background image

19

Display

0

xxxx

1

xxx . x

2

xx . xx

3

x . xxx

4

x . xxxx

Display

Relay 1

Relay 2*

Relay 3*

Logic Output

Analog Output

50Hz 60Hz

Source

Source

Source

Source

Source

1

A

Alarm 1

Alarm 2

Alarm 3

IPFAIL

ML

2

b

Alarm 1

Alarm 2

Alarm 3

IPFAIL

ML average

         

U

Custom

Custom

Custom

Custom

Custom

A 1

200

A – Hardware Configuration

ML = Measured level

IPFAIL = Measured level failure

* only available if the appropriate option board is fitted

1

2

00

B – Input Type and Range Configuration

12

0

0

D –  Process Variable

Display Decimal
Places

120

0

C – Not Applicable

Display

2

4 to 20 mA

8

1 to 10mA (P851, P861 sensor)

U

Custom configuration

4

CONFIGURATION MODE…

Fig. 4.2 Hardware Configuration and Input/Output Ranges

…4.3.1

Hardware Assignment and Input Type – Fig. 4.2

Содержание DATUM L150

Страница 1: ...InformIT 1 8 DIN Level Indicator User Guide IM L150_7 L150...

Страница 2: ...stored away from heat protected from temperature extremes and powders kept dry Normal safe handling procedures must be used 6 When disposing of chemicals ensure that no two chemicals are mixed Safety...

Страница 3: ...and 4 Accessing the configuration levels Level 3 Hardware assignment and input type Alarm types and hysteresis Operator functions Digital input and serial communications Level 4 Ranges and passwords I...

Страница 4: ...2 Operating Page Standard Function Level 1 8 2 3 Operating Page Max Min Average Functions Level 1 9 2 4 Operating Page Volume Function Level 1 11 3 SET UP MODE 12 3 1 Introduction 12 3 2 Set Up Level...

Страница 5: ...own during the start up procedure Displayed at startup for 3 seconds Software version and issue eg L150 2001 Issue 1 displayed for 3 seconds Display 1 DISPLAYS AND FUNCTION KEYS Fig 1 1 Front Panel Di...

Страница 6: ...EL1 100 1 CodE 0 Use to view a parameter setting or selection 123456 select individual characters in a frame or move between levels LEVEL1 LEVEL2 LEVELx 100 1 200 2 300 3 400 4 Press for a few seconds...

Страница 7: ...3 LED Alarms and Indicators 1 3 LED Alarms and Indicators Fig 1 3 LED Status All flashing Level indicator is in the configuration mode see Section 4 2 A1 A2 and A3 Flashes when Alarm is active off whe...

Страница 8: ...Converter fault The analog to digital converter is not communicating correctly Sensor input out of range Option board error Communications to the option board have failed Display To Clear Display Clea...

Страница 9: ...ed by the indicator functions which are selected during configuration of the instrument see Section 4 Note Only the operating frames relevant to the configured functions are displayed in Operator Mode...

Страница 10: ...ly UN ACK alarm unacknowledged ACK alarm acknowledged Specific Gravity This is the value of specific gravity currently being applied to the process variable display only Security Code Enter the passwo...

Страница 11: ...s only UN ACK alarm unacknowledged ACK alarm acknowledged Average Value This is the mean average value of the process variable since the average was reset To reset the average value select rSt Y then...

Страница 12: ...he minimum was reset To reset the minimum value select rSt Y then press the key rSt Y reset rSt n do not reset Specific Gravity This is the value of specific gravity currently being applied to the pro...

Страница 13: ...alarm acknowledged Specific Gravity This is the value of specific gravity currently being applied to the process variable display only Volume This is the current volume derived from the process varia...

Страница 14: ...m 3 Hysteresis Average Value Maximum Value Minimum Value Specific Gravity Offset Adjustment Security Code 0 to 9999 default factory set code 0 Level 1 Operating Level Correct Code CodE x 0AdJ 3 SET UP...

Страница 15: ...the key for a few seconds Alarm 1 Trip Point Alarm type A1 hP High level alarm A1 LP Low level alarm A1 HL Latched high level alarm A1 LL Latched low level alarm A1 Fr Fast rate level alarm A1 Sr Slo...

Страница 16: ...s the mean average value of the process variable input since the average was reset To reset the average value select rSt Y then press the key rSt Y reset rSt n do not reset Continued on next page 1 No...

Страница 17: ...minimum value of the level input since the minimum was reset To reset the minimum value select rSt Y then press the key rSt Y reset rSt Y do not reset Specific Gravity Enter the specific gravity of t...

Страница 18: ...shown in Fig 4 1 Level 3 is divided into four frames For most simple applications it is only necessary to set up the parameters in the first frame Note When in the Configuration Level All the LED indi...

Страница 19: ...gineering Range Low Retransmission Range High Retransmission Range Low Volume Constant Set Up Password Configuration Password MODBUS Address Hardware Configuration Alarms and Set Points Level 3 K L 00...

Страница 20: ...er Parameter options are shown in Fig 4 2 A Hardware configuration b Input type and range C Not applicable d No of decimal points Note For custom settings contact the local distributor Continued on pa...

Страница 21: ...stom Custom A 1200 A Hardware Configuration ML Measured level IPFAIL Measured level failure only available if the appropriate option board is fitted b 1200 B Input Type and Range Configuration C 1200...

Страница 22: ...etter Parameter options are shown in Fig 4 3 E Alarm 1 type F Alarm 2 type G Alarm 3 type H Alarm hysteresis Note For fail safe operation active alarms denergize the relay and inactive alarms energize...

Страница 23: ...e 1 High Process 2 Low Process 3 High Latch 4 Low Latch 5 Fast Rate 6 Slow Rate F Alarm 2 Type Display 0 None 1 High Process 2 Low Process 3 High Latch 4 Low Latch 5 Fast Rate 6 Slow Rate Value in of...

Страница 24: ...arm hysteresis value of zero is configured the alarm becomes inactive when the process variable value returns past the alarm trip point value If a positive or negative hysteresis value is configured t...

Страница 25: ...ge per hour The elapsed time period before the alarm condition is detected is dependant upon the configured alarm value This period can be calculated as follows t 10 81 1800 trip value as a of eng spa...

Страница 26: ...s An alarm becomes active when the process variable value rises above the high latch alarm trip point value or falls below the low latch alarm trip point value The latch alarm trip point values are co...

Страница 27: ...hs Reset Enable 4 3 3 Operator Functions Fig 4 7 JKLN Settings The first character J K L or N identifies the parameter to be changed indicated by a flashing letter Available parameter options are show...

Страница 28: ...R S or T identifies the parameter to be changed The current setting is indicated by a flashing letter Parameter options are shown in Fig 4 8 P Digital input function r Analog input filter S Serial co...

Страница 29: ...Reset 2 Front Panel Lockout 3 Alarm Acknowledge P Digital Input Function Display 0 0 seconds 1 1 second 2 2 seconds 5 5 seconds A 10 seconds B 20 seconds C 40 seconds D 60 seconds R Analog Input Filte...

Страница 30: ...rom anywhere in this level press the key for a few seconds Engineering Display Range High Value 100 0 metres 9999 to 99999 Low Value 0 0 metres 9999 to 99999 Retransmission Range Defines the engineeri...

Страница 31: ...ed to calculate the volume of liquid in a tank from the measured level 0 0 to 9999 9 Set Up Password The password enables access to the set up level Level 2 0 to 9999 Default factory set 0 Configurati...

Страница 32: ...not be used in a non industrial environment End of Life Disposal This instrument does not contain any substance that will cause undue harm to the environment It can therefore be safely considered as...

Страница 33: ...within the L150 Level System gives protection against induced voltage transients of up to 2kV In high humidity environments condensation must be prevented from entering any sensor vent breather tubes...

Страница 34: ...32 Sensor Close to Sensor Avoid Vibration At Eye Level Minimum 5 INSTALLATION Fig 5 2 Siting the Instrument General Requirements 5 2 Siting the Instrument Figs 5 2 and 5 3...

Страница 35: ...5 INSTALLATION Fig 5 3 Environmental Requirements 5 2 Siting the Instrument Figs 5 2 and 5 3 Warning Select a location away from strong electrical and magnetic fields If this is not possible particula...

Страница 36: ...11 7 1 0 28 96 3 78 48 1 89 Panel cut out 0 03 0 0 8 0 45 0 6 0 1 77 0 02 0 14 0 55 14 0 55 5 INSTALLATION Fig 5 4 Overall Dimensions 5 3 Mounting the Instrument Figs 5 4 and 5 5 The instrument is des...

Страница 37: ...g 5 4 Insert the instrument into the panel cut out Fit the retaining clamp over the instrument case Push the retaining clamp firmly against the panel 1 2 3 4 5 INSTALLATION Fig 5 5 Mounting Details 5...

Страница 38: ...nstrument conforms to Mains Power Input Insulation Category 2 Pollution Degree 2 EN601010 1 All connections to secondary circuits must have basic insulation After installation there must be no access...

Страница 39: ...6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 0V L N N C C N O Relay Output 2 N C C N O RS485 TX RS485 RX RS485 or Relay Output 3 N C C N O P871 881 P871 881 3V Logic Output 18V at 20mA max 3V...

Страница 40: ...elays 2 and 3 only If relay 1 is required to switch inductive loads fit the arc suppression components supplied 5 5 3 Logic Output 18V DC at 20mA Minimum load 900 Isolation 500V from input not isolate...

Страница 41: ...eight 14mm 0 56 in Configuration User defined via front panel or PC configurator Standard Functions Alarms Number Three user defined Types High Low process High Low latch Fast Slow rate Alarm hysteres...

Страница 42: ...r input not isolated from logic output Logic output 18V DC at 20mA Min load 400 Isolation 500V from sensor input not isolated from retransmission output Relay output One relay as standard SPDT 5A at 1...

Страница 43: ...baud rate Protocol Modbus RTU slave Electrical Voltage supply 85 to 265V AC 50 60Hz 24V DC optional Power consumption 6VA 85 to 265V AC 5W 24V DC Power interruption protection 60ms 3 cycles no effect...

Страница 44: ...H non condensing Temperature stability 0 02 of reading or 2 V C 1 V F Front face IP65 NEMA 3 case rear IP20 EMC Emissions Meets requirements of EN50081 2 Immunity Meets requirements of EN50082 2 Desig...

Страница 45: ...the equipment referred to in this manual must be stored in a clean dry environment in accordance with the Company s published specification Periodic checks must be made on the equipment s condition I...

Страница 46: ...St Neots Cambridegshire PE19 8EU UK Tel 44 0 1480 475 321 Fax 44 0 1480 217 948 ABB Inc 125 E County Line Road Warminster PA 18974 USA Tel 1 215 674 6000 Fax 1 215 674 7183 ABB has Sales Customer Sup...