Chapter 5 - Parameters and Signals
DCS 500 12-Pulse Planning and Start-Up
5 - 1
Group 12: New parameters (existing group)
OPER_SYS:
Operating mode selection
0 = 6-pulse single (default)
1 = 12-pulse MASTER
2 = 12-pulse SLAVE
1209
P: I2
SC: NUM
HL: 2
LL: 0
D: 0
U: -
Group 111: New signals (existing group)
FAULT_WORD_3
B0 -01- Reversal Fault
B1 -02- Current difference
B2 Reserve
B... Reserve
B15 Reserve
11103
S: PB
SC:
read only
Group 36: 12-pulse (new)
REV_DELAY
- Bridge reversal delay (number of cycles: 3.3 ms at 50 Hz)
- Also operative in 6-pulse mode
- Must have the same setting at Master and Slave
3601
P: U2
SC: NUM
HL: 200
LL: 0
D: 0
U: -
REV_GAP
- Number of cycles which prevent a bridge reversal when the bridges have different actual
currents. After this, a bridge reversal function will be executed irrespective of the partner
unit.
- Must have the same setting at Master and Slave
3602
P: U2
SC: NUM
HL: 50
LL: 0
D: 0
U: -
FREV_DELAY
- Number of cycles which must be waited in the event of differently fired bridges until Error
65 is triggered
- Must have the same setting at Master and Slave
- Must be greater than the sum of 3601 and 3602
3603
P: U2
SC: NUM
HL: 250
LL: 1
D: 10
U: -