Страница 13: ...w 40048 Analog output 3 Electrical range high 40050 Analog output 3 Electrical range low 40052 Analog output 3 Engineering range high 40054 Analog output 3 Engineering range low 40056 Analog output 4...

Страница 14: ...couple types 43006 Efficiency calculation 0 Disabled 1 Enabled 43007 Blowback interval 0 Off 1 24 hours 43008 Reserved 43009 Scheduled calibration frequency units 1 Off 1 Daily 2 Weekly 3 Monthly 4301...

Страница 15: ...ht saving 1 First 5 Last 2 Second 3 Third 4 Fourth 43034 Daylight saving end day for daylight saving 1 to 7 where 1 Sunday and 7 Saturday 43035 Daylight saving end month for daylight saving 1 to 12 wh...

Страница 16: ...rrent enable 0 Disabled 1 Enabled 43061 Analog output 4 Source 0 None 6 Efficiency 43062 Analog output 4 Polarity 0 Inverted 1 Non Inverted 43063 Analog Output 4 Failure current enable 0 Disabled 1 En...

Страница 17: ...ag Alarm 1 44096 Alarm 2 tag Alarm 2 44112 Alarm 3 tag Alarm 3 44128 Alarm 4 tag Alarm 4 44144 Alarm 5 tag Alarm 5 44160 Alarm 6 tag Alarm 6 44176 Alarm 7 tag Alarm 7 44192 Alarm 8 tag Alarm 8 MODBUS...

Страница 18: ...18 COM AZ40 MOD EN Rev A Endura AZ40 Oxygen and carbon monoxide equivalent COe analyzer Appendix B Acknowledgements MODBUS is a registered trademark of the Modbus IDA organization...

Страница 19: ...Endura AZ40 Oxygen and carbon monoxide equivalent COe analyzer COM AZ40 MOD EN Rev A 19 Notes...

Страница 20: ...document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior writt...

Отзывы: