background image

23

9 System settings

CP600-eCo control panels

 have a system settings interface to allow configuration of system options.

System settings

The user interface of System Settings is based on HTML pages accessible locally on CP600 or in 

remote using a Web browser Chrome v44 or higher on port 443 (https://IP/machine_config). Default 

username is “admin”, default password is “admin”. Use navigation menu on the left side of the screen 

to browse through the available options.

The active item of menu is highlighted on the left side. The right side shows related information and 

settings. Based on the size of the CP600 screen, both menu and content of selected item may be 

shown on screen or not.

System Settings has two modes of operation: 

User Mode

 

PB610-B runtime is running or the CP600 device is in “factory default” status.

System Mode

  PB610-B runtime is not running or the CP600 device has a software failure. 

 

 

System Mode includes all options available in User Mode and offers in additions   

 

 

commands dedicated to system upgrade and recovery not availables when running in  

  User 

Mode.

Содержание CP600-eCo

Страница 1: ... OPER ATING INSTRUCTION Control Panels CP600 eCo CP604 B CP607 B CP610 B ...

Страница 2: ...ons 7 4 Technical data 9 4 1 Dimensions 11 4 2 Installation environment 14 4 3 Installation procedure 15 5 Connections 16 5 1 Serial port 19 5 2 Ethernet port 20 6 Power supply grounding and shielding 21 7 Cleaning faceplates 22 8 Getting started 22 9 System settings 23 10 Touchscreen calibration 25 11 Unpacking and packing Instructions 25 ...

Страница 3: ...anspor tation storage assembly use and maintenance The Manual refers to the following models CP604 Control panel with TFT color 4 3 widescreen display touchscreen CP607 Control panel with TFT color 7 widescreen display touchscreen CP610 Control panel with TFT color 10 1 widescreen display touchscreen Introduction ...

Страница 4: ...ls of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure to observe safety rules and that deficiency may cause damage CAUTION indicates a failure to observe safety rules and that deficiency may cause defects to the equipment or inconsistencies CAUTION ATTENTION DANGER Safety guide ...

Страница 5: ...jects Multilanguage applications with TrueType fonts Easily create install and maintain applications in multiple languages to meet global requirements Data display in numerical text bargraph analog gauges and graphic image formats Rich set of state of the art CP600 features data acquisition and logging trend presentation alarm handling scheduler and timed actions daily and weekly schedulers except...

Страница 6: ... allo wed only in the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 In compliance with the above regulations the products are CE marked Product identification The product may be identified through a plate attached to the rear cover You will have to know the type of unit you are using for correct usage of the information contained in the guide CP607 product m...

Страница 7: ...ontrol panel installed in a solid panel has been tested using conditions equiva lent to the standards shown in the Environmental conditions Even though the level of resistance of the control panel is equivalent to these standards oils that should have no effect on the CP600 can possibly harm the unit This can occur in areas where either vaporized oils are present or where low viscosity cutting oil...

Страница 8: ...eness may be present Solvent resistance Contact for 1 2 hour at 21 C No visible effect Acetone Butyl Cellosolve Cyclohexanone Ethyl Acetate Hexane Isopropyl Alcohol MEK Methylene Chloride Toluene Xylene Contact for 24 hours at 49 C No visible effect Coffee Ketchup Lemon Juice Mustard slight yellow stain Tea Tomato juice Touchscreen reliability 1 milion operations Note 1 Extended use in environment...

Страница 9: ... 60 MB Flash RAM 256 MB DDR 256 MB DDR Serial Port RS 232 RS 485 RS 422 software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 10 100 Mbit 10 100 Mbit USB port Host interface V2 0 max 500mA Host interface V2 0 max 500mA Real Time Clock yes yes Voltage 18 32Vdc 18 32Vdc Current rating at 24VDC 0 25A 0 30A Weight 0 4 Kg 0 6 Kg 4 Technical data Technical data ...

Страница 10: ... inches 10 1 widescreen Dimming yes User memory 60MB Flash RAM 512 MB DDR Serial Port RS 232 RS 485 RS 422 software configurable Ethernet port 10 100 Mbit USB port Host interface V2 0 max 500mA Real Time Clock yes Voltage 18 32Vdc Current rating at 24VDC 0 38A Weight 1 Kg Technical data ...

Страница 11: ...11 MODEL A B L H D T CP604 136mm 5 35 96mm 3 78 147mm 5 78 107mm 4 21 29mm 1 14 5mm 0 19 4 1 Dimensions Technical data Cut out Fig 4 1 ...

Страница 12: ...12 MODEL A B L H D T CP607 176mm 6 90 136mm 5 35 187mm 7 36 147mm 5 79 29mm 1 14 5mm 0 19 Technical data Cut out Fig 4 2 ...

Страница 13: ...13 MODEL A B L H D T CP610 271mm 10 66 186mm 7 32 282mm 11 10 197mm 7 75 29mm 1 14 6mm 0 23 Cut out Fig 4 3 Technical data ...

Страница 14: ...t sunlight This might accelerate the aging process of the front panel film The equipment is not intended for installation in contact with corrosive chemical compounds Check the resistance of the front panel film to a specific compound before installation Do not use tools of any kind screwdrivers etc to operate the touch screen of the panel The IP66 is guaranteed only if max deviation from the plan...

Страница 15: ...4 3 Installation procedure Place the fixing brackets as shown in figure Fig 4 5 CAUTION Screw each fixing screw until the bezel corner gets in contact with the panel Tightening torque 75 Ncm Technical data ...

Страница 16: ...16 5 Connections 1 Serial Port 2 Ethernet Port 3 USB Port 4 Power Supply Fig 5 1 Connections CP604 ...

Страница 17: ...17 1 Serial Port 2 Ethernet Port 3 USB Port 4 Power Supply Fig 5 2 Connections CP607 ...

Страница 18: ...18 1 Serial Port 2 Ethernet Port 3 USB Port 4 Power Supply Fig 5 3 CP610 Connections ...

Страница 19: ...signals in the PLC port connector are RS 232 RS 422 RS 485 The serial port is software programmable Make sure you select the appropriate interface in the programming software The communication cable must be chosen for the type of device being connected It is highly recommended to use communication cable for AC500 eCo TK682 Order No 1SA P500982R0001 Connections SERIAL PORT RS 232 RS 422 RS 485 To o...

Страница 20: ...ernet port have two LED indicators for status Please see description below LED indicators Green Yellow ON OFF No LAN cable connected BLINK link active ON LAN cable connected with 100Mbit s link BLINK link active OFF LAN cable connected with 10Mbit s link ...

Страница 21: ...tter case connect to ground the power source common as shown in figure with a dashed line When using the floating power scheme note that the CP600 devices internally connects the power common to ground with a 1MΩ resistor in parallel with a 4 7nF capacitor The power supply must have double or reinforced insulation The suggested wiring for the power supply is shown in figure Power supply grounding ...

Страница 22: ...installed on a computer running Microsoft Windows There are two options to transfer a PB610 B application project to a CP600 device Ethernet Connect the CP600 device to the computer with an Ethernet network connection From PB610 Panel Builder choose the command Run Download to target You may have to ensure that the proper firewall policy has been configured in the computer to allow PB610 Panel Bui...

Страница 23: ...hrough the available options The active item of menu is highlighted on the left side The right side shows related information and settings Based on the size of the CP600 screen both menu and content of selected item may be shown on screen or not System Settings has two modes of operation User Mode PB610 B runtime is running or the CP600 device is in factory default status System Mode PB610 B runti...

Страница 24: ...hold few seconds selecting so RESTART CONFIG OS to boot in System Mode System Settings includes options for basic settings of the device Language Configure language used for System Setting menu only System show informations about platform status and timers like System on time backlight on time Logs enable persistent log for BSP and allows to export it Date Time change the device date and time incl...

Страница 25: ...ocedure at boot this procedure consists in tapping the surface of the touchscreen during the device power up phase Tapping frequency must be high You have to start tapping the touchscreen as soon as power has been applied to the device When the sequence has been recognized the system shows the message TAP TAP DETECTED 2 Release touch and wait few seconds until the message ENTERING SYSTEM SETTINGS ...

Страница 26: ...ges or modify the contents of this document without prior notice With regard to purchase orders the agreed particulars shall prevail ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third partie...

Отзывы: