2 Installation
2.2.5. Fitting the attachments of IRBDP SW5 CE (SpotPack Basic)
3HAC027309-001 Revision: D
64
©
Co
py
rig
h
t 200
6-
201
0 ABB. All righ
ts reser
v
ed.
Fitting cable attachments - upper end
This procedure describes how to install the attachments at the upper end of the cable package
(SpotPack basic).
Action
Note
1.
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots:
Do not turn off the air pressure to motors and
SMB.
2. Fit the
adjustable bracket
to the
axis 3 bracket
with its
brackets
and attachment screws.
Lock screws with
locking liquid
.
Locking liquid is specified in
xx0800000076
Parts:
•
A: Adjustable bracket
•
B: Bracket
•
C: Axis 3 bracket
Continued