4 Repair
4.2.2. Replacement of cable package IRBDP MH2 CEandIRBDP SW2 CE
3HAC027309-001 Revision: D
176
©
Co
py
rig
h
t 200
6-
201
0 ABB. All righ
ts reser
v
ed.
14. Open the
ball joint housing
on the
tension
arm unit
, and remove the cable package.
xx0600003180
Parts:
•
A: Ball joint housing
•
B: Tension arm unit
15. Open the upper and lower
gripping clamps
on the lower arm and remove the cable
package.
xx0600003170
Parts:
•
A: Bracket lower arm
•
B: Gripping clamp
•
C: Attachment screws, bracket
M10x16 quality 8.8 (2 pcs)
•
D: Process cable package
•
E: Lower arm
•
F: Attachment screws, gripping
clamp M8x16 quality 8.8 (2 + 2
pcs)
•
G: Washer 2 holes
16. Fit the new or repaired cable package.
Detailed in section,
package IRBDP SW2 CE IRBDP MH2
CEand on page 67
Action
Note
Continued